Briggs & Stratton Generator Maintenance, Changing Engine Oil and Filter, Changing Oil

Page 22

Briggs & Stratton Power Products Home Standby Generator

Installation, Start-Up and Owner’s Manual

GENERATOR

MAINTENANCE

The generator warranty does not cover items that have been subjected to operator abuse or neglect.To receive full value from the warranty, the operator must maintain the engine as instructed in the engine owner’s manual.

IMPORTANT: Before performing any maintenance on the generator, be sure you follow all steps in “Servicing the System” on page 20.

Generator maintenance consists of keeping the unit clean. Operate the unit in an environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air louvers on the enclosure must not become clogged with snow, leaves, or any other foreign material.

Check the cleanliness of the unit frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior/interior surface.

NOTE: DO NOT use direct spray from a garden hose to clean generator.Water can enter the engine and generator and cause problems.

Changing Engine Oil and Filter

Remove the two screws from each plastic access cover and remove both access covers from the two sides of the generator enclosure.

Changing Oil

1.Place oil drain tube into approved container.

2.Push in and rotate oil drain fitting 1/4 turn counterclockwise. Slowly pull outward until oil starts draining (Figure 12). DO NOT pull oil drain fitting off engine.

Figure 12 — Oil Drain Fitting

4.Slide oil drain tube up into clamp on generator.

Changing Oil Filter

1.Place oil drain tray over tubing and slide it under oil filter (Figure 13).

Figure 13 — Changing Oil Filter with Oil Drain Tray

oil drain tray

2.Follow instructions given in engine owner’s manual for changing oil filter.

3.Remove oil drain tray from under oil filter and clean up any spilled oil.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

To fill your engine with oil:

Follow synthetic oil grade recommendation given in “Engine Oil” on page 16 and oil fill instructions given in engine owner’s manual.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

• Refer to engine manual for oil fill information.

• Damage to equipment resulting from failure to follow this instruction will void warranty.

3.When oil has drained, push oil drain fitting in and rotate 1/4 turn clockwise until it locks in place.

