Chapter 2 Preparing to Install the Content Delivery Engines
Site Requirements
•When removing or installing a component, use any available handles, ejector levers, or captive installation screws. These devices prevent accidental removal, provide proper grounding for the system, and help to ensure that bus connectors are properly seated.
Caution For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohm (Mohm).
Environmental, Physical, and Power Specifications
The CDEs are tested to the environmental specifications indicated in Table
Table | Environmental Specifications Summary | |
|
|
|
Environment |
| Specification |
|
| |
Temperature, operating | 0 to 50°C (32 to 122° F) | |
|
|
|
Temperature, |
| |
|
| |
|
|
|
Altitude |
| 60 to 4000 m |
|
| |
Humidity, | 5 to 95%, noncondensing at temperatures of 23°C (73°F) to 40°C (104°F) | |
|
|
|
Table
Table
Height |
|
CDE100 | 1.75 inches (4.45 cm) |
CDE200 | 3.50 inches (8.90 cm) |
CDE300 | 4.75 inches (12.1 cm) |
CDE400 | 7.00 inches (17.8 cm) |
|
|
Width |
|
CDE100 | 19.00 inches (48.26 cm) |
CDE200 | 17.50 inches (44.45 cm) |
CDE300 | 17.25 inches (43.8 cm) |
CDE400 | 17.25 inches (43.8 cm) |
|
|
Depth |
|
CDE100 | 27.6 inches (70.10 cm) |
CDE200 | 28.5 inches (72.39 cm) |
CDE300 | 27.5 inches (69.9 cm) |
CDE400 | 26.5 inches (67.3 cm) |
|
|
Front clearance | 2.0 inches (7.6 cm) |
|
|
Side clearance | 1.0 inches (2.5 cm) |
|
|
Rear clearance | 3.6 inches (9.2 cm) |
|
|
Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide
|
| |
|