Agilent Technologies G6600-90006 manual SCD Right Side

Page 30

16

18

17

 

 

 

TP2

 

 

 

 

TP4

 

TP3

 

 

12

 

 

 

 

 

 

TP5

 

TP12

 

 

 

TP1

 

TP8

HV/100

 

 

GND

TP13

 

TP11

 

 

 

 

TP14

TP9

 

 

 

 

TP6 TP7

TP16 TP15

TP10

 

 

 

ELECTRONICS

 

 

RV1

 

 

 

 

 

 

HV

 

 

 

 

 

 

 

LOAD

PUMP

NEUT

 

 

 

 

P4

P5

OZONE

 

 

 

 

OUT

WHT

 

 

 

 

 

 

PUMP

15

 

 

 

 

NEUT

 

 

P6

 

P7

 

 

 

 

 

 

WHT

 

 

 

 

P2

AC

 

 

 

 

 

 

 

WHT

11

IN OFST

 

 

OUT OFST

RV1

 

 

 

RV2

 

 

 

 

 

 

 

I

 

 

 

AMP 1

TP8

TP10

TP12

TP2

TP13

 

OUT

TP5

TP4TP6 TP7

13

 

 

 

TP3

 

 

 

ALCO

 

TO

 

 

 

FRONT

TP1

 

 

PANEL

TP9

 

 

 

USA

 

 

 

 

 

TP11

 

SIEVERS RESEARCH

14

11.

Amplifier Cable

15.

Fuses

12.

HV Cable

16.

Pressure Regulator

13.

PMT Amplifier

17.

Transfer line

14.

EMI Filter

18.

Front panel display

Figure 4 355 SCD Right Side

30

Operation and Maintenance Manual

Image 30
Contents Operation and Maintenance Manual Acknowledgements WarrantySafety Notices Manual Part NumberEnglish WA R N I N GIs not in use Español Français Deutsch Italiano Dutch Veiligheidsvoorzieningen niet meerFollowing symbols are used on the equipment Contents Installation OverviewFront Panel Controls and Initial Startup OperationMaintenance Pump MaintenanceTroubleshooting IndexOperation and Maintenance Manual Introduction Operation and Maintenance Manual System Description Specifications Technical Information 355 SCDTechnical Information 255 NCD Physical Specifications Power requirementsVoltage Theory of Operation Sulfur Chemiluminescence DetectorNitrogen Chemiluminescence Detector Dual Plasma Controller Dual Plasma Burner with the 355 SCDDescription of Major Components Dual Plasma BurnerCross-Section of the Dual Plasma Burner for the 355 SCD Cross-Section of the Dual Plasma Burner for the 255 NCD Ozone Generator Chemiluminescence Reaction Cell and Photomultiplier Tube355 SCD Left Side 355 SCD Right Side 255 NCD Left Side View Pressure Transducer Vacuum PumpFID Adapter Optional Chemical TrapOil Coalescing Filter NCD Reaction CellNCD Photomultiplier Tube and Cooler Schematic for 355 SCD Schematic for 255 NCD, in Nitrogen Mode Schematic for 255 NCD, in Nitrosamine Mode Operation and Maintenance Manual Installation Overview Power Requirements Selecting a LocationEnvironmental Considerations Combustion Gas RequirementsTwo-stage pressure regulators Venting Gases Required Installation Tools Unpack and Inspect the InstrumentSet Up the Vacuum Pump Installing the Edwards RV5 Pump Oil-Sealed Vacuum PumpWA R N I N G Ard RV5 Oil-Sealed Vacuum Pump and Associated Traps Front Side RV5 Oil- Sealed Vacuum Pump and Associated Traps Top Setting the Gas Ballast Position RV5 Installing the Welch Dry Piston Vacuum Pump Operation Notes Welch Pump Welch Dry Piston Pump Operation and Maintenance Manual Connect the Power Cord SCD 230 V Unit Rear Panel DiagramInstall the Dry Compressed Air or O2 Supply Install the Signal Output Cables Install the Dual Plasma Burner Additional informationInstall the Dual Plasma Controller Dual Plasma Controller Rear PanelInstall Column Connections Capillary ColumnsPacked Columns and Columns with an Outside Diameter 0.8 mm Install the Transfer Line Front Panel Controls and Initial Startup Power Controls Detector Front Panel ControlsSignal Controls Display Output ControlsDual Plasma Controller Controls Dual Plasma Controller Front PanelInitial Startup Vacuum TestRecorder Test Detector Interface Setup Initial CheckoutIgnition Operation Start-Up Procedure Column Bleed Detector OperationDetector Stability and Response CokingContaminated Gases Fluctuating PressuresTypical Operating Conditions Typical Operating ConditionsDetection Limits Expected Detection Limits for Chromatographic ConditionsInstrument Shut-Down Daily ShutdownComplete Shutdown Using the 255 NCD in Nitrosamine Mode Special Operating ModesOperation and Maintenance Manual Operation and Maintenance Manual Maintenance Pump Maintenance Operating Life of Components for Edwards RV5 Vacuum PumpCleaning the Detector Changing the Oil Mist Filter RV5 Reaction Cell Cleaning EquipmentReaction Cell, PMT Housing and PMT Socket WA R N I N G Flow Sensor Calibration Detector Sensitivity MDLSCD Proper Ferrule Orientation to the Large Ceramic Tube Orientation of the Double Taper Ferrule Tightening the Heater Swivel Nut Operation and Maintenance Manual NCD Proper Ferrule Orientation to the Large Quartz Tube Burner Assembly Detail Tube Replacement for the SCD Positioning the Upper Tube in the Union Fitting 100 Operation and Maintenance Manual Operation and Maintenance Manual 101 Tube Replacement for the NCD Operation and Maintenance Manual 103 NCD Tube Replacement Detail Troubleshooting Solving Detector Problems Vacuum Pump Fuse Power ProblemsDetector Fuse Dual Plasma Controller FusesFuse Positions on the Power Supply Board Ozone Generation Problems High Voltage TransformerPlugged Restrictor Lines Response Problems Temperature Reading Problems Diagnosing General Problems Troubleshooting Detector IssuesDetector gases Troubleshooting Pump Issues Troubleshooting Burner Issues Index Agilent Technologies, Inc