IMAGE menu

IMAGE menu

From the IMAGE menu, items shown in the table below can be performed.

Select an item using the ▲/▼ cursor buttons on the projector or remote control, and press the ► cursor button on the projector or remote control, or ENTER button on the remote control to execute the item. Then perform it according to the following table.

Item

Description

 

 

 

Using the ▲/▼ buttons switches the mode for aspect ratio.

 

For an RGB signal

 

NORMAL ó 4:3 ó 16:9 ó 16:10 ó REAL

 

For an HDMI signal

ASPECT

NORMAL ó 4:3 ó 16:9 ó 16:10 ó 14:9 ó REAL

For a Video signal, S-video signal or Component video signal

 

 

4:3 ó 16:9 ó 16:10 ó 14:9 ó REAL

 

For no signal

 

4:3 (fixed)

 

• The NORMAL mode keeps the original aspect ratio of the signal.

 

Using the ▲/▼ buttons adjusts the over-scan ratio.

OVER SCAN

Large (It reduces picture) ó Small (It magnifies picture)

• This item can be selected only for a video, s-video, component and HDMI signal.

 

• When this adjustment is too large, certain degradation may appear

 

at the frame area of the picture. In such a case, please adjust small.

Using the ▲/▼ buttons adjusts the vertical position.

 

Up ó Down

 

Over-adjusting the vertical position may cause noise to appear on the screen. If this

V POSITION

occurs, please reset the vertical position to the default setting. Pressing the RESET

button when the V POSITION is selected will reset the V POSITION to the default setting.

When this function is performed on a video signal, s-video signal, or component video signal of 480i@60 or 576i@50 input the range of this adjustment depends on the OVER SCAN (above) setting. It is not possible to adjust when the OVER SCAN is set to 10.

This item cannot be selected for an HDMI signal.

Using the ▲/▼ buttons adjusts the horizontal position.

 

Left ó Right

 

Over-adjusting the horizontal position may cause noise to appear on the screen. If this

H POSITION

occurs, please reset the horizontal position to the default setting. Pressing the RESET

button when the H POSITION is selected will reset the H POSITION to the default setting.

When this function is performed on a video signal, s-video signal, or component video signal of 480i@60 or 576i@50 input the range of this adjustment depends on the OVER SCAN (above) setting. It is not possible to adjust when the OVER SCAN is set to 10.

This item cannot be selected for an HDMI signal.

(continued on next page)

30

Image 30
Contents About this manual Thank you for purchasing this projectorTrademark acknowledgment Contents Contents of package Fastening the lens coverHOT Part namesProjector 10 9Control panel Rear panelLaser pointer &13 It is a beam outlet Remote controlBack Remote control Enter button to push down the center pointSetting up Arrangement On a horizontal surfaceSuspended from the ceiling Security bar Anti-theft chain or wire Security slot Adjusting the projectors elevatorUsing the security bar and slot To loose an elevator foot Pull up the elevator knobWiht an Connecting your devicesMonitor VCR/DVD playerConnecting your devices About Plug-and-Play capabilityConnecting power supply Connector of the power cord to the outletLaser pointer Remote controlInstalling the batteries Hitachi MAXELL, Part No.LR6Front and top sensors About the remote control signalChanging the frequency of remote control signal Back sensorUsing as a wired remote control Using as a simple PC mouse & keyboardTurning off the power Power on/offTurning on the power STANDBY/ON button Power indicator Power switchOperating Adjusting the volumeSelecting an input signal Temporarily muting the soundSearching an input signal Selecting an input signalSelecting an aspect ratio Using the automatic adjustment feature Adjusting the zoom and focusAdjusting the lens shift  For a video signal and s-video signalAdjusting the position Correcting the keystone distortionsUsing the magnify feature Freezing the screenTemporarily blanking the screen Using the menu function Easy MenuEnter button Using the menu function Advanced MenuAuto Picture ModeAspect KeystoneEasy Menu Picture menu GammaPicture menu Color TempMY Memory Active IrisLOAD-1, LOAD-2, LOAD-3, LOAD-4 SAVE-1, SAVE-2, SAVE-3, SAVE-4Image menu Over ScanPosition Image menu PhaseAuto Adjust SizeVideo NR Input menuProgressive 3D-YCSVideo Format Input menuComponent HdmiRGB Resolution Setup menu Setup menu Monitor OUTAudio menu Using the /// buttons adjusts the menu position Screen menuBlank Screen menu Start UPCapturing error has occurred. Please try again MyScreenMyScreen registration is finished Message Template Using / buttons switches the mode forTemplate screen. The selected template pattern To the Template function is pressed Option menu Auto SearchAuto on Option menu Auto OFFLamp Time MY Source ServiceMY Button FanspeedGhost Filter MessageLens Type Remote Receiv Factory ResetKEY Lock Remote FreqChanging the Password Using Security FeaturesInputting the Password SecurityTurning on the MyScreen Password Function Using the MyScreen Password FunctionIf you have forgotten your Password Setting the PasswordDescription Security Using the PIN Lock FunctionTurning the Password off Registering the PIN CodeTurning Off the PIN Lock Function If you have forgotten your PIN CodeUsing the Transition Detector Function Setting the Transition Detector PasswordTurning On the Transition Detector Function Using the MY Text Password function Setting the Transition Detector offWriting the MY Text Turning on the MY Text Password Displaying the MY TextPassword and the screen will return to Setup Network menuNetwork menu Projector NameMY Image To switch the image displayedPress the or ESC button on the remote control Use the / buttonsInformation Mode Closed Caption menuDisplay ChannelLamp MaintenanceCase of replacement by yourself Type number = 456-8949H Replacing the lampLamp warning LampAir filter Type number = MU05661Internal clock battery For a holderFor B holder Inside of the projector Caring for the cabinet and remote controlOther care Caring for the lensTroubleshooting Related messagesRegarding the indicator lamps Regarding the indicator lamps Cooling fan is not operatingSignal cables are not correctly connected Electrical power cord is not pluggedPower switch is not set to the on position Signal source does not correctly workPhenomena that may be easily mistaken for machine defects Not properly adjusted Color settings are not correctly adjustedColor Space setting is not suitable Whisper function is workingSpecifications Warranty and after-serviceSpecifications Air filter MU05661Specifications 139 319 418 154 Unit mm