Briggs & Stratton Generator Important Safety Instructions, Do not dispose of battery in a fire

Page 3

Briggs & Stratton Power Products Home Standby Generator

Installation, Start-Up and Owner’s Manual

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

The safety alert symbol () is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard.The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating technique that the manufacturer does not specifically recommend, you must satisfy yourself that it is safe for you and others.You must also make sure that the procedure, work method or operating technique that you choose does not render the generator unsafe.

NOTE: Your generator is equipped with a spark arrester muffler.The spark arrester must be maintained in effective working order by the owner/operator. In the State of California, a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands.

WARNING

Only qualified electricians and gaseous fuel technicians should attempt installation of this generator, which must strictly comply with applicable codes, standards and regulations.

DANGER

Storage batteries give off explosive hydrogen gas during recharging.

Slightest spark will ignite hydrogen and cause explosion.

Battery electrolyte fluid contains acid and is extremely caustic.

Contact with battery contents will cause severe chemical burns.

A battery presents a risk of electrical shock and high short circuit current.

DO NOT dispose of battery in a fire.

DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.

DO NOT open or mutilate the battery.

Wear protective goggles, rubber apron, and rubber gloves.

Remove watches, rings, or other metal objects.

Use tools with insulated handles.

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Combustible debris, such as leaves, grass, brush, ect. can catch fire.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

The generator enclosure must be at least 5 feet from structures having combustible walls and/or other combustible materials.

Keep at least 3 feet of clearance on all sides of generator enclosure for adequate cooling, maintenance and servicing.

