IBM 16/4 Token-Ring manual Appendix E. Novell NetWare Server messages

Page 81

IBMTRPO-xx-217:

A ring beaconing condition was detected while attempting to insert into the network.

Explanation: The token-ring network is not functioning correctly.

User Action: Contact your local network administrator to determine the status of your network, or try connecting again at a later time.

IBMTRPO-xx-218:

A duplicate network address was detected while attempting to insert into the network.

Explanation: The address specified for the NetAddress configuration parameter is being used by another adapter (ring station) on the network.

User Action: Modify the configuration file to change the Node parameter value being used for this adapter, or remove the Node parameter to allow the universally administered address to be used. Contact your local network administrator for assistance with choosing a new Node parameter value, or to have the conflicting adapter removed from the same token-ring network as this adapter.

IBMTRPO-xx-219:

A ring parameter failure occurred while attempting to insert into the network.

Explanation: The token-ring network is not functioning correctly.

User Action: Contact your local network administrator to determine the status of your network, or try connecting again at a later time.

IBMTRPO-xx-220:

The adapter was forced to remove itself while attempting to insert into the network.

Explanation: The token-ring network rejected the attempt by this adapter to connect to it.

User Action: Contact your local network administrator to determine the status of your network, or try connecting again at a later time.

IBMTRPO-xx-221:

A hardware failure occurred while attempting to open the adapter.

Explanation: A hardware error was detected when opening the adapter for network operation.

User Action: Run the diagnostics program. See “Running adapter diagnostics” on page 42.

IBMTRPO-xx-222:

A hardware failure occurred while attempting to open the adapter.

Explanation: A hardware error was detected when opening the adapter for network operation.

User Action: Run the diagnostics program. See “Running adapter diagnostics” on page 42.

IBMTRPO-xx-223:

The adapter cannot be opened in AutoSense mode if it is the only active station on the network.

Explanation: The DataRate configuration parameter is set to AUTO (which is also the default value if the parameter is not specified), but the adapter is the first station to open on the token-ring network.

User Action: This adapter is designed to not open onto the attached token-ring network if it is configured to use AutoSense detection and if it would have been the first active ring station.

The possible remedies are to try connecting again at a later time when at least one other ring station is active on the network (such as a network server), or to change the configuration value so that the DATARATE parameter is set to a specific ring-speed value of M16 or M4 and unload and load IBMTRPO to activate this configuration change.

Note that setting a specific value of M16 or M4 for the DataRate parameter will cause this adapter to establish the operational speed of the token-ring network if it is still the first active ring station, so consult with your local network administrator if necessary.