22

Image 22
Contents Installation Start-Up Table of Contents Do not dispose of battery in a fire Important Safety InstructionsOperate generator only outdoors Amp fuse Before working on the equipment Save These Customer Instructions Responsibilities Installer ResponsibilitiesInstallation Assistance IntroductionKnow Your Home Standby Generator BatteryOil Fill Know Your Control Panel AUTO/OFF/MANUALInstallation Procedures Owner OrientationLifting the Generator Shipment ContentsHome Standby Generator Location Essential Circuit Selection Essential CircuitsDevice Running Watts Removable Roof and Access Door Fuel Inlet DimensionsDisconnect Box Mounting Guidelines Gaseous Fuel System To Home Standby Fuel ConsumptionFrom Fuel LoadFuel Pipe Sizing 10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ftPhysical Properties Propane Natural Gas Fuel Comparison ChartWithdrawal Rate 32F 20F 10F 30F 40F Wire Connections Before Initial START-UPServicing the Battery Battery ConnectionCharging the Battery Fuel Supply SystemAutomatic Operation Sequence Fuel System SelectionInitial START-UP no Load Installation Inspection Setting Exercise TimerTo perform the Set Exercise procedure Automatic Operation SpecificationsFault Detection System Servicing the SystemNo LED Discharged Battery Number of LED Flashes Fault DescriptionReset Fault Detection System Engine Fail To StartChanging Oil Generator MaintenanceChanging Engine Oil and Filter Changing Oil FilterWhen Calling the Factory To Clean the GeneratorStorage Troubleshooting Problem Cause CorrectionBriggs & Stratton Power Products Home Standby Generator Schematic Wiring Diagram Exploded View Main Unit Description Parts List Main UnitOptional Accessories Not Illustrated Items Not IllustratedExploded View Enclosure Parts List Enclosure Exploded View Control Panel Parts List Control Panel ADAPTER, Mounting,Alternator Exploded View and Parts List AlternatorHARNESS,Wire DC Charge SCREW, M5 .8 x 10 TaptiteConsumer Use Years Years or YearManual de Instalación,Arranque y Propietario Tabla DE ContenidoSensor de Excitación de Tensión de la Compañía Advertencia PeligroPrecaución Los generadores producen un voltaje muy poderosoResponsabilidades DEL Cliente Conserve Estas InstruccionesIntroducción Responsabilidades DEL InstaladorDe Nivel de Aceite Conozca SU Generador DE ReservaEtiqueta del Motor Tapón de Llenado y Varilla Tapón de Llenado y Varilla de Nivel de Aceite PermiteDisyuntor Interruptor Conozca EL Panel DE ControlFusible de Fusible de 15 Amperios Protege los circuitos de control deOrientación Para EL Propietario Procedimientos DE InstalaciónElevación del Generador Contenido de la CajaUbicación del Generador de Reserva Selección de los Circuitos Fundamentales Circuitos FundamentalesDispositivo Vatiaje de Directrices de Montaje del Cuadro de Desconexión Dimensiones de la Entrada de CombustibleTecho y Puerta de Acceso Desmontables Sistema DE Combustible Gaseoso Advertencia El generador de reserva viene preparado de fábrica paraConsumo de Combustible Gas Natural Vapor de PLGas Natural peso específico = Dimensiones de la Cañería de CombustiblePropano Líquido PL peso específico = Propiedades físicas Propano Gas natural Cuadro de Comparación de CombustiblesTasa de consumo 32F 20F 10F 30F 40F Conexiones DE Cables Antes DEL Arranque InicialCargar la Batería Conexión de la BateríaSistema de Suministro de Combustible Servicio la BateríaArranque Inicial SIN Carga Selección DEL Sistema DE CombustibleSecuencia DE Operación Automática Inspección Posterior a LA Instalación Ajuste DEL Temporizador DE EjercicioTemporizador de enfriamiento del motor Sistema DE Detección DE EspecificacionesOperación Automática FallasNo se Enciende el LED Batería Descargada Cantidad de Destellos del LED Descripción de la FallaRestablecimiento del Sistema de Detección de Fallas Baja Presión de AceiteCambio del Filtro de Aceite Mantenimiento DEL GeneradorCambio del Aceite del Motor y del Filtro Cambio del AceitePara Limpiar el Generador AlmacenamientoSi Llama a la Fábrica Reparacion DE Averias Garantía Limitada Fonctionnement Automatique Manuel dInstallation, Démarrage et UtilisateurTable DES Matières Entretien DE LA GénératriceAvertissement NE touchez PAS les fils dénudés ou les boîtiers Conservez CES Instructions Responsabilités DE LinstallateurAide À Linstallation IntroductionFAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTE Filtre à Air Et Jauge dHuile Filtre à lHuile15 Ampères FAMILIARISEZ-VOUS Avec LE Tableau DE CommandeDisjoncteur Interrupteur Procédures Dinstallation Conseils AU PropriétaireContenu de la Boîte Emplacement du Génératrice d’état d’AttenteDirectives Générales Concernant lEmplacement Soulèvement de la GénératriceSélection des Circuits Essentiels Circuits EssentielsAppareil Watts Directives dAssemblage du Boîtier de Débranchement Dimensions de lOrifice dAdmission du CombustibleToit Amovible et Porte dAccès LE Système DE Combustible Gazeux Avertissement Le génératrice d’état d’attente a été réglé en usine pourConsommation de Combustible Gas Naturel Vapeur PLGaz Naturel densité = 0,65 Grosseur du Tuyau de CombustibleGaz de Pétrole Liquéfié GPL densité = 1,50 Charte de Comparaison des Combustibles Propriétés physiques Propane Gaz naturelRaccords DE Fils Avant LE Démarrage InitialRechargez la Batterie Branchement de la BatterieSystème dAlimentation en Combustible Entretien de la BatterieDémarrage Initial Sans Capteur de Prise en Charge de la Tension de ServiceSélection DU Système DE Combustible Séquence DE Fonctionnement AutomatiqueRéglage DE LA Minuterie DU Cycle Dexercice Vérification InstallationWarranty Registration Box Milwaukee,Wisconsin Minuterie de Refroidissement du MoteurSystème DE Détection DES Pannes CaractéristiquesFonctionnement Automatique Entretien du SystèmeAucun DEL Batterie déchargée Clignotements Du VoyantRéarmement du Système de Détection des Pannes Faible Pression dHuileChangement du filtre à huile Entretien DU GénérateurChangement dHuile à Moteur et de Filtre Vidange de lHuilePour Nettoyer le Générateur RemisageCommunications avec le Fabricant Dépannage Remarques Garantie Limitée