Manual background

Prestige 2302 Support Notes

After you have configured the rules for the first filter set, view the filter rule summary in SMT menu 21.2.

 

 

 

Menu

21.2 - Filter Rules Summary

 

# A Type

 

Filter Rules

M m n

- -

----

---------------------------------------------

- - -

1

Y

IP

Pr=6,

SA=0.0.0.0, DA=0.0.0.0, DP=137

N D N

2

Y

IP

Pr=17,

SA=0.0.0.0, DA=0.0.0.0, DP=137

N D N

3

Y

IP

Pr=6,

SA=0.0.0.0, DA=0.0.0.0, DP=138

N D N

4

Y

IP

Pr=17,

SA=0.0.0.0, DA=0.0.0.0, DP=138

N D N

5

Y

IP

Pr=6,

SA=0.0.0.0, DA=0.0.0.0, DP=139

N D N

6

Y

IP

Pr=17,

SA=0.0.0.0, DA=0.0.0.0, DP=139

N D F

 

 

 

 

 

 

 

 

 

 

 

 

Apply the first filter set 'NetBIOS_WAN' in the 'Output Protocol Filter' field for the remote node setup.

Configure the second filter set 'NetBIOS_LAN' by entering 2 in the Filter Set field.

Rule 1-Source port number 137, Destination port number 53 with protocol number 6 (TCP)

Menu 21.2.1 - TCP/IP Filter Rule

Filter #: 2,1

Filter Type= TCP/IP Filter Rule

Active= Yes

IP Protocol= 6 IP Source Route= No

Destination: IP Addr= 0.0.0.0

IP Mask= 0.0.0.0

Port #= 53

Port # Comp= Equal

Source: IP Addr= 0.0.0.0

IP Mask= 0.0.0.0

Port #= 137

Port # Comp= Equal

38

All contents copyright (c) 2005 ZyXEL Communications Corporation.

Page 38
Image 38
ZyXEL Communications P-2302HW manual Prestige 2302 Support Notes