Barco 9200 owner manual How to find the correct values for the displayed item?

Page 29

Random Access Adjustment Mode

The file name will be displayed in the upper right corner. The following items can be adjusted :

Total quantity horizontal pixels Active quantity horizontal pixels Horizontal start in pixels

Horizontal period in µs (is automatically adapted during the instal- lation of a file with LOAD)

Total vertical lines (is automatically adapted during the installation of a file with LOAD)

Active vertical lines Vertical start in lines

Interlaced : toggle on/off (is automatically set to its correct position during the installation of a file with LOAD)

All settings can individually be changed. Push the control disc up or down to select an item. The color of the selected item will change and follow one of the three methods to change the value.

a. press ENTER to activate the digits and enter directly with the numeric keys on the RCU or local keypad the new value or

b. press ENTER to activate the digits. Push the control disc to the right or to the left to select the changing digit. Push the control disc up or down to scroll to desired digit. When finished press ENTER to confirm.

c. counting up or down by pushing the control disc to the right or to the left.

How to find the correct values for the displayed item?

During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are automatically measured and filled in in the menu table. These values will be available when starting up the EDIT procedure of an active file.

(Caution : Do not adjust these settings on an active file, they are used to identify the input source file.)

If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image. Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint: if the number of bars increase, adjust in the other direction).

The "Active Pixels" : determine the width of the window on the screen. This value is normally given in the source specifications. If not, adjust until full image is displayed (no missing pixels).

"Horizontal Start" : number of pixels between the beginning of the input signal and the start of the video information in the signal.

"Horizontal Period" : already filled in with the correct value when active file. (see caution above).

The "Vertical Total Lines" are already filled when an active file is selected to be edited.

The "Active Lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specification of the source. If not, adjust until full image height is displayed (no missing lines)

Vertical start : number of lines between the start of the input signal and start of the image on the screen.

Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).

Read AMDS

AMDS = automatic mode detection & synchronisation

During the installation of a file with LOAD, the system automatically measured the horizontal period, the total vertical lines and the interlaced mode.

When selecting Read AMDS, the system remeasures the above indicated items.

5975967 BARCOGRAPHICS 9200 070398

 

 

EDIT FILE

xga.s30

HORIZONTAL

 

 

 

TOTAL

 

 

1344 PIXELS

ACTIVE

 

 

1024 PIXELS

S T A R T

 

 

296

PIXELS

PERIOD

 

 

20.678 µS

VERTICAL (FIELD)

 

 

TOTAL

 

 

806

LINES

ACTIVE

 

 

768

LINES

S T A R T

 

 

36 LINES

INTERLACED

 

[OFF]

READ AMDS

 

 

 

OPTIONS

 

 

 

,

,

,

<ENTER>, <EXIT>

8-3

Image 29
Contents Graphics Page Date Rev Art. No 030798 R5975947 Barco Projection SystemsFederal communication commission FCC statement Table of Contents 10-2 10-110-4 11-1Unpacking Unpacking and DimensionsProjector dimensions Battery installation in the RCU Installation Guidelines How to install a projection lens? Where to install the projector?RGB Analog with Standard Sync Sync on Green or RGB Analog with TRI-LEVEL Sync Sync on Green orFront Panel Terminology ControlRC operating indication lights up when a button on Remote controlControl disc Key on RCU or + and keys cursor Local keypadInstallation Actual selected configuration will be highlightedConfiguration Front/table, front/ceiling, rear/table and rear/ceilingInstallation Set Up Switching on Power mains cord connectionConnections FusesSwitching off Switching to stand-byLamp Run Time Input connections269,2VIDEO,1387 Video/S-video input moduleRGB Analog Input Module 2032117B-Y S9,2,1387 Component Input ModuleRGB3S/RG3sB Input Module See Change Baudrate PC in chapter Service mode Set up of the baud rate for communication with a computerConnecting an IR Remote Receiver 800 to the projector Connecting a Rcvds 05 to the projectorConnecting a VS05 to the projector Controlling How to Use the RCU?Projector Address Point the front of the RCU to the reflective screen surfacePicture Controls with Direct Access How to Display a Projector Address?How to Program an Address into the RCU? Adjustment Mode Start UP of the Adjustment ModeStart up of the Adjustment Mode File Service Random Access Adjustment ModeStarting up the Random Access Adjustment Mode Load File File ServiceEdit File Edit file adaptation menu will be displayedHow to find the correct values for the displayed item? Example for clamp position trailing Copy RenameRename CopyFile Options Picture TuningDelete Sync slow/fast Color TemperatureStill Video Comparison with the green color valueGeometry GammaShift SizeBlanking Side KeystoneSide Keystone BlankingOptions Input Slots Starting up the Installation ModeConvergence ConvergenceRED on Green Internal Patterns ConfigurationStarting up the Service Mode Service ModeService Barcographics 9200 11-1Identification IdentificationHow to enable or disable the password function ? Change PasswordChange Language How to change the password ?Change Projector Address Change Baudrate PCLamp Power Reset Lamp RuntimeLamp Run Time History Barcographics 9200 11-5Preset Input Balance Panel AdjustmentsHz Tracking I2C diagnosisStandard Source SET UP Files 640 X 74,996 68,846 57,280 832 918 870 KHz MHz XGA72 1024 768 71,955 58,140 80,000 1376 808832 X 74,550 49,722 57,280 1152 667 624 640 X 55,370 24,370 21,060 864 440 400Lenses Focusing the lensLens Cleaning Procedure Lenses Projector with a 800 peripheral connected Projector without any 800 peripheral connectedSource numbers 81 13873525&8-6285&6&725