Briggs & Stratton 10000 Watt manual Installation

Page 7

Installation

Equipment Description

This product is intended for use as an optional home generator system which provides an alternate source of electric power and to serve loads such as heating, refrigeration systems, and communication systems that, when stopped during any power outage, could cause discomfort or inconvenience. This product does not qualify for emergency standby as defined by NFPA 70 (NEC).

Customer Responsibilities

Read and follow the instructions given in the Operator’s Manual, especially the section regarding selecting essential circuits.

Follow a regular schedule in maintaining, caring for and using your home generator, as specified in the Operator’s Manual.

Installer Responsibilities

Read and observe the safety rules.

Install only an UL approved transfer switches that is compatible with the home generator.

Read and follow the instructions given in this Installation and Start-up Manual.

IMPORTANT: If operating the generator below 40°F, it is recommended that a battery and oil warmer be installed. If operating the generator below 32°F, a battery and oil warmer must be installed. Both items are available at your local servicing dealer.

Unpacking Precautions

The unit is shipped bolted to its mounting pad, ready for installation. Avoid damage from dropping, bumping, collision, etc. Store and unpack carton with the proper side up, as noted on the shipping carton.

caution

Installing the 15A fuse could cause the engine to start.

Observe that the 15 Amp fuse has been removed from the control panel for shipping.

DO NOT install this fuse until all plumbing and wiring has been completed and inspected.

Delivery Inspection

After removing the carton, carefully inspect the home generator for any damage that may have occurred during shipment.

IMPORTANT: If loss or damage is noted at time of delivery, have the person(s) making delivery note all damage on the freight bill and affix his signature under the consignor’s memo of loss or damage. If loss or damage is noted after delivery, separate the damaged materials and contact the carrier for claim procedures. Missing or damaged parts are not warranted.

Shipment Contents

The home generator is supplied with:

Home generator

Pre-attached mounting pad

One flexible hook-up pipe (meets UL 569 and CSA 8.3)

This installation and start-up manual

Operator’s manual

Installation checklist

Oil drain tray

Touch up paint

One spare 15A fuse

Roof hardware bag

2 Pole connector - 240V from house

10 Pole connector - Sensing and control wires

Remote LED indicator kit (red LED/plate/screws)

Required Items Supplied by Installer

Battery (must be 12VDC, AGM type with at least 350 CCA (cold cranking amps))

