XES Synergix 8825/8830/8850/8855 Digital Solution User Guide | 78 |
Main Menu (continued)
Timers
The TIMERS option of the CONFIGURATION menu allows you to set the values for the
The timers are as follows:
•FEATURE – Controls how long the current feature parameters remain in effect after the last key press, scan completion, or insertion of a document into the Scanner. The FEATURE timer can be set between 0 and 99 minutes. The factory default is 5 minutes. A value of 0 means that the feature will never time out.
NOTE: To prevent images from being lost, feature
•PRINTER INTERRUPT – Controls how long the Printer remains in the interrupted state with no interruption at the Scanner Control Panel. This timer pertains to print jobs that have been interrupted to allow a copy job to process. The allowed range is 1 to 99 minutes. The factory default is 1 minute.
•FILE DELETION – Specifies the maximum amount of time a scanned image file remains on the file system before being deleted. This timer pertains only to files scanned when the Synergix Digital Solution is in the READY TO SCAN mode.
This timer can be set between 1 and 24 hours in increments of 1 hour. When a file is scanned in, it is given a time stamp. When the age of the file on the hard disk exceeds the value of the FILE DELETION timer, the file is automatically deleted to allow space for new files. The default value is 24 hours. After the files have been deleted, the directory will also be deleted if no other files are scanned to it.
To adjust a timer:
1.Press the Menu key. The MAIN MENU screen is displayed.
2.Press the Enter key to select CONFIGURATION. The CONFIGURATION menu screen is displayed.
3.Press the Next key until TIMERS is highlighted.
4.Press the Enter key to select TIMERS. The TIMERS screen is displayed.
TIMERS
FEATURE (0 − 99 MIN): 5
PRINTER INTERRUPT (1 − 99 MIN): 1
FILE DELETION (1-24 HR): 24
5.Press the Previous or Next key to highlight the desired timer.
6.Press the Enter key to select the highlighted timer.
7.Use the numeric keypad to enter the timer value.
8.Press the Enter key to confirm the value.
9.Repeat steps 5 through 8 if you want to set the value for additional timers.