3 Using the TWAIN Datasource

Installation

Overview

Terminology and features

The TWAIN Datasource is included with the scanner. You can install the Datasource from the CD.

1.Insert the CD into the drive.

2.Double-click the setup.exe file.

3.Follow the instructions on each screen as prompted.

After installation is complete, install your application software on the host PC.

A sample TWAIN Datasource application, called the Scan Validation Tool, is also provided as part of this installation. This application can be used to validate scanner functionality. The screen shots in this chapter (from the Scan Validation Tool) document the TWAIN Datasource graphical user interface which can be one option when creating your own Setting Shortcut.

All Kodak Scanners have the capability of providing a wide variety of electronic images. This can be accomplished by using the provided TWAIN Datasource in concert with your scanning application. The TWAIN Datasource is the part of the capture system which links the scanner to your scanning application.

When using the TWAIN Datasource, the main Kodak Scanner window will display a list of Setting Shortcuts. Each Setting Shortcut is a group of specific image and device settings. The supplied Setting Shortcuts represent some common electronic image outputs. If none of the Setting Shortcuts meet your scanning needs, you can create a customized Setting Shortcut.

This chapter provides descriptions of the scanner features using options on the TWAIN Datasource tabs. If you are using the TWAIN Datasource, follow the procedures in this chapter to set up your scanner. If you are using the ISIS driver, see Chapter 4, Using the ISIS Driver.

If you have used previous scanners from Kodak, you may be familiar with many of the image processing features already. With the new graphical user interface in the TWAIN Datasource, some of the names of those features have changed. Refer to Appendix A, TWAIN Image Processing Terminology for a cross reference of previous names with new names.

A-61580 November 2007

3-1

Image 29
Contents Page About this manual IntroductionImage outputs FG.jpg Best Practices Scanner setup Enable scanning Error handlingDisable scanning Initiate pollingPage Controlling image transfer order Dual stream duplex Dual stream simplexPage Jam and fault recovery Bar code recognition Image file storage locationsImage addressing Image address formatNext image address Starting image addressIndexing schemes Single level indexingTwo level indexing Two level offset indexing Three level indexing Three level offset indexing Generated Automatically Level rules Electronic color dropoutControlling print strings Print string formattingContrast% = Threshold = Color Filter = Resolution = 200 dpiRed dropout Red Dropout  Near Complete DropoutGreen Dropout  Near Complete Dropout Green Dropout  Complete DropoutBlue Dropout  Complete Dropout Blue Dropout  Near Complete DropoutImage header information Page Original Black and white image Relative Cropping Zone processingPatch reading Programmable keysPatch code types Type 3 Patch CodeAdditional Patch Codes Transfer Patch CodeToggle Patch Batching Installation Overview Terminology and features Using the Twain DatasourceValidation tool Accessing the ScanSelect StartProgramsKodakDocument ImagingScan Validation ToolPage Main Kodak Scanner window Page Information icons Image Settings window Preview area Toolbar buttonsInformation icons Cases you will not have to change options on other tabs TabPage November None Landscape Degrees Scan as selection of Black and White Image SettingsAdjustments tab Image None Filters Noise NoneEnhancements tab Advanced Image Setup Input document is select Two Sided, One Sided Front, or One Advanced tabPage Done returns you to the Image Settings window November Sensitivity Content Settings tabPage Select Grayscale Select Sides Both Black and White 1-bit Select Sides Both Color 24-bitMake sure Black and White 1-bit is selected Creating multiple images for each side of a documentSelect Sides Both Color 24-bit Select Sides Back Creating different settings for each side of a documentSelect Sides Front Device Settings window Document Feeder Device General tabPaper source Page Device Printer tab Page Yyyyddd Julian Date FormatFeed Direction 180 270 Ultrasonic detection Page Template Do Not Display e.g., A.3.2.1 Display as Spaces e.g., a Reached. Options are none, Level 1, Level 2, and Level When Count ReachedDevice Batch tab November As Level Device Patch tabFeature Device OCP tab Creating a new Setting Shortcut Page Page Main Isis Driver window Using the Isis DriverMain tab Image ModePage Page Image Orientation Layout tabGeneral options When Fixed to Transport or Relative to Document is selectedSuperior Color optionsScanner tab Power Saver TimeoutMulti-feed Detection OptionsPage Operations Page Color Content Learn Blank Image Detection Dropout tabColor Dropout Mode Imprinter tabUnits select Inches, Centimeters or Pixels Defining your print stringHyphen -, Period . , Blank or none. For example 08/24/2007 Image Address tab Level 2 Offset Address%2L Batch Control Batch/Patch tabGo to Level 3 or no action Transport End of Job, Continue and Begin New Batch or noLevel 2 or Patch T / Transfer Patch Level Patch DetectionPatch 4/Toggle Patch PatchOCP tab Operator Log tab About tab Page Area Appendix a Twain Image Processing Terminology Feature Cropping