Hardware installation Installing/removing the server in/from the rack
Racks with installation depth smaller/greater than 735 mm
The lengths of the telescopic rails have to be adjusted with respect to each other when installing in rack systems with an installation depth greater than/less than 735 mm. The length is adjusted with the spring element on the variable support
ÊSecure the telescopic rails as described in section “Installation in PRIME- CENTER/DataCenter Rack” on page 39.
ÊMount the server (see section “Inserting the server” on page 43) and route the cables as described in the rack manual.
4.2.3Inserting the server
1
a2
Figure 6: Preparing the server
ÊPlace the server rails on the three screws on both sides of the server (1) and slide the server rails forwards to secure them (2).
The safety spring (a) must engage with an audible click.
RX330 S1 | Operating manual | 43 |