Briggs & Stratton Generator Battery Connection, Fuel Supply System, Charging the Battery

Page 17

Briggs & Stratton Power Products Home Standby Generator

Installation, Start-Up and Owner’s Manual

Battery Connection

The Home Standby Generator is supplied with a 12 Volt DC,AGM type, 33 Amp-Hour, valve regulated battery. It is a sealed, lead-acid rechargeable battery. It is installed in the unit and the battery cables are connected at the factory.The unit’s 15 Amp fuse, which isolates the battery and prevents the unit from starting, has been removed for shipping.The battery will lose some charge charge prior to installation of the generator. If battery voltage is below 12 Volts, charge the battery.

IMPORTANT: If battery voltage is below 5 Volts, it may not take a charge and you will need a new battery.

Charging the Battery

If it is necessary to charge the battery, proceed as follows:

1.Set the generator's “AUTO/OFF/MANUAL” switch to OFF.

2.Remove the 15 Amp fuse from the control panel.

3.Disconnect the negative battery cable to the negative battery terminal (indicated by NEGATIVE, NEG, or (-).

CAUTION

Failure to disconnect negative battery cable will result in equipment failure.

DO NOT attempt to jump start the battery.

Damage to equipment resulting from failure to follow this instruction will void warranty.

4.Charge battery with battery charger at 2 Amps until battery holds 12 Volts.

DANGER

Storage batteries give off explosive hydrogen gas during recharging.

Slightest spark will ignite hydrogen and cause explosion.

Battery electrolyte fluid contains acid and is extremely caustic.

Contact with battery contents will cause severe chemical burns.

A battery presents a risk of electrical shock and high short circuit current.

DO NOT dispose of battery in a fire.

DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.

DO NOT open or mutilate the battery.

Wear protective goggles, rubber apron, and rubber gloves.

Remove watches, rings, or other metal objects.

Use tools with insulated handles.

NOTE: With the battery installed and utility power available to the Automatic Transfer Switch, the battery receives a trickle charge whenever the engine is not running.This process may take up to 72 hours to fully charge a battery from 5 Volts.The trickle charge cannot be used to recharge a battery that is completely discharged.

5.Connect the negative battery cable to the negative battery terminal (indicated by NEGATIVE, NEG, or (-).

6.Ensure hardware on both positive and negative battery terminals is secure.

7.Reinstall the 15 Amp fuse in the control panel.

CAUTION

Installing the 15A fuse could cause the engine to start.

DO NOT install the 15 Amp fuse until all plumbing and wiring has been completed and inspected.

8.Set the generator's “AUTO/OFF/MANUAL” switch to AUTO.

Servicing the Battery

If it is necessary to service the battery, proceed as follows:

1.Set the generator's “AUTO/OFF/MANUAL” switch to OFF.

2.Remove the 15 Amp fuse from the control panel.

3.Service or replace battery as required.

4.Connect the red battery cable to the battery positive terminal (indicated by POSITIVE, POS, or (+)).

5.Connect the negative battery cable to the negative battery terminal (indicated by NEGATIVE, NEG, or (-).

6.Ensure hardware on both positive and negative battery terminals is secure.

7.Reinstall the 15 Amp fuse in the control panel.

8.Set the generator's “AUTO/OFF/MANUAL” switch to AUTO.

Fuel Supply System

Ensure that all fuel pipe connections are tight, secure and without leaks.

Ensure that all gas line shutoff valves are OPEN and that adequate fuel pressure is available whenever automatic operation is desired.

