Hardware installation Installing/removing the server in/from the rack
4.2Installing/removing the server in/from the rack
VCAUTION!
●Follow the safety instructions in chapter “Important infor- mation” on page 21 and section “Notes on installing in the rack” on page 30.
●At least two people are needed to position the server into/out of the rack.
●The rack can tip over when more than one unit is removed.
●The server may not occupy the top height unit of the rack (38 HU/42 HU PRIMECENTER Rack and/or DataCenter Rack), as otherwise boards or fans cannot be replaced even with the
Rack requirements
The rack systems from Fujitsu Siemens Computers (PRIMECENTER Rack and DataCenter Rack) support installation of PRIMERGY servers. Installation in most current rack systems from other manufacturers (3rd party racks) is also supported.
To accommodate the ventilation concept and ensure proper ventilation, any unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.
RX330 S1 | Operating manual | 35 |