Powermate PM0103002 manual Maintenance, Service and Storage

Page 10

MAINTENANCE

GENERATOR: Brushes

The brushes in the generator should be inspected once every year for chips and cracks. Brushes should be replaced when they are worn to 1/4 inch (7mm).

NOTE: Replace brushes in sets only, never separately. Replace only with brushes specified in parts list. Other brushes may appear to be identical but may have completely different mechanical and electrical characteristics.

INSPECTING THE BRUSHES:

1.Remove 2 screws (A) and end cover (B).

2.Remove screw (C) holding the brush module (D).

3.Disconnect the red (+) and black (-) brush wires from the tabs.

4.Replace if worn to 1/4 inch (7mm).

5.Do not over tighten screw.

HEAT SHIELD:

Inspect to ensure that all heat shields and heat deflectors are intact and in place. Do not remove any parts or modify parts. Removing or modifying parts could cause serious damage to the unit.

ENGINE: Carburetor Icing

During the winter months, rare atmospheric conditions may develop which will cause an icing condition in the carburetor. If this develops, the engine may run rough, loose power, and may stall. Call Product Service for more information.

QUICK STARTING TIPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE:

If your unit has been sitting around for a long time period and is hard to start, try doing some of these easy steps before calling the Customer Hotline.

1.Check the oil level.

2.Replace the old fuel.

3.Change the spark plug.

4.Check the fuel lines. Make sure the fuel valve is open.

5.Check all generator parts for integrity.

6.Clean the Carburetor.

SERVICE AND STORAGE

INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may result. To eliminate hard starting, follow these instructions:

1.Run the generator at least 30 minutes every month.

2.Run the generator, then close the fuel shut-off valve and allow the unit to run until the engine stops.

3.Move the engine switch to the “OFF” position.

LONG TERM STORAGE

When the generator set is not being operated or is being stored more than one month, follow these instructions:

1.Replenish engine oil to upper level.

2.Run the generator, then close the fuel shut-off valve and allow the unit to run until the engine stops.

3.Move the engine switch to the “OFF” position.

4.After the unit has cooled, drain gasoline from fuel tank, fuel line and carburetor.

5.Pour about one teaspoon of engine oil through the spark plug hole, pull the recoil starter several times and replace the plug. Then pull the starter until you feel the piston is on its compression stroke and leave it in that position.

This closes both the intake and exhaust valves to prevent the inside of the cylinder from rusting.

6.Cover the unit and store in a clean, dry place that is well ventilated away from open flame or sparks.

NOTE: We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

English

10

Customer Hotline 1-800-445-1805

Image 10
Contents Call US First Table DES Matieres Table of ContentsIndice Safety Information Safety and Operation RulesSpark Arrester Determining Total WattageInstallation Operating VoltageBefore Operation Generator Features Control Panel Endbell 120 V, 20 Ampere ReceptacleHandle Installation Handle InstallationStarting the Engine Starting the UnitPRE-START Preparation Applying LoadMaintenance Service and StorageService Information Limited Warranty HOW to Order Replacement PartsSécurité Règles D’OPÉRATION ET DE SécuritéPARE-ÉTINCELLES Détermination DE LA Puissance Totale NécessaireVérifier LA Tension Mise EN Place DE Lappareil Avant DE Mettre EN MarcheProtection Avec Disjoncteur Différentiel Gfci LubrificationTableau de commande Couvre-enroulement Prise de 120 V, 20 a Caractéristiques DU Groupe Electrogene’INSTALLATION DE Poignée Pose DE LA PoignéeDémarrage DU Moteur Demarrage DE LappareilPréparatifs AU Démarrage Branchement DES AppareilsEntretien Usage ET EntreposageCommande DE Pièces DE Rechange Service ClienteleGarantie Limitée Reglas DE Seguridad Y DE Funcionamiento SeguridadApagachispas Como Determinar EL Vataje TotalInstalacion EL Requerimiento DE VoltajeLubricacion Antes DE LA OperacionPuesta a Tierra DEL Generador EL Sensor DEL Nivel Bajo DE AceiteCaracteristicas DEL Generador Protector de circuitoInstalación DE LA Manija Instalación DE LA ManijaArranque DEL Motor Arranque DEL UnidadPreparacion Antes DE Arrancar Como Aplicar UNA CargaServicio Poco Frecuente Servicio Y AlmacenamientoEscudo DE Calor Almacenamiento a Largo PlazoServicio AL Cliente Garantía Limitada Como Pedir LOS RepuestosCrankcase Assembly / Ensemble DU Carter / Conjunto DE Cárter Part Description Descripción QTY Part Description Descripción 0067084 Air filter cover assembly Couvercle Tapa 0067085 0067092 Muffler cover assembly Mounting Feet / Pieds DE Monter / Pies DE Montar Pramac America, LLC