3

Image 3
Contents Installation Start-Up Table of Contents Important Safety Instructions Do not dispose of battery in a fireOperate generator only outdoors Amp fuse Before working on the equipment Introduction Installer ResponsibilitiesInstallation Assistance Save These Customer Instructions ResponsibilitiesBattery Know Your Home Standby GeneratorOil Fill AUTO/OFF/MANUAL Know Your Control PanelOwner Orientation Installation ProceduresShipment Contents Lifting the GeneratorHome Standby Generator Location Essential Circuits Essential Circuit SelectionDevice Running Watts Fuel Inlet Dimensions Removable Roof and Access DoorDisconnect Box Mounting Guidelines Gaseous Fuel System Load Fuel ConsumptionFrom Fuel To Home Standby10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ft Fuel Pipe SizingFuel Comparison Chart Physical Properties Propane Natural GasWithdrawal Rate 32F 20F 10F 30F 40F Before Initial START-UP Wire ConnectionsFuel Supply System Battery ConnectionCharging the Battery Servicing the BatteryFuel System Selection Automatic Operation SequenceInitial START-UP no Load Setting Exercise Timer Installation InspectionTo perform the Set Exercise procedure Servicing the System SpecificationsFault Detection System Automatic OperationEngine Fail To Start Number of LED Flashes Fault DescriptionReset Fault Detection System No LED Discharged BatteryChanging Oil Filter Generator MaintenanceChanging Engine Oil and Filter Changing OilTo Clean the Generator When Calling the FactoryStorage Problem Cause Correction TroubleshootingBriggs & Stratton Power Products Home Standby Generator Schematic Wiring Diagram Exploded View Main Unit Items Not Illustrated Parts List Main UnitOptional Accessories Not Illustrated DescriptionExploded View Enclosure Parts List Enclosure Exploded View Control Panel Parts List Control Panel SCREW, M5 .8 x 10 Taptite Exploded View and Parts List AlternatorHARNESS,Wire DC Charge ADAPTER, Mounting,AlternatorYear Consumer Use Years Years orTabla DE Contenido Manual de Instalación,Arranque y PropietarioSensor de Excitación de Tensión de la Compañía Peligro AdvertenciaLos generadores producen un voltaje muy poderoso PrecauciónResponsabilidades DEL Instalador Conserve Estas InstruccionesIntroducción Responsabilidades DEL ClienteTapón de Llenado y Varilla de Nivel de Aceite Permite Conozca SU Generador DE ReservaEtiqueta del Motor Tapón de Llenado y Varilla De Nivel de AceiteFusible de 15 Amperios Protege los circuitos de control de Conozca EL Panel DE ControlFusible de Disyuntor InterruptorProcedimientos DE Instalación Orientación Para EL PropietarioContenido de la Caja Elevación del GeneradorUbicación del Generador de Reserva Circuitos Fundamentales Selección de los Circuitos FundamentalesDispositivo Vatiaje de Dimensiones de la Entrada de Combustible Directrices de Montaje del Cuadro de DesconexiónTecho y Puerta de Acceso Desmontables El generador de reserva viene preparado de fábrica para Sistema DE Combustible Gaseoso AdvertenciaGas Natural Vapor de PL Consumo de CombustibleDimensiones de la Cañería de Combustible Gas Natural peso específico =Propano Líquido PL peso específico = Cuadro de Comparación de Combustibles Propiedades físicas Propano Gas naturalTasa de consumo 32F 20F 10F 30F 40F Antes DEL Arranque Inicial Conexiones DE CablesServicio la Batería Conexión de la BateríaSistema de Suministro de Combustible Cargar la BateríaSelección DEL Sistema DE Combustible Arranque Inicial SIN CargaSecuencia DE Operación Automática Ajuste DEL Temporizador DE Ejercicio Inspección Posterior a LA InstalaciónTemporizador de enfriamiento del motor Fallas EspecificacionesOperación Automática Sistema DE Detección DEBaja Presión de Aceite Cantidad de Destellos del LED Descripción de la FallaRestablecimiento del Sistema de Detección de Fallas No se Enciende el LED Batería DescargadaCambio del Aceite Mantenimiento DEL GeneradorCambio del Aceite del Motor y del Filtro Cambio del Filtro de AceiteAlmacenamiento Para Limpiar el GeneradorSi Llama a la Fábrica Reparacion DE Averias Garantía Limitada Entretien DE LA Génératrice Manuel dInstallation, Démarrage et UtilisateurTable DES Matières Fonctionnement AutomatiqueAvertissement NE touchez PAS les fils dénudés ou les boîtiers Introduction Responsabilités DE LinstallateurAide À Linstallation Conservez CES InstructionsFiltre à Air Et Jauge dHuile Filtre à lHuile FAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTEFAMILIARISEZ-VOUS Avec LE Tableau DE Commande 15 AmpèresDisjoncteur Interrupteur Conseils AU Propriétaire Procédures DinstallationSoulèvement de la Génératrice Emplacement du Génératrice d’état d’AttenteDirectives Générales Concernant lEmplacement Contenu de la BoîteCircuits Essentiels Sélection des Circuits EssentielsAppareil Watts Dimensions de lOrifice dAdmission du Combustible Directives dAssemblage du Boîtier de DébranchementToit Amovible et Porte dAccès Le génératrice d’état d’attente a été réglé en usine pour LE Système DE Combustible Gazeux AvertissementGas Naturel Vapeur PL Consommation de CombustibleGrosseur du Tuyau de Combustible Gaz Naturel densité = 0,65Gaz de Pétrole Liquéfié GPL densité = 1,50 Propriétés physiques Propane Gaz naturel Charte de Comparaison des CombustiblesAvant LE Démarrage Initial Raccords DE FilsEntretien de la Batterie Branchement de la BatterieSystème dAlimentation en Combustible Rechargez la BatterieSéquence DE Fonctionnement Automatique Capteur de Prise en Charge de la Tension de ServiceSélection DU Système DE Combustible Démarrage Initial SansMinuterie de Refroidissement du Moteur Vérification InstallationWarranty Registration Box Milwaukee,Wisconsin Réglage DE LA Minuterie DU Cycle DexerciceEntretien du Système CaractéristiquesFonctionnement Automatique Système DE Détection DES PannesFaible Pression dHuile Clignotements Du VoyantRéarmement du Système de Détection des Pannes Aucun DEL Batterie déchargéeVidange de lHuile Entretien DU GénérateurChangement dHuile à Moteur et de Filtre Changement du filtre à huileRemisage Pour Nettoyer le GénérateurCommunications avec le Fabricant Dépannage Remarques Garantie Limitée