Fujitsu B120 manual

Page 46
Image 46
Contents Primergy B120 Are there Page A26361-K646-Z102-1-7619 Primergy B120 Operating ManualPage Contents Contents System board FeaturesIntroduction Hard disk subsystemService and Support Introduction FeaturesPower supply High level of availability and failure protectionNotational conventions Technical dataElectrical data standard power supply IntroductionEnvironmental conditions StandardsMechanical data Noise levelImportant notes SafetyInstallation and operation Before operating the devicePoper operation of the system, warranty features Important notes SafetyBatteries Modules with electrostatic sensitive components CE certificateImportant notes Other important notesFCC Class B Compliance Statement Transporting the serverTake-back, recycling and disposal Disposal and recyclingEnvironmentally friendly product design and development Further information on environmental protectionPage Installation steps InstallationUnpacking the server Installation Instructions on connecting and disconnecting cablesSetting up the tower server Connecting cablesConnecting the tower server to the line voltage 125 240Installing rack-server in/removing from rack Connecting the monitor to the line voltageMounting the slide-in module Installation Installing the slide-in module Fitting spring nutsMounting cage nuts Connecting the rack server to the line voltage Installation Prepare the keyboard Prepare the keyboardConnecting devices to the server Tower RackConnecting devices to the server Preparation for use and operation Enabling access to the accessible drivesUnlocking/locking the tower server Enabling access to the hard disk drives Preparation for use and operationOperation controls Drive indicators IndicatorsOperation controls Switching the server on and off Monitor screenOther switch-on methods Server is switched offServer is switched on Specified switch-on time/switch-off timeConfiguration without ServerStart Configuring the serverConfiguration with ServerStart Installing the operating systemLocking the tower server Fitting the hard disk coverCleaning the server Locking the serverPage Opening and closing the server Opening and closing the tower serverOpening and closing the rack server Opening and closing the serverOpening and closing the rack server Page Property and data protection Page Server switches itself off Troubleshooting and tipsOperation indicator remains dark Screen stays blankFlickering stripes on the monitor screen Troubleshooting and tipsNo screen display or display drifts Floppy disk cannot be read or written System does not bootNo mouse pointer displayed on the screen Time and/or date is not correctDisk Array Controller configuration is incorrect Drives dead at system bootError messages on the screen Added drive defectiveSystem components and expansions Scsi hard disk subsystemRAID level 0 Scsi hard disk drivesSystem components and expansions RAID level 1 and 5 without standby hard diskFunction of the indicators Green indicator Replacement of Scsi hard disk drive during operationOrange indicator Installing/removing a Scsi hard disk drive Scsi platter for four 1-inch hard disk slide-in modules IDE drive Accessible drivesScsi drive Installing/Removing an accessible 5 ¼-inch drive Open the server see Opening and closing the serverChanging the floppy disk drive Removing/installing boards Installing/removing the chipDISK ChipDISK for RemoteViewConfiguring the chipDISK Replacing the system fan Adapter module System boardPage Index ECCIndex KeyboardSCSI-ID Troubleshooting and tips