Able Planet OL-1747-02 manual To specify switch settings for Cisco CallManager

Page 33

Chapter 2 Dual Phone System Integration

Changing Cisco Unity Administrator Settings

Step 3

Adjust other settings as appropriate. For more information about the other settings

 

on the Switch page, see the online Help in the Cisco Unity Administrator.

Step 4

Click the Save icon, then click OK in the Warning dialog box.

 

 

 

 

To specify switch settings for Cisco CallManager

 

 

 

Step 1

Go to System > Switch > IP Switch.

Step 2

In the Set Active Switch Type section, enter values as shown in the following

 

table:

 

 

Table 2-1 Switch Settings

 

 

 

 

 

Switch Parameter

Required Setting

 

 

 

 

Manufacturer

Cisco

 

 

 

 

Model

CallManager

 

 

 

 

Switch PBX software version

3.01 or later

 

 

 

 

Integration

TAPI

 

 

 

Step 3

Click Set As Active, then click OK in the Warning dialog box.

Step 4

In the Access Code field, enter the trunk access code that Cisco Unity must dial

 

to transfer calls to the traditional phone system from Cisco CallManager.

 

The access code is the same number that subscribers on Cisco CallManager dial

 

to reach someone on the traditional phone system.

Step 5

Click the Save icon, then click OK in the Warning dialog box.

 

 

 

 

To modify voice port settings

 

 

 

 

Step 1

Go to System > Ports.

 

 

 

Siemens 9751 9006i DTMF Integration Guide

 

 

 

 

 

 

OL-1747-02

 

 

2-5

 

 

 

Image 33
Contents Siemens 9751 9006i Dtmf Integration Guide Siemens 9751 9006i Dtmf Integration Guide Preface Exiting the Cisco Unity Software A-1 Audience PurposeOrganization ConventionsConvention Description Document Location Cisco Unity DocumentationViii World Wide Web Obtaining DocumentationDocumentation CD-ROM Ordering DocumentationObtaining Technical Assistance Documentation FeedbackCisco.com Technical Assistance Center Contacting TAC by Using the Cisco TAC WebsiteContacting TAC by Telephone Integration Steps Integration OverviewPhone System RequirementsCisco Unity Server Integration DescriptionProgramming the Phone System Integration FeaturesTo program the phone system for analog ports Parameter Required SettingNytpe NAT Actcde Devfunc Anate Msgwlmp Specl Type VCE FPN ParameterConfiguring Cisco Unity for the Integration To confirm that the integration is enabledTransfer Type Usage To enter port settings Switch Parameter Required SettingTo set up the test configuration Testing the IntegrationTo test an external call with release transfer To test an internal call with release transfer To test supervised transfer To set up supervised transfer on Cisco UnityTo return Example Subscriber to the default settings Dual Phone System Integration Overview Integration Steps When No Phone Systems Are InstalledSiemens 9751 9006i Dtmf Integration Guide Changing Cisco Unity Administrator Settings To specify switch settings for the traditional phone system To modify voice port settings To specify switch settings for Cisco CallManagerSiemens 9751 9006i Dtmf Integration Guide OL-1747-02 Changing the Number of Installed Ports To remove the existing AV-Cisco TSP To reinstall the AV-Cisco service providerOL-1747-02 To exit the Cisco Unity software from another computer Exiting the Cisco Unity SoftwareTo shut down or restart the Cisco Unity server Starting the Cisco Unity SoftwareClick Start Cisco Unity To start the Cisco Unity software from another computer Setting Up Cisco Unity to Remap Extension Numbers Remapping Extension Numbers Remapping FeatureTo remap extension numbers Wildcard Result Syntax and ExamplesRule Original Number New Number Phone System Integration Click OK To set the Port assignments in the RegistryOL-1747-02 OL-1747-02