Briggs & Stratton Shipment Contents, Lifting the Generator, Home Standby Generator Location

Page 9

Briggs & Stratton Power Products Home Standby Generator

Installation, Start-Up and Owner’s Manual

Shipment Contents

The Home Standby Generator is supplied with:

Home Standby Generator w/disconnect box

Pre-attached mounting pad

One 24” flexible hook-up hose

Installation, start-up and owner’s manual

Installation checklist

Remote diagnostic LED plate

Oil drain tray

Touch-up paint

One spare 15A fuse

LP conversion kit

Roof hardware bag

Lifting the Generator

CAUTION! The generator weighs more than 280 pounds. Proper tools, equipment and qualified personnel should be used in all phases of handling and moving generator.

CAUTION! DO NOT lift unit by roof as damage to generator will occur.

Lifting pockets are provided at each corner between the base of the generator and its mounting pad. Retouch any chipped paint with supplied touch-up paint.

Home Standby Generator Location

Before installing generator, consult with homeowner and convey the following guidelines which may affect the desired location.

Generator Clearances

The generator enclosure must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around the enclosure including the roof, for adequate cooling, maintenance and servicing.

Place generator in a well ventilated area which will allow for removal of deadly exhaust gas. DO NOT install generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 1). Prevailing winds and air currents should be taken into consideration when positioning generator.

General Location Guidelines

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

Install the unit outdoors ONLY.

Place the unit in a prepared location that is flat and has provisions for water drainage.

Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, etc. If prevailing winds will cause blowing or drifting, you may need to construct a windbreak to protect the unit.

Install the generator as close as possible to the Transfer Switch to reduce the length of wiring and conduit.

Install the generator as close as possible to the fuel supply to reduce length of pipes.

IMPORTANT: Laws or local codes may regulate the distance to the fuel supply.

Figure 1 — Home Standby Generator Clearances

Exhaust

Port

The Home Standby Generator is shipped already attached to its mounting pad. Unless mandated by local code, a concrete slab is not required.

If mandated by local code, construct a concrete slab at least 3 inches thick and 6 inches longer and wider than the unit. Attach unit to slab with 1/4” diameter (minimum) masonry anchor bolts long enough to retain the unit.

