Powermate PM0103002 manual Operating Voltage, Installation

Page 5

OPERATING VOLTAGE

CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.

A power line conditioner should be used when running one or more of the following solid state items:

Garage door openers

Kitchen appliances with digital displays

Televisions

Stereos

Personal computers

Quartz clocks

Copy machines

Telephone equipment

Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805.

INSTALLATION

To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.

To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.

If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.

Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.

To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.

Always follow local codes and regulations that apply to the installation of any item that concerns this product.

1.NFPA 70 - National Electrical Code.

2.NFPA 37 - Standard for Installation and Use of Stationary Combustible Engines.

3.Agricultural Wiring handbook of Farm Standby Electric Power.

English

5

Customer Hotline 1-800-445-1805

Image 5
Contents Call US First Indice Table of ContentsTable DES Matieres Safety and Operation Rules Safety InformationDetermining Total Wattage Spark ArresterOperating Voltage InstallationBefore Operation Control Panel Endbell 120 V, 20 Ampere Receptacle Generator FeaturesHandle Installation Handle InstallationPRE-START Preparation Starting the UnitStarting the Engine Applying LoadService and Storage MaintenanceHOW to Order Replacement Parts Service Information Limited WarrantyRègles D’OPÉRATION ET DE Sécurité SécuritéDétermination DE LA Puissance Totale Nécessaire PARE-ÉTINCELLESVérifier LA Tension Protection Avec Disjoncteur Différentiel Gfci Avant DE Mettre EN MarcheMise EN Place DE Lappareil LubrificationCaractéristiques DU Groupe Electrogene Tableau de commande Couvre-enroulement Prise de 120 V, 20 aPose DE LA Poignée ’INSTALLATION DE PoignéePréparatifs AU Démarrage Demarrage DE LappareilDémarrage DU Moteur Branchement DES AppareilsUsage ET Entreposage EntretienGarantie Limitée Service ClienteleCommande DE Pièces DE Rechange Seguridad Reglas DE Seguridad Y DE FuncionamientoComo Determinar EL Vataje Total ApagachispasEL Requerimiento DE Voltaje InstalacionPuesta a Tierra DEL Generador Antes DE LA OperacionLubricacion EL Sensor DEL Nivel Bajo DE AceiteProtector de circuito Caracteristicas DEL GeneradorInstalación DE LA Manija Instalación DE LA ManijaPreparacion Antes DE Arrancar Arranque DEL UnidadArranque DEL Motor Como Aplicar UNA CargaEscudo DE Calor Servicio Y AlmacenamientoServicio Poco Frecuente Almacenamiento a Largo PlazoComo Pedir LOS Repuestos Servicio AL Cliente Garantía LimitadaCrankcase Assembly / Ensemble DU Carter / Conjunto DE Cárter Part Description Descripción QTY Part Description Descripción 0067084 Air filter cover assembly Couvercle Tapa 0067085 0067092 Muffler cover assembly Mounting Feet / Pieds DE Monter / Pies DE Montar Pramac America, LLC