Mounting (Rack)

Mount your equipment in either a 2-post or 4-post rack or rack enclosure. The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications.

Note: The illustrations may differ from your model.

4-Post Mounting

1The included plastic pegs A will temporarily support the empty rackmount shelves B while you install the permanent mounting hardware. Insert a peg near the center of the front and rear bracket of each shelf as shown. (Each front bracket has 6 holes and each rear bracket has 3 holes.) The pegs will snap into place.

After installing the pegs, expand each shelf to match the depth of your rack rails. The pegs will fit through the square holes in the rack rails to support the shelves. Refer to the rack unit labels to confirm that the shelves are level in all directions. Note: The support ledge of each shelf must face inward.

2Secure the shelves B to the mounting rails permanently using the included screws and cup washers C as shown. Place the cup washer between the screw and the rack so that the screw enters the wider opening of the cup washer first.

Place 4 screws total at the front and 4 screws total at the back.

Tighten all screws before proceeding.

Warning: Do not attempt to install your equipment until you have inserted and tightened the required screws. The plastic pegs will not support the weight of your equipment.

3Attach your equipment’s mounting brackets to the forward mounting holes of the

cabinet using the hardware included with your equipment. The mounting bracket “ears” should face forward. (Some equipment may have pre-installed or integral mounting brackets.)

4With the aid of an assistant (if necessary), lift your equipment and slide it into the shelves. Attach the equipment mounting brackets to the forward mounting rails with user-supplied screws and washers D . Tighten all screws securely.

4

B

A

1

B

2 C

3

D

4

A

C

D

12-12-037-93-3088-B.indb 4

12/26/2012 3:47:22 PM

Image 4
Contents SmartPro 2U Rackmount Not suitable for mobile applicationsImportant Safety Instructions UPS Location WarningsUPS Connection Warnings Equipment Connection WarningsBattery Warnings External Battery Connection WarningsMounting Rack Post MountingMounting Tower Quick Installation Turn the UPS onUSB and RS-232 Serial Communications Optional InstallationEPO Port Connection External Battery Connection Select Models Basic Operation Mode ButtonLCD Interface 12-12-037-93-3088-B.indb 12/26/2012 34731 PM Basic Operation Display Power Conditions Minutes Load Wattage KWH/DayEnable/Disable Alarm Control Menu OptionsLCD Brightness Self-testPower Sensitivity On Battery EventsAVR Events External Battery Setting Control Select Models Factory Mode ResetOther UPS Features Rear Panel AC Outlets All models include Nema 5-15R and/or NemaService Storage and ServiceStorage Battery Replacement Screws Screws Remove Battery Retention Plate Connect Batteries Always ensure that the batteryThem directly into the UPS cabinet Black-to-black and red-to-redWarranty Registration Two symbols are used on the label. V~ AC Voltage DC Voltage­Salida de Onda Sinusoidal de 120V Capacidades 2200VA-3000VA No adecuado para aplicaciones móvilesInstrucciones de Seguridad Importantes Advertencias para la Ubicación del UPSAdvertencias para la Conexión del UPS Advertencias sobre la conexión de equiposAdvertencias para la Conexión de la Batería Externa Advertencias sobre las bateríasNo utilice el UPS sin baterías Instalación Rack Instalación en 4 PostesInstalación Torre Instalación Rack continuaciónInstalación en 2 Postes Instalación Rápida Conecte el UPS en un tomacorriente de un circuito dedicadoEnchufe su equipo en el UPS Encienda el UPSComunicación Serial RS-232 y USB Instalación OpcionalConexión de Puerto EPO Conexión de Baterías Externas Instalación Opcional continuaciónDel UPS, en Operación Básica Interfaz de LCDACTIVAR-DESACTIVAR Alarma Operación Básica continuaciónOperación Básica continuación Estimado Autonomía Estimado Minutes Watts de Carga KWH/Día Desplegado de las Condiciones de EnergíaBatería Activar/Desactivar Alarma Opciones del Menú de ControlBrillo del LCD AutodiagnósticoEventos de AVR Eventos de Batería en UsoSensibilidad de Energía Control de Calibración de Batería Externa Modelos Selectos Mensajes de ErrorRestablecimiento del Modo de Fábrica Otras Características del UPS Panel Posterior Almacenamiento Almacenamiento y ServicioServicio Reemplazo de las Baterías Reemplazo de Baterías 12-12-037-93-3088-B.indb 12/26/2012 34815 PM Avisos Nota Sobre EtiquetadoSortie sinusoïdale de 120 V Capacités de 2 200 à 3 000 VA Ne convient pas aux applications mobilesAvertissements concernant l’emplacement de l’ASC Consignes de sécurité importantesAvertissements concernant la connexion de l’ASC Avertissements concernant la connexion de l’équipementAvertissements concernant la batterie Montage bâti Montage sur bâti à 4 montantsMontage tour Montage bâti suiteMontage sur bâti à 2 montants Installation rapide Brancher l’ASC dans une prise d’un circuit dédiéBrancher votre équipement dans l’ASC Mise sous tension de l’ASCPorts de communication de série USB et RS-232 Installation en optionConnexion au port EPO Installation en option suite Connection de batterie ExterneBouton « Mode » Commande »Fonctionnement de base Interface ACLACTIVATION-DÉSACTIVATION DE Lalarme Fonctionnement de base suiteIcône MIN Indique des unités de minutes Estimée en minutes Wattage de la KWh / jour Affichage des conditions de puissanceCharge La batterie Options de menu de commande Alarme activée / désactivéeCommande de défilement Luminosité ACLAVR Events événements AVR On Battery Events événements en mode batterieSensibilité à la puissance Réinitialisation du mode Factory usine Message derreurAutres fonctions de lASC panneau arrière Entreposage et service EntreposageRemplacement des batteries Ajouter de nouvelles batteries 12-12-037-93-3088-B.indb 12/26/2012 34845 PM Avis Numéros d’identification de conformité aux règlements12-12-037 93-3088RevF