Image 7
Contents Watt Home Generator System Model Number Model Revision Serial Number Where to Find UsDate of Purchase Generator EngineTable of Contents Hazard Symbols and Meanings Safety RulesBRIGGSandSTRATTON.COM Page Never operate generator without protective housing or covers Installation Generator Location Home Generator LocationGeneral Location Guidelines Gaseous Fuel System Access CoversFuel and Electrical Inlet Locations Lifting the GeneratorBRIGGSandSTRATTON.COM Natural Gas LP Vapor Fuel ConsumptionLP Vapor Natural Transfer Switch Communication Use TxRx and TxRx System ConnectorsPole Connector Plug +12 Volt DC, .5 Amp Output Internal power supplyUtility Circuit Connection Fault Detection SystemGenerator AC Connection System Grounding the GeneratorInitial Start-up No Load Final Installation ConsiderationsFuel Supply System Fuel System SelectionAutomatic Operation Sequence Engine AdjustmentControls OperationInstallation Inspection Setting Exercise TimerWatt Número de Modelo Revisión Número de Serie Dónde encontrarnosFecha de compra Generador MotorSímbolos de Peligro y Significados Instrucciones importantes de seguridadInstalación Mandos UtilizaciónSímbolos de Peligro y Significados Conserve estas instruccionesAte para arriba el pelo largo y quite la joyería Tensión peligrosaNo modifique al generador en ninguna forma Instala el fusible se puede producir el arranque del motorInstalación Ubicación del Generador Ubicación del Sistema de Generador de DomésticoPautas Generales para la Ubicación del Generador Elevación del Generador Dimensiones de la Entrada para Electricidad y CombustiblePara desmontar la puerta de acceso Puertas de AccesoSistema de combustible gaseoso Para desmontar el techoSe debe contar también con una abertura para manómetro Vapor de Gas Dimensiones de la Cañería de CombustibleConsumo de Combustible Gas Natural Vapor de PLCableado para toma de 10 polos Conexiones de SistemaCableado para toma bipolar Salida de +12 V CC y 0,5 a Fuente de alimentación internaSistema de Detección de Fallas Sistema de Conexión de c.a. del GeneradorConexión a Tierra del Generador Interconexiones del Circuito de ControlAceite de Motor Consideraciones finales para la instalaciónSistema de Suministro de Combustible Selección del Sistema de Combustible62,5 Hz Arranque inicial sin cargaAjuste del Motor Instale el fusible de 15 Amperios en el panel de controlTemporizador de enfriamiento del motor MandosUtilización Secuencia de operación automáticaInspección posterior a la instalación Configuración del temporizador de prácticaManuel d’Installation et Démarrage Numéro de modèle Révision Numéro de série Où nous trouverDate d’achat Génératrice MoteurSymboles de Danger et Moyens Commandes FonctionnementDirectives de sécurité importantes Certains composants de ce produit ainsi que les Symboles de Danger et MoyensDirectives de sécurité importantes SécuritéTension dangereuse Avis Précautions Lors du Déballage Responsabilités de l’InstallateurDescription de l’équipement Responsabilités de l’AcheteurDégagement Autour de la Génératrice Emplacement du Génératrice d’état d’AttenteDirectives Générales Concernant l’Emplacement Installez l’unité à l’extérieur SeulementSoulèvement de la Génératrice Pour enlever le toit Pour installer la porte d’accès et le toitPortes d’Accès Le système de combustible gazeuxDe raccord de combustible, où a représente l’alimentation Est disponible à votre centre de service local’un manomètre. Afin de s’assurer que le moteur reçoit La pression de carburant adéquate pour fonctionnerGas Naturel Vapeur PL Consommation de CombustiblePropane Gaz Connexions de système Système de Détection des Pannes Interconnexions du Circuit de CommandeTableau de Commande du Système Mise à la Masse de la GénératriceHuile à Moteur Considérations pour l’installation finaleSystème d’Alimentation en Combustible Sélection du Système de CombustibleRéglage du Moteur Démarrage initial sans chargeRéglez l’interrupteur de système de la génératrice sur Auto Séquence de fonctionnement automatique CommandesCapteur de Prise en Charge de la Tension de Service FonctionnementRéglage de la minuterie de cycle d’exercice Vérification installation

10000 Watt specifications

Briggs & Stratton has long been synonymous with quality engines and power products, and their 10,000-watt generator continues to uphold that reputation. This robust generator is designed for both home and professional use, making it suitable for emergency backups and job site applications alike. Its impressive power output is one of its standout features, providing ample electricity to run essential appliances, tools, and electronics during outages or in remote locations.

One of the primary features of the Briggs & Stratton 10,000-watt generator is its durable engine. The generator is equipped with a powerful 420cc OHV engine, which is designed for reliable performance under heavy loads. This engine is built to last, thanks to its rugged construction and reliable cooling system, ensuring optimal performance even during extended operating periods.

An essential characteristic of this generator is its impressive runtime. With a 7-gallon fuel tank, it can run for up to 9 hours at a 50% load, providing an extended period of power without the need for constant refueling. The inclusion of a fuel gauge allows users to check the fuel level easily, ensuring that they remain informed about fuel availability during usage.

The generator comes with an array of outlets, including multiple 120V household outlets, a 120/240V twist-lock outlet, and a USB port, enabling users to connect various devices simultaneously. This range of output options provides versatility for users who may need to power multiple appliances at once, whether it be during a blackout or at a job site.

In terms of technology, the Briggs & Stratton 10,000-watt generator features a self-diagnostic tool that monitors its performance and alerts the user to any potential issues before they become significant problems. This proactive approach to maintenance helps ensure that the generator remains in peak operating condition.

Another notable technology is the integrated idle control feature, which automatically adjusts the engine speed based on the load requirement. This not only improves fuel efficiency but also reduces noise levels, making it less obtrusive during use.

Additionally, the generator features a compact design with sturdy wheels for easy transport. Its durable frame is built to withstand rugged environments, while the folding handles make setup and storage convenient. Overall, the Briggs & Stratton 10,000-watt generator is an excellent choice for those seeking reliable power in various settings, combining strength, efficiency, and user-friendly features.