Fujitsu B120 manual Removing/installing boards

Page 59

Removing/installing boards

System components and expansions

8.3Removing/installing boards

Before installing or removing a board, please read the documentation supplied with the board.

ÊShut down the operating system.

ÊSwitch off the server, and disconnect it from the network.

ÊOpen the server (see "Opening and closing the server").

!

Switching off the server does not disconnect the device from the network. To completely

disconnect the device from the network, remove the power plug from the line voltage.

 

Ê Remove the cables from the board.

1

2

a

 

 

 

ÊRemove the fastening screw (1) and take out the board of the slot (2). If no board was installed, remove the rear slot cover plate.

Do not dispose of the rear slot cover plate. For cooling, protection against fire and in order ! to comply with EMC regulations, you must refit the rear slot cover plate if you remove the

board.

Ê Insert the board in the required slot on the system board and push it carefully into place. Make sure that the rear slot cover plate of the board is positioned in the groove (a).

Ê Fix the board using the fastening screw removed previously (2). Ê If necessary, plug the lines on the board.

Ê Close the server again (see "Opening and closing the server").

A26361-K646-Z102-1-7619

51

Image 59
Contents Primergy B120 Are there Page A26361-K646-Z102-1-7619 Operating Manual Primergy B120Page Contents Contents Hard disk subsystem FeaturesIntroduction System boardHigh level of availability and failure protection Introduction FeaturesPower supply Service and SupportIntroduction Technical dataElectrical data standard power supply Notational conventionsNoise level StandardsMechanical data Environmental conditionsBefore operating the device SafetyInstallation and operation Important notesBatteries Important notes SafetyPoper operation of the system, warranty features Other important notes CE certificateImportant notes Modules with electrostatic sensitive componentsTransporting the server FCC Class B Compliance StatementFurther information on environmental protection Disposal and recyclingEnvironmentally friendly product design and development Take-back, recycling and disposalPage Unpacking the server InstallationInstallation steps Connecting cables Instructions on connecting and disconnecting cablesSetting up the tower server Installation125 240 Connecting the tower server to the line voltageConnecting the monitor to the line voltage Installing rack-server in/removing from rackMounting the slide-in module Installation Fitting spring nuts Installing the slide-in moduleMounting cage nuts Connecting the rack server to the line voltage Prepare the keyboard Installation Prepare the keyboardTower Rack Connecting devices to the serverConnecting devices to the server Unlocking/locking the tower server Enabling access to the accessible drivesPreparation for use and operation Preparation for use and operation Enabling access to the hard disk drivesOperation controls Operation controls IndicatorsDrive indicators Monitor screen Switching the server on and offSpecified switch-on time/switch-off time Server is switched offServer is switched on Other switch-on methodsInstalling the operating system Configuring the serverConfiguration with ServerStart Configuration without ServerStartFitting the hard disk cover Locking the tower serverLocking the server Cleaning the serverPage Opening and closing the tower server Opening and closing the serverOpening and closing the server Opening and closing the rack serverOpening and closing the rack server Page Property and data protection Page Screen stays blank Troubleshooting and tipsOperation indicator remains dark Server switches itself offNo screen display or display drifts Troubleshooting and tipsFlickering stripes on the monitor screen Time and/or date is not correct System does not bootNo mouse pointer displayed on the screen Floppy disk cannot be read or writtenAdded drive defective Drives dead at system bootError messages on the screen Disk Array Controller configuration is incorrectScsi hard disk subsystem System components and expansionsRAID level 1 and 5 without standby hard disk Scsi hard disk drivesSystem components and expansions RAID level 0Orange indicator Replacement of Scsi hard disk drive during operationFunction of the indicators Green indicator Installing/removing a Scsi hard disk drive Scsi platter for four 1-inch hard disk slide-in modules Scsi drive Accessible drivesIDE drive Open the server see Opening and closing the server Installing/Removing an accessible 5 ¼-inch driveChanging the floppy disk drive Removing/installing boards ChipDISK for RemoteView Installing/removing the chipDISKConfiguring the chipDISK Replacing the system fan System board Adapter modulePage ECC IndexKeyboard IndexSCSI-ID Troubleshooting and tips