17

Image 17
Contents Installation Start-Up Table of Contents Operate generator only outdoors Important Safety InstructionsDo not dispose of battery in a fire Amp fuse Before working on the equipment Installation Assistance Installer ResponsibilitiesSave These Customer Instructions Responsibilities IntroductionOil Fill BatteryKnow Your Home Standby Generator AUTO/OFF/MANUAL Know Your Control PanelOwner Orientation Installation ProceduresHome Standby Generator Location Shipment ContentsLifting the Generator Device Running Watts Essential CircuitsEssential Circuit Selection Disconnect Box Mounting Guidelines Fuel Inlet DimensionsRemovable Roof and Access Door Gaseous Fuel System From Fuel Fuel ConsumptionTo Home Standby Load10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ft Fuel Pipe SizingWithdrawal Rate 32F 20F 10F 30F 40F Fuel Comparison ChartPhysical Properties Propane Natural Gas Before Initial START-UP Wire ConnectionsCharging the Battery Battery ConnectionServicing the Battery Fuel Supply SystemInitial START-UP no Load Fuel System SelectionAutomatic Operation Sequence To perform the Set Exercise procedure Setting Exercise TimerInstallation Inspection Fault Detection System SpecificationsAutomatic Operation Servicing the SystemReset Fault Detection System Number of LED Flashes Fault DescriptionNo LED Discharged Battery Engine Fail To StartChanging Engine Oil and Filter Generator MaintenanceChanging Oil Changing Oil FilterStorage To Clean the GeneratorWhen Calling the Factory Problem Cause Correction TroubleshootingBriggs & Stratton Power Products Home Standby Generator Schematic Wiring Diagram Exploded View Main Unit Optional Accessories Not Illustrated Parts List Main UnitDescription Items Not IllustratedExploded View Enclosure Parts List Enclosure Exploded View Control Panel Parts List Control Panel HARNESS,Wire DC Charge Exploded View and Parts List AlternatorADAPTER, Mounting,Alternator SCREW, M5 .8 x 10 TaptiteYear Consumer Use Years Years orSensor de Excitación de Tensión de la Compañía Tabla DE ContenidoManual de Instalación,Arranque y Propietario Peligro AdvertenciaLos generadores producen un voltaje muy poderoso PrecauciónIntroducción Conserve Estas InstruccionesResponsabilidades DEL Cliente Responsabilidades DEL InstaladorEtiqueta del Motor Tapón de Llenado y Varilla Conozca SU Generador DE ReservaDe Nivel de Aceite Tapón de Llenado y Varilla de Nivel de Aceite PermiteFusible de Conozca EL Panel DE ControlDisyuntor Interruptor Fusible de 15 Amperios Protege los circuitos de control deProcedimientos DE Instalación Orientación Para EL PropietarioUbicación del Generador de Reserva Contenido de la CajaElevación del Generador Dispositivo Vatiaje de Circuitos FundamentalesSelección de los Circuitos Fundamentales Techo y Puerta de Acceso Desmontables Dimensiones de la Entrada de CombustibleDirectrices de Montaje del Cuadro de Desconexión El generador de reserva viene preparado de fábrica para Sistema DE Combustible Gaseoso AdvertenciaGas Natural Vapor de PL Consumo de CombustiblePropano Líquido PL peso específico = Dimensiones de la Cañería de CombustibleGas Natural peso específico = Tasa de consumo 32F 20F 10F 30F 40F Cuadro de Comparación de CombustiblesPropiedades físicas Propano Gas natural Antes DEL Arranque Inicial Conexiones DE CablesSistema de Suministro de Combustible Conexión de la BateríaCargar la Batería Servicio la BateríaSecuencia DE Operación Automática Selección DEL Sistema DE CombustibleArranque Inicial SIN Carga Temporizador de enfriamiento del motor Ajuste DEL Temporizador DE EjercicioInspección Posterior a LA Instalación Operación Automática EspecificacionesSistema DE Detección DE FallasRestablecimiento del Sistema de Detección de Fallas Cantidad de Destellos del LED Descripción de la FallaNo se Enciende el LED Batería Descargada Baja Presión de AceiteCambio del Aceite del Motor y del Filtro Mantenimiento DEL GeneradorCambio del Filtro de Aceite Cambio del AceiteSi Llama a la Fábrica AlmacenamientoPara Limpiar el Generador Reparacion DE Averias Garantía Limitada Table DES Matières Manuel dInstallation, Démarrage et UtilisateurFonctionnement Automatique Entretien DE LA GénératriceAvertissement NE touchez PAS les fils dénudés ou les boîtiers Aide À Linstallation Responsabilités DE LinstallateurConservez CES Instructions IntroductionFiltre à Air Et Jauge dHuile Filtre à lHuile FAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTEDisjoncteur Interrupteur FAMILIARISEZ-VOUS Avec LE Tableau DE Commande15 Ampères Conseils AU Propriétaire Procédures DinstallationDirectives Générales Concernant lEmplacement Emplacement du Génératrice d’état d’AttenteContenu de la Boîte Soulèvement de la GénératriceAppareil Watts Circuits EssentielsSélection des Circuits Essentiels Toit Amovible et Porte dAccès Dimensions de lOrifice dAdmission du CombustibleDirectives dAssemblage du Boîtier de Débranchement Le génératrice d’état d’attente a été réglé en usine pour LE Système DE Combustible Gazeux AvertissementGas Naturel Vapeur PL Consommation de CombustibleGaz de Pétrole Liquéfié GPL densité = 1,50 Grosseur du Tuyau de CombustibleGaz Naturel densité = 0,65 Propriétés physiques Propane Gaz naturel Charte de Comparaison des CombustiblesAvant LE Démarrage Initial Raccords DE FilsSystème dAlimentation en Combustible Branchement de la BatterieRechargez la Batterie Entretien de la BatterieSélection DU Système DE Combustible Capteur de Prise en Charge de la Tension de ServiceDémarrage Initial Sans Séquence DE Fonctionnement AutomatiqueWarranty Registration Box Milwaukee,Wisconsin Vérification InstallationRéglage DE LA Minuterie DU Cycle Dexercice Minuterie de Refroidissement du MoteurFonctionnement Automatique CaractéristiquesSystème DE Détection DES Pannes Entretien du SystèmeRéarmement du Système de Détection des Pannes Clignotements Du VoyantAucun DEL Batterie déchargée Faible Pression dHuileChangement dHuile à Moteur et de Filtre Entretien DU GénérateurChangement du filtre à huile Vidange de lHuileCommunications avec le Fabricant RemisagePour Nettoyer le Générateur Dépannage Remarques Garantie Limitée