Intel E8500 manual Reliability Guidelines

Page 29

NB Reference Thermal Solution #1

6.6Reliability Guidelines

Each motherboard, heatsink and attach combination may vary the mechanical loading of the component. Based on the end user environment, the user should define the appropriate reliability test criteria and carefully evaluate the completed assembly prior to use in high volume. Some general recommendations are shown in Table 6-2.

Table 6-2. Reliability Guidelines

Test (1)

Requirement

Pass/Fail Criteria (2)

Mechanical

50 g, board level, 11 msec, 3 shocks/axis

Visual Check and Electrical Functional

Shock

 

Test

 

 

 

Random

7.3 g, board level, 45 min/axis, 50 Hz to

Visual Check and Electrical Functional

Vibration

2000 Hz

Test

 

 

 

Temperature Life

85°C, 2000 hours total, checkpoints at 168,

Visual Check

 

500, 1000, and 2000 hours

 

 

 

 

Thermal Cycling

–5°C to +70°C, 500 cycles

Visual Check

 

 

 

Humidity

85% relative humidity, 55°C, 1000 hours

Visual Check

 

 

 

NOTES:

1.It is recommended that the above tests be performed on a sample size of at least twelve assemblies from three lots of material.

2.Additional pass/fail criteria may be added at the discretion of the user.

§

Intel® E8500 Chipset North Bridge (NB) and eXternal Memory

29

Bridge (XMB) Thermal/Mechanical Design Guide

 

Image 29
Contents Thermal/Mechanical Design Guide Intel E8500 Chipset North Bridge NB and eXternal Memory Contents Figures Tables Revision History Design Flow IntroductionBGA Definition of TermsXMB Reference DocumentsIntroduction TNB Packaging TechnologyNB Package Dimensions Bottom View XMB Package Dimensions Top View Package Mechanical Requirements XMB Package Dimensions Bottom ViewDie Case Temperature Specifications Thermal SpecificationsThermal Design Power TDP Intel E8500 Chipset XMB Thermal Specifications Thermal Simulation Thermal Simulation Thermal Metrology Die Case Temperature MeasurementsThermal Solution Decision Flowchart Power Simulation Software Thermal Metrology Heatsink Performance NB Reference Thermal Solution #1Operating Environment Mechanical Design Envelope First NB Reference Heatsink Volumetric Envelope Board-Level Components Keepout DimensionsTNBLocation First NB Heatsink Thermal Solution AssemblyExtruded Heatsink Profiles Heatsink Retaining Fastener Reliability Guidelines Reliability GuidelinesNB Reference Thermal Solution #1 NB Reference Thermal Solution #2 NB Reference Thermal Solution #2 Second NB Reference Heatsink Volumetric Envelope Second NB Heatsink Thermal Solution AssemblySecond NB Heatsink Assembly Please refer to .6 for detail NB Reference Thermal Solution #2 XMB Reference Thermal Solution XMB Reference Heatsink Volumetric Envelope XMB Heatsink Thermal Solution AssemblyXMB Location Extruded Heatsink Profiles XMB Heatsink Extrusion Profile XMB Reference Thermal Solution Table A-1 NB Heatsink Thermal Solution #1 Thermal Solution Component SuppliersTable A-2 NB Heatsink Thermal Solution #2 Table A-3 XMB Heatsink Thermal Solution Thermal Solution Component Suppliers Table B-1. Mechanical Drawing List Mechanical DrawingsFigure B-1. NB Heatsink #1 Assembly Drawing Figure B-2. NB Heatsink #1 Drawing Figure B-3. NB Heatsink #2 Assembly Drawing Figure B-4. NB Heatsink #2 Drawing Figure B-5. XMB Heatsink Assembly Drawing Figure B-6. XMB Heatsink Drawing Intel E8500 Chipset North Bridge NB and eXternal Memory