Powermate PM0103007 Starting the Unit, PRE-START Preparation, Starting the Engine, Applying Load

Page 10

STARTING THE UNIT

Gasoline is very dangerous.

Serious injury or death may result from fire caused by gasoline contacting hot surfaces.

1.Do not fill fuel tank with engine running.

2.Do not spill fuel while refilling tank.

3.Do not mix oil with gasoline.

4.Follow all instructions and warnings in the operator manual.

PRE-START PREPARATION

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.

This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.

STARTING THE ENGINE

1.Check oil level and fuel.

2.Disconnect all electrical loads from the unit.

3.Open fuel shut off valve.

4.Adjust choke as necessary.

5.Set the engine switch to the “ON" position.

6.Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke.

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.

Provide adequate ventilation for toxic exhaust gases and cooling air flow.

Do not start or run the generator in an enclosed area, even if door or windows are open.

Engines give off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

Do not apply heavy electrical load during break-in period (the first two to three hours of operations).

SHUTTING THE GENERATOR OFF

1.Remove entire electrical load.

2.Let the engine run for two minutes without load.

3.Move the engine switch to the “OFF” position.

4.Do not leave the generator until it has completely stopped.

5.Close the fuel shut off valve if the engine is to be put in storage or transported.

6.If a cover is used, do not install until unit has cooled.

7.If the generator will not be used again for an extended time period, refer to the SERVICE AND STORAGE section of this manual.

English

10

Customer Hotline 1-800-445-1805

Image 10
Contents Do not Return to Store AU Magasin LA TiendaTable DES Matieres Table of ContentsIndice Safety Information Safety and Operation RulesDetermining Total Wattage Spark ArresterKW = 1,000 watts Installation Operating VoltageBefore Operation Generator Features K D BDC Usage Generator Features DC UsageDC Circuit Protector Portability KIT Installation Starting the Engine Starting the UnitPRE-START Preparation Applying LoadPeriodic Maintenance MaintenanceInspecting the Brushes Service and StorageInfrequent Service Heat ShieldEngine Troubleshooting Engine Specifications Service Information Limited Warranty Pramac America, LLC Airport Road Box Kearney, NESécurité Règles D’OPÉRATION ET DE SécuritéPARE-ÉTINCELLES Détermination DE LA Puissance Totale NécessaireVérifier LA Tension Mise EN Place DE Lappareil Avant DE Mettre EN MarcheProtection Avec Disjoncteur Différentiel Gfci LubrificationPrise à verrouillage de 120/240 V, 30 a Tableau de commande Prise de 120 V, 20 aCaractéristiques DU Groupe Electrogene Protecteurs de circuitUtilisation de courant continu c.c Le Protecteur de Circuit de Courant ContinuLinstallation DE KIT DE Transport Démarrage DU Moteur Demarrage DE LappareilPréparatifs AU Démarrage Branchement DES AppareilsLA Bougie D’ALLUMAGE Entretien PériodiqueEntretien LE Type D’HUILEUsage ET Entreposage Depannage DU Moteur Caracteristiques DU Moteur Commande DE Pièces DE Rechange Service ClienteleGarantie Limitée Reglas DE Seguridad Y DE Funcionamiento SeguridadApagachispas Como Determinar EL Vataje TotalInstalacion EL Requerimiento DE VoltajeLubricacion Antes DE LA OperacionPuesta a Tierra DEL Generador EL Sensor DEL Nivel Bajo DE AceiteCaracteristicas DEL Generador Protector de circuitoUso de DC Caracteristicas DEL Generador USO DE DCProtector de Circuito de CC Instalacion DEL PIE Instalacion DEL Juego DE TransportInstalación DE LAS Ruedas Instalación DE LA ManijaArranque DEL Motor Arranque DEL UnidadPreparacion Antes DE Arrancar Como Aplicar UNA CargaBujia Mantenimiento PeriódicoMantenimiento Tipo DE AceiteEscudo DE Calor Servicio Y AlmacenamientoPara Revisar LAS Escobillas Servicio Poco FrecuenteDeteccion DE Fallos DEL Motor Especificaciones DEL Motor Servicio AL Cliente Garantía Limitada Como Pedir LOS RepuestosCustomer Hotline Customer Hotline Parts List / Liste DES Pièces / Lista DE Piezas PM0103007 Part Description Descripción QTYEngine Drawing / Schema DE Moteur / Diagrama DE Motor Emission System Warranty Limited Liability