Appendix D Connecting DC Power
Connecting DC Power to a CDE300
Step 6 Reconnect the +Return (red) and
Connecting DC Power to a CDE300
The CDE300 ships fully populated with three DC PMs installed in the PM slots on the rear of the chassis; three DC power cables are shipped separately. The chassis has one ground stud that provides building and PM grounding. The minimum cabling requirement for connecting DC power to a CDE300 is two PM connects, but it is recommended that you use all three PM connects. Figure
Figure | CDE300 Rear Panel | |
4 | 5 |
|
| 6 | 7 |
3 |
|
|
2 |
|
|
1 |
| 280160 |
|
| |
|
| 8 |
1 | PM 1 | 5 | +Return |
|
|
|
|
2 | PM 2 | 6 | PM ground |
|
|
|
|
3 | PM 3 | 7 | Building/PM ground stud |
|
|
|
|
4 | 8 | Building ground wire | |
|
|
|
|
Connect DC power to the CDE300 by performing the following steps:
Caution Make sure the DC power wires are not attached to the DC power source until all the ground wires are connected on the CDE.
Step 1 Insert one blue DC power cable connector into the blue port on each PM, making sure it is completely seated.
Step 2 Remove the nut and star washers from the Building/PM ground stud.