Chapter 35 File Manager
Figure 29 atgo Debug Command
35.10 Restoring the Firmware
This procedure requires the NXC’s firmware. Download the firmware package from www.zyxel.com and unzip it. The firmware file uses a .bin extension, for example, "1.01(XL.0)C0.bin". Do the following after you have obtained the firmware file.
This section is not for normal firmware uploads. You only need to use this section if you need to recover the firmware.
1Connect your computer to the NXC’s port 1 (only port 1 can be used).
2The NXC’s FTP server IP address for firmware recovery is 192.168.1.1, so set your computer to use a static IP address from 192.168.1.2 ~192.168.1.254.
3Use an FTP client on your computer to connect to the NXC. For example, in the Windows command prompt, type ftp 192.168.1.1. Keep the console session connected in order to see when the firmware recovery finishes.
4Hit enter to log in anonymously.
5Set the transfer mode to binary (type bin).
6Transfer the firmware file from your computer to the NXC. Type put followed by the path and name of the firmware file. This examples uses put e:\ftproot\ZLD FW \1.01(XL.0)C0.bin.
Figure 30 FTP Firmware Transfer Command
7Wait for the file transfer to complete.
Figure 31 FTP Firmware Transfer Complete
234 |
| |
NXC CLI Reference Guide |
| |
|
|
|