System components and expansions | The SCSI hard disk subsystem |
The following applies if SCSI hard disk drives are operated on a disk array controller:
•RAID level 0 and 7
Rebuild is not possible. If a hard disk fails, its data is lost.
•RAID level 1 and 5 without standby hard disk
Rebuild on the new disk is carried out automatically when the old disk is swapped.
•RAID level 1 and 5 with standby hard disk
A standby hard disk is automatically enabled as a replacement for the defective hard disk and the data of the defective disk is rebuilt on the standby disk.
ÊRead the documentation for the new hard disk drive.
8.1.1 SCSI hard disk drives
The SCSI hard disks which can be ordered for the server are supplied already mounted in the hard disk carriers. The
!
A hard disk in the hard disk carrier may only be replaced by a service technician.
1 | 2 | 3 | 4 | 5 |
1 = Installation frame
2 = Indicators (green and orange)
3 = Handle for the locking and unlocking of the hard disk carrier
4 = Ridge for the application of a shield with the current drive identifier 5 = Blank insert
44 |