Aqua Products RP2100, P-R185A, P-R405A, C-R185A, P-R405A Millivolt System, Lighting Instructions

Page 5

CAUTION: Propane gas is heavier than air and will settle on the ground. Since propane can accumulate in confined areas, extra care should be exercised when lighting propane heaters.

LIGHTING INSTRUCTIONS AND SHUT-OFF PROCEDURES

MANUALLY LIGHTED PILOTS

MILLIVOLT SYSTEM

A.This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS: *Do not try to light any appliance.

*Do not touch any electric switch; do not use any phone in your building.

*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

*If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explo- sion.

D.Do not use this appliance if any part has been underwater. Immediately call a qualified serv- ice technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat on the lowest setting.

3.Turn On/Off switch to the "Off" position.

4.Remove heater door panel.

5.Push in gas control knob slightly and turn

clockwise to "Off".

NOTE: Knob cannot be turned from "Pilot" to Off" unless knob is pushed in slightly. Do not force.

6.Wait 5 minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Locate pilot mounted on the right side panel of the burner drawer. For burner drawer location, see location of control section, page 20.

GAS CONTROL KNOB SHOWN IN OFF POSITION

HONEYWELL

GAS VALVE

MILLIVOLT

ROBERTSHAW

Fig. # 8081.0GAS VALVE

MILLIVOLT

HONEYWELL PILOT

ROBERTSHAW PILOT

Fig. # 8083.0

Fig. # 8084.1

8.Turn knob on gas control counter-clockwise

to "Pilot"

9.Place flame to end of pilot tube. Push in control knob all the way and hold to light pilot. Continue to hold control knob in for about one minute after the pilot is lighted, release knob and it will pop back up. Pilot should remain lighted. If it goes out, repeat steps 5 through 9. *If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

10.Stand to the side of the heater and turn the gas

control knob counter clockwise to "On".

11.Replace heater door panel.

12.Turn On/Off switch to the "On" position.

13.Set thermostat to the desired setting.

Fig. # 8079.0

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting.

2.Turn On/Off switch to the "Off" position.

3.Remove heater door panel.

4.Push the gas control knob slightly and turn

clockwise to "Off". Do not force.

5.Replace heater door panel.

5

Image 5
Contents What to do if YOU Smell GAS Installation Operating InstructionsTo Whom IT MAY Concern Contents Before START-UP START-UP ProceduresBurners WaterTo Turn OFF GAS to Appliance Millivolt SystemLighting Instructions Operating Instructions Electronic Ignitions SystemsWhat to do if YOU Smell GAS Water Pressure Switch Maintenance and Care ProceduresAfter START-UP Visual InspectionPool & SPA Water Chemistry Basic Tips if Heater will not FireAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS ColdweatheroperationReceiving Equipment General SpecificationsWinterizing the Pool & SPA Heater Standard Unit Asme UnitInstallation Instructions Feet horizontally Heater with Outdoor Stackless TOPIndoor Heater Vent TERMINAL/INDOOR Stack InstallationCombustion AIR Indoor Units Only Specifications and DimensionsGAS Supply Connections Vent PipingGAS Pressure Regulator GAS Pressure Adjustment LocationsPipe Sizing for GAS Connections Plumbing for Water ConnectionsFlow Rates Model Pipe Size MIN.GPM MAX.GPM Auxiliary Bypass Valve AdjustmentConnections INLET/OUTLETHEADERFig. #2004 Pressure Relief Valve InstallationRP2100+ Heat Exchanger Reversal Procedure Jaco Fitting Millivolt System ElectricalwiringElectronic Intermittent Ignition Device System IID AtmosphericWiring Diagram Millivolt Units With Mechanical Thermostat Wiring Diagram KEYWiring Diagram IID Units atmospheric Wiring Diagram IID Units Low NOx General Location of Controls CONTROLS/ADJUSTMENTS/REPLACEMENTSServicing Instructions Display Status Display FaultsElectronic Controls TWO Wire ONE Function ON/OFF only RP2100 Remote Control InstallationThree Wire TWO Function High Limits Pressure SwitchFlame ROLL-OUT Safety Switch Honeywell Pilot Robertshaw Pilot Desooting Procedure Tube Cleaning ProcedureUnitherm Governor U.G. Replacement Combustion Chamber RemovalBurneradjustment START-UP Procedures S8610BFlame ROLL-OUT Safety Switch OperationAddenda LOW NOX Heaters Mechanicalforqualifiedservicepersonnelonly Trouble Shooting GuideRaypak Pool or SPA Heater Electrical Check with MV GAS Valve Electrical Standing Pilot MillivoltElectrical Electronic Ignition IID Troubleshooting Honeywell S8600Page RAYPAK,INC Replacement Parts ListPage Honeywell IID Atmospheric units Pilot AssembliesPage Page Page Limitedwarranty Raypakresidentialswimmingpoolandspaheaters