1.If you are installing the NetWare Requester on a workstation, select Edit CONFIG.SYS and Copy All Files.... If the NetWare Requester is already installed on the workstation and only a driver update is needed, then select Only Edit CONFIG.SYS....
2.On the next panel, specify the name of the adapter driver: IBMTRPO.SYS.
3.When you get to the panel labeled Copy ODI LAN Driver files, select Copy only the default driver.
4.Follow the instructions on the panels to continue installation.
5.When Installation Complete appears in the Requester window, go to the Configuration menu and select This workstation....
6.Select Edit to accept the default location for the NET.CFG file.
7.In the edit box titled Current NET.CFG File Contents, type the following lines:
link driver IBMTRPO SLOT 10001
link support BUFFERS 8 4096
Notes:
a.See “Appendix F. Novell NetWare DOS ODI driver parameters” on page 77 for a complete list of parameters that you can specify in the NET.CFG file.
b.To enable source routing, changes will have to be made to the CONFIG.SYS file. Refer to Novell’s Workstation for OS/2 manual for instructions on how to enable source routing.
c.The lines in the NetWare Requester section of the CONFIG.SYS file must be in a certain order. Do not reorder the lines in this section of CONFIG.SYS. Refer to the Novell manuals for more information.
8.Select Save to complete the NetWare Requester installation.
9.Reboot the computer to apply the changes.
Note: To make changes in the NetWare Requester configuration,
10.Check for the following conditions to determine whether the adapter is working correctly and whether installation has been completed successfully:
v The device driver files loaded successfully. There are no error messages. v The adapter LEDs indicate normal operation: Green ON, Amber OFF.
If you experience problems, see “Chapter 4. Problem solving” on page 37.
DOS NDIS 2
Use the following procedure to install the DOS NDIS 2 device driver:
1.Insert the
2.Use your operating system documentation to install the driver (IBMTRP.DOS). This driver is located in the \dos subdirectory on both diskette and the
3.Modify the parameters, if needed. See “Appendix B. NDIS 2 device driver parameters” on page 53.