Extron electronic 300, PVS 400, 200 manual PoleVault Systems Installation Reference Information

Page 46

Reference Information

Specifications

For detailed specifications and warranty information of the PoleVault System components, refer to the device

manuals, or the product pages at www.extron.com.

Mounting hardware

PCM 240

Mounting

Drop ceiling mountable

Enclosure type

14 gauge steel/powder coated white

Plate dimensions

25.8" L x 8.0" W x 1.2" D (65.5 cm L x 20.3 cm W x 3.0 cm D)

Product weight

5.6 lbs (2.5 kg)

Listings

UL, CUL as an accessory, for use with UL Listed mount and projector

Compliances

CE, OSHPD anchorage pre-approval

Vibration

ISTA 1A in carton (International Safe Transit Association)

PMP 6

Material

Steel Pipe

Color/finishes

White or black powder coat

Pipe dimensions

6" length, 1.5"-11.5 NPT threads)

Product weight

1.0 lbs (0.5 kg)

Listings

UL, CUL as an accessory, for use with UL Listed mount and projector

Compliances

CE

Vibration

ISTA 1A in carton (International Safe Transit Association)

PMK 450

Mounting

Mountable to round projector mount pipes with an outer diameter of 1.85" to 1.95"

 

(4.7 cm to 5.0 cm) using included hardware

Maximum load

15 lbs (6.8 kg)

Enclosure type (material)

Metal

Enclosure dimensions

2.32" H x 12.25" W x 11.63" D (5.9 cm H x 31.1 cm W x 29.5 cm D)

Product weight

2.4 lbs (1.2 kg)

Listings

UL, CUL

Compliances

CE

Vibration

ISTA 1A in carton (International Safe Transit Association)

UPB 25

Material

Steel

General dimensions

Refer to UPB 25 Manual

Product weight

3.7 lbs (1.7 kg)

Maximum capacity

25 lbs (11.3 kg)

Listing

UL, CUL as an accessory, for use with UL Listed mount and projector

Compliances

CE

Vibration

ISTA 1A in carton (International Safe Transit Association)

NSpecifications are subject to change without notice.

2-34 PoleVault Systems Installation • Reference Information

Image 46
Contents PoleVault Systems Consignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschIntroduction PoleVault Systems Installation IntroductionFCC Class a Notice PoleVault System installation and wiring overview Introduction, contdRoom layout Typical classroom installationPoleVault Systems Installation Introduction Planning RoomLocation of the screen and projector Example of a classroom installationIntroduction Planning, cont’d ADA overhead and side clearance requirementsLocation of MediaLink Controller and Wall Plates Example classroom with four speaker installationType and location of the speakers Inventory Introduction Inventory OverviewIncluded items PoleVault System Devices and Hardware, contd PoleVault System Devices and Hardware, cont’dIntroduction Inventory Overview, cont’d PoleVault System Ceiling SpeakersOptional installation hardware Items not includedInstallation tools Outline of installation steps Installation OverviewPoleVault Systems Installation Installation Overview PCM 240 Projector Ceiling Mount Where it goes Screws up into PCMPoleVault Systems Installation Installation Stage PMP Projector Mounting PoleMark screen location 2c Install the PMP2d Screw the adjuster plate onto the PMP 1a Mark the screen locationVerify the image location Installation Stage One, cont’d2f Slide and lock the projector onto the adjuster plate 2e Attach the bracket to the projectorCut the ceiling tile InstallationUsing these dimensions, mark and cut a hole for 5d Screw the PMP into the mounting plate viewed from belowTighten the four T-bar securing screws on the PCM Secure the Projector Ceiling Mount to the ceiling6e Tighten the turnbuckles 6g Attach the safety cable to the PCM Install the ScreenPower outlet installation on PCM This stage involves installing the devices shown below Stage Two Install the Wall Plates and MLC 104 IPMLC 104 IP Plus MediaLink Controller PVS 204SA switcher Cables1d Features for mud ring installation Stage Two Install the Wallplates and MLC 104 IP PlusInstall mud rings MLC 104 IP Plus mud ringProjector communication cables from Signal Cable Label colorPull cables 2c Pull the cables at each locationInstallation Stage Two, cont’d Install wall platesTWire stripping lengths Install MediaLink Controller4a Connecting the MLC to the switcher An RS-232 cable or IR emitter cable, as 4c Connect to the LAN using a CAT 5 cableConnect the MLC to the projector with AppropriateConnections made to the MLC 104 IP Plus 4e Secure the MLC 104 IP Plus to the mud ringStage Three Install the PV SI 3C LP Ceiling Speakers PV SI 3C LP Ceiling SpeakersCut ceiling tile Installation Stage Three, cont’d Cable the speakersStereo or dual mono output using parallel speaker wiring Pole captive screw connector4c Wire the captive screw connector Dual mono output To terminate the cable, strip the end of the cableFinish speaker installation 5a Apply putty to speaker grillPVS 204SA PoleVault Switcher Stage Four Install the PMK 450 and the PVS 204SAThis stage covers installing the devices shown below PMK 450 Pole Mount KitSwitcher and projector cable overview Installation Stage Four, cont’dInstall the PMK 450 Pole Mount kit Pull the cables3c Wire the captive screw connector for the power supply Install the PVS 204SA switcherPMK 450 bottom plate and secure it using velcro 3d Set the DIP switches as desiredConnect the cables to the switcher Finish installing the Pole Mount kitBControl/power cable from the MLC 104 IP Plus PVS 204SA cable connections4d Replace projector on the adjuster plate 4c Attach and screw down rear plate1a Load Global Configurator 2 software Stage Five Configure the SystemConfigure the system Launch GC2. Click on Help, then Contents or press F1PoleVault Systems Installation Installation Stage 2c Check that an image is present, adjust as needed Installation Stage Five, cont’dLoosen all pivot screws and adjust the vertical angle Test the systemAdjust the configuration as necessary Final installationRelease the input button Open the sensor and loop a wire around the sensor Optional Accessory Installation PPCInstallation Procedure Priority Page Controller included parts Strip 3/16 of insulation from each conductor on the bare Connect the power supply via the PoleVault switcher Sensitivity knob adjustment Testing and Adjustment ProcedurePriority Page Controller Time DIP switch settings PoleVault Systems Installation Reference Information Reference InformationWall or furniture mountable with included Decora wall plate Lbs 0.1 kgInstallation Reference Information, cont’d Page Extron USA West