Appendix E. Novell NetWare Server messages 73

Image 81
Contents User’s Guide First Edition April Contents Appendix A. CD-ROM content and software packages If YOU Download or USE this Program YOU Agree to These Terms Vi IBM 16/4 Token-Ring PCI Management Adapter About this manual Who should read this manualHow this manual is organized Related publications Adapter installation checklist Automatic Configuration and Power Interface Acpi Package contentsEnvironment limitations on number of adapters Wake on LANPage IBM 16/4 Token-Ring PCI Management Adapter Installing the adapter hardware Installing the adapterSelecting adapter cables STP and UTP cables Software installation Operating System Directory Environment DOS with Windows Version Novell NetWare 3.12 ServerSTARTUP.NCF Server driver installation in new NetWare 3.12 ServerServer driver installation in existing NetWare 3.12 Server Select Edit STARTUP.NCF File and press Enter Novell NetWare 4.11 ServerServer driver installation in new NetWare 4.11 Server Server driver installation in existing NetWare 4.11 Server Software installation Novell NetWare 5.0 Server Select Driver Options → Configure network drivers Server driver installation in existing NetWare 5.0 ServerSelect Save parameters and load driver Novell Client DOS/WindowsOS/2 Ndis 2 device driver using Mpts OS/2 Novell NetWare Requester OS/2 Ndis 2 device driver using other installation programsDOS Ndis DOS Novell NetWare Requester 16-bit Windows NT Version Select Start → Settings → Control Panel Windows IBM 16/4 Token-Ring PCI Management Adapter Select Finish to continue the installation Select Device Manager Installing the driver when Windows 98 is already installed Windows This wizard searches for updated drivers for Adapter name Novell IntranetWare Client for Windows NT Updating the driver when Windows 2000 is already installedWindows for Workgroups with Ndis Novell Client for WindowsRunning Managed Driver Upgrade locally Option Explanation Running Managed Driver Upgrade remotelyIBM 16/4 Token-Ring PCI Management Adapter Starting the troubleshooting process Problem solvingUsing Troubleshooting Utility Symptom SolutionInstalling Troubleshooting Utility Starting Troubleshooting UtilityWindow / Tab Task Viewing adapter analysis information Status NDISHARDWARESTATUS-type Explanation Value Status NDIS8025RINGSTATE value ExplanationStatus Viewing the event log Running 4/16 Mbps diagnostics Running adapter diagnosticsUnderstanding the adapter LEDs and labels Amber Green Explanation Understanding the adapter LEDsUnderstanding the adapter labels Solving problems with driver installationAmber Green Explanation Action Environment Message Type and ActionSolving an adapter communication problem Using PcisetupDOS, Novell, Windows, or Windows 95 adapter driver not OS/2 Tech tips and frequently asked questionsWindows NT Contacting IBM product supportIBM 16/4 Token-Ring PCI Management Adapter Operating System Directory Appendix A. CD-ROM content and software packagesDiskette images Software packagesPackage Description Executable Image Description ExecutableProduct documentation IBM 16/4 Token-Ring PCI Management Adapter PROTOCOL.INI files, see on page 58 and on Appendix B. Ndis 2 device driver parametersValid values 14 to 18,000 Parameter ExplanationValid values 1 to Valid values 256 to 18Valid values 0 to TxPriMaxAuto DisablePeer Xxx.xxx.xxx.xxxPriorityValue Valid values PortNumberSection a Protocol Driver IBM TCP/IP V1.2 for DOS TCPIPnif LA10001 IBM PCI Token-Ring Adapter, Version Appendix C. Ndis 2 device driver messagesIBM 16/4 Token-Ring PCI Management Adapter Appendix C. Ndis 2 device driver messages User Action None User Action None LA10033 Adapter analysis code isLA10045 Could not find the PROTOCOL.INI file image LA10044 The Ndis 2.0 Protocol Manager could not be openedIBM 16/4 Token-Ring PCI Management Adapter Load Ibmtrpo line in the AUTOEXEC.NCF file Appendix D. Novell NetWare Server driver parametersAdapter Features document Token-Ring Adapter Features document Valid values 2 to RTTS=Parameter Explanation IBM 16/4 Token-Ring PCI Management Adapter User Action None IBMTRPO-xx-203 Adapter is using an LAA Appendix E. Novell NetWare Server messagesIBMTRPO-xx-202 Adapter UAA BIA is IBM 16/4 Token-Ring PCI Management Adapter Appendix E. Novell NetWare Server messages User Action None IBMTRPO-xx-233 Adapter analysis code is IBMRNIC.NLM IBM 16/4 Token-Ring PCI Management Adapter Appendix F. Novell NetWare DOS ODI driver parameters Following parameters can be configured in the NET.CFG fileM16 Valid values 9 toValid values NO, YES Appendix G. Notices Trademarks Safety Information IBM 16/4 Token-Ring PCI Management Adapter Appendix G. Notices IBM 16/4 Token-Ring PCI Management Adapter Electronic Emission Notices Federal Communications Commission FCC Statement Avis de conformité aux normes d’Industrie CanadaEuropean Norm EN Statement Other Electronic Emission Notices for UTP Media Hinweis zur Elektromagnetischen Verträeglichkeit EmvgIndustry Canada Class a Emission Compliance Statement Appendix G. Notices IBM License Agreement for Productivity Aids IBM Power Cord Part Used in These Countries NumberIf YOU Download or USE this Program YOU Agree to These Terms Protection and Security NetWare Network Computing Products from IBMLabel on documentation must also include the words IBM Warranty Warranty Period* LifetimeWarranty Service Production StatusLimitation of Liability Extent of WarrantyIBM 16/4 Token-Ring PCI Management Adapter Glossary Full-duplex. Synonym for duplex CRC. See cyclic redundancy check CRCLAN. See local area network LAN Open Systems Interconnection OSI reference Open Systems Interconnection OSI architectureSegment. See cable segment, LAN segment, ring segment IBM 16/4 Token-Ring PCI Management Adapter DOS IndexMpts TXPRIMAX= Txprithresh