Aqua Products manual RP2100+ Heat Exchanger Reversal Procedure

Page 18

RP2100+ Heat Exchanger Reversal Procedure

(Capron Resin Header Models)

1.Remove right and left side access panels (Figure 1).

2.Disconnect wires at high limit, AGS (automatic gas shutoff), and pressure switch on the inlet/outlet header (Figure 2).

3.Electronic Ignition Heaters: Remove the thermostat temperature sensor by loosening the compression- fitting nut (Figure 3). Reroute the sensor to the left side of the heater.

4.Millivolt Heaters: Remove the temperature sensor bulb and retainer clip from the sensor well (Figure 4). Reroute the sensor bulb to the left side of the heater.

5.Remove (12) bolts holding the inlet/outlet and return headers to the tube sheets. Clean off tube sheet area where the gasket seats. Also clean off the header and its gasket. Apply a non-petroleum based lubricant to the gasket such as Aqua Lube. Reattach the headers to the opposite sides, making sure they are installed in an upright position (Figure 5). Do not over tighten. Torque should not exceed 7 ft/lbs.

6.Reconnect high limit, AGS, and pressure switch wires.

7.Electronic Ignition Heaters: Insert the temperature sensor in the compression fitting and tighten 1/2 turn past hand tight.

8.Millivolt Heaters: Insert sensor bulb and retainer clip into sensor well.

9.Allow for water flow through the heater and check for leaks.

10.Reattach access panels to the opposite sides.

For ASME Models call your factory representative.

ACCESS PANEL

Fig. #1

PRESS SWITCH

AGS

HI-LIMIT

Fig. #2

18

Image 18
Contents Installation Operating Instructions What to do if YOU Smell GASTo Whom IT MAY Concern Contents Burners START-UP ProceduresBefore START-UP WaterMillivolt System Lighting InstructionsTo Turn OFF GAS to Appliance Electronic Ignitions Systems What to do if YOU Smell GASOperating Instructions After START-UP Maintenance and Care ProceduresWater Pressure Switch Visual InspectionAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS Basic Tips if Heater will not FirePool & SPA Water Chemistry ColdweatheroperationWinterizing the Pool & SPA Heater General SpecificationsReceiving Equipment Standard Unit Asme UnitInstallation Instructions Heater with Outdoor Stackless TOP Feet horizontallyVent TERMINAL/INDOOR Stack Installation Indoor HeaterSpecifications and Dimensions Combustion AIR Indoor Units OnlyVent Piping GAS Supply ConnectionsPipe Sizing for GAS Connections GAS Pressure Adjustment LocationsGAS Pressure Regulator Plumbing for Water ConnectionsConnections Auxiliary Bypass Valve AdjustmentFlow Rates Model Pipe Size MIN.GPM MAX.GPM INLET/OUTLETHEADERPressure Relief Valve Installation Fig. #2004RP2100+ Heat Exchanger Reversal Procedure Jaco Fitting Electronic Intermittent Ignition Device System IID ElectricalwiringMillivolt System AtmosphericWiring Diagram KEY Wiring Diagram Millivolt Units With Mechanical ThermostatWiring Diagram IID Units atmospheric Wiring Diagram IID Units Low NOx CONTROLS/ADJUSTMENTS/REPLACEMENTS Servicing InstructionsGeneral Location of Controls Display Faults Electronic ControlsDisplay Status RP2100 Remote Control Installation Three Wire TWO FunctionTWO Wire ONE Function ON/OFF only Pressure Switch Flame ROLL-OUT Safety SwitchHigh Limits Honeywell Pilot Robertshaw Pilot Unitherm Governor U.G. Replacement Tube Cleaning ProcedureDesooting Procedure Combustion Chamber RemovalFlame ROLL-OUT Safety Switch START-UP Procedures S8610BBurneradjustment OperationAddenda LOW NOX Heaters Trouble Shooting Guide MechanicalforqualifiedservicepersonnelonlyElectrical Standing Pilot Millivolt Raypak Pool or SPA Heater Electrical Check with MV GAS ValveTroubleshooting Honeywell S8600 Electrical Electronic Ignition IIDPage Replacement Parts List RAYPAK,INCPage Pilot Assemblies Honeywell IID Atmospheric unitsPage Page Page Limitedwarranty Raypakresidentialswimmingpoolandspaheaters