9

Image 9
Contents Installation Start-Up Table of Contents Important Safety Instructions Do not dispose of battery in a fireOperate generator only outdoors Amp fuse Before working on the equipment Installation Assistance Installer ResponsibilitiesSave These Customer Instructions Responsibilities IntroductionBattery Know Your Home Standby GeneratorOil Fill AUTO/OFF/MANUAL Know Your Control PanelOwner Orientation Installation ProceduresShipment Contents Lifting the GeneratorHome Standby Generator Location Essential Circuits Essential Circuit SelectionDevice Running Watts Fuel Inlet Dimensions Removable Roof and Access DoorDisconnect Box Mounting Guidelines Gaseous Fuel System From Fuel Fuel ConsumptionTo Home Standby Load10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ft Fuel Pipe SizingFuel Comparison Chart Physical Properties Propane Natural GasWithdrawal Rate 32F 20F 10F 30F 40F Before Initial START-UP Wire ConnectionsCharging the Battery Battery ConnectionServicing the Battery Fuel Supply SystemFuel System Selection Automatic Operation SequenceInitial START-UP no Load Setting Exercise Timer Installation InspectionTo perform the Set Exercise procedure Fault Detection System SpecificationsAutomatic Operation Servicing the SystemReset Fault Detection System Number of LED Flashes Fault DescriptionNo LED Discharged Battery Engine Fail To StartChanging Engine Oil and Filter Generator MaintenanceChanging Oil Changing Oil FilterTo Clean the Generator When Calling the FactoryStorage Problem Cause Correction TroubleshootingBriggs & Stratton Power Products Home Standby Generator Schematic Wiring Diagram Exploded View Main Unit Optional Accessories Not Illustrated Parts List Main UnitDescription Items Not IllustratedExploded View Enclosure Parts List Enclosure Exploded View Control Panel Parts List Control Panel HARNESS,Wire DC Charge Exploded View and Parts List AlternatorADAPTER, Mounting,Alternator SCREW, M5 .8 x 10 TaptiteYear Consumer Use Years Years orTabla DE Contenido Manual de Instalación,Arranque y PropietarioSensor de Excitación de Tensión de la Compañía Peligro AdvertenciaLos generadores producen un voltaje muy poderoso PrecauciónIntroducción Conserve Estas InstruccionesResponsabilidades DEL Cliente Responsabilidades DEL InstaladorEtiqueta del Motor Tapón de Llenado y Varilla Conozca SU Generador DE ReservaDe Nivel de Aceite Tapón de Llenado y Varilla de Nivel de Aceite PermiteFusible de Conozca EL Panel DE ControlDisyuntor Interruptor Fusible de 15 Amperios Protege los circuitos de control deProcedimientos DE Instalación Orientación Para EL PropietarioContenido de la Caja Elevación del GeneradorUbicación del Generador de Reserva Circuitos Fundamentales Selección de los Circuitos FundamentalesDispositivo Vatiaje de Dimensiones de la Entrada de Combustible Directrices de Montaje del Cuadro de DesconexiónTecho y Puerta de Acceso Desmontables El generador de reserva viene preparado de fábrica para Sistema DE Combustible Gaseoso AdvertenciaGas Natural Vapor de PL Consumo de CombustibleDimensiones de la Cañería de Combustible Gas Natural peso específico =Propano Líquido PL peso específico = Cuadro de Comparación de Combustibles Propiedades físicas Propano Gas naturalTasa de consumo 32F 20F 10F 30F 40F Antes DEL Arranque Inicial Conexiones DE CablesSistema de Suministro de Combustible Conexión de la BateríaCargar la Batería Servicio la BateríaSelección DEL Sistema DE Combustible Arranque Inicial SIN CargaSecuencia DE Operación Automática Ajuste DEL Temporizador DE Ejercicio Inspección Posterior a LA InstalaciónTemporizador de enfriamiento del motor Operación Automática EspecificacionesSistema DE Detección DE FallasRestablecimiento del Sistema de Detección de Fallas Cantidad de Destellos del LED Descripción de la FallaNo se Enciende el LED Batería Descargada Baja Presión de AceiteCambio del Aceite del Motor y del Filtro Mantenimiento DEL GeneradorCambio del Filtro de Aceite Cambio del AceiteAlmacenamiento Para Limpiar el GeneradorSi Llama a la Fábrica Reparacion DE Averias Garantía Limitada Table DES Matières Manuel dInstallation, Démarrage et UtilisateurFonctionnement Automatique Entretien DE LA GénératriceAvertissement NE touchez PAS les fils dénudés ou les boîtiers Aide À Linstallation Responsabilités DE LinstallateurConservez CES Instructions IntroductionFiltre à Air Et Jauge dHuile Filtre à lHuile FAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTEFAMILIARISEZ-VOUS Avec LE Tableau DE Commande 15 AmpèresDisjoncteur Interrupteur Conseils AU Propriétaire Procédures DinstallationDirectives Générales Concernant lEmplacement Emplacement du Génératrice d’état d’AttenteContenu de la Boîte Soulèvement de la GénératriceCircuits Essentiels Sélection des Circuits EssentielsAppareil Watts Dimensions de lOrifice dAdmission du Combustible Directives dAssemblage du Boîtier de DébranchementToit Amovible et Porte dAccès Le génératrice d’état d’attente a été réglé en usine pour LE Système DE Combustible Gazeux AvertissementGas Naturel Vapeur PL Consommation de CombustibleGrosseur du Tuyau de Combustible Gaz Naturel densité = 0,65Gaz de Pétrole Liquéfié GPL densité = 1,50 Propriétés physiques Propane Gaz naturel Charte de Comparaison des CombustiblesAvant LE Démarrage Initial Raccords DE FilsSystème dAlimentation en Combustible Branchement de la BatterieRechargez la Batterie Entretien de la BatterieSélection DU Système DE Combustible Capteur de Prise en Charge de la Tension de ServiceDémarrage Initial Sans Séquence DE Fonctionnement AutomatiqueWarranty Registration Box Milwaukee,Wisconsin Vérification InstallationRéglage DE LA Minuterie DU Cycle Dexercice Minuterie de Refroidissement du MoteurFonctionnement Automatique CaractéristiquesSystème DE Détection DES Pannes Entretien du SystèmeRéarmement du Système de Détection des Pannes Clignotements Du VoyantAucun DEL Batterie déchargée Faible Pression dHuileChangement dHuile à Moteur et de Filtre Entretien DU GénérateurChangement du filtre à huile Vidange de lHuileRemisage Pour Nettoyer le GénérateurCommunications avec le Fabricant Dépannage Remarques Garantie Limitée