Notes on installing in the rack | Important information |
3.5Notes on installing in the rack
VCAUTION!
●For safety reasons, at least two people are required to install the rack model because of its weight and size.
●Never lift the server into the rack using the handles on the front panel.
●When connecting and disconnecting cables, observe the relevant instructions in the “Important Information” chapter of the technical manual for the corresponding rack. The technical manual is supplied with the corresponding rack.
●When installing the rack, make sure that the
●For safety reasons, no more than one unit may be removed from the rack at any one time during installation and maintenance work.
●If several units are simultaneously removed from the rack, there is a risk that the rack could tip over.
●The rack must be connected to the power supply by an authorized specialist (electrician).
●If the rack model is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector, the power supply's fuse protection must comply with the requirements for
30 | Operating manual | RX330 S1 |