Barco 9200 owner manual Example for clamp position trailing

Page 30

Random Access Adjustment Mode

Options

Source Number : The source number of a non-active source can be changed to any other source number. This makes it possible to create a file for future source numbers.

Clamp Position : Clamping determines the black level of the signal. The clamp pulse can be related to the leading or the trailing edge of the sync pulse. Use the ENTER key to toggle between [leading] and [trailing].

Clamp Width : The width of the clamp pulse [1] or [2] Enter to toggle between [1] or [2].

Field Polarity Inverted :

The field polarity function is used for interlaced images. Both rasters of the image could be shifted in a wrong way (double lines are visilble in the image). This can be corrected by forcing the field polarity to [neg] or [pos].

Use the ENTER key to toggle between [yes] and [no].

Vertical Refresh [sync/async] : The way of updating the image information on the LCD panels.

For sources with a vertical frequency up to 60 Hz : the vertical refresh rate is the same as the vertical frequency of the incoming source. This is a necessity to project moving images without 'motion artifacts'. For stationary images with a vertical frequency up to 60 Hz it is still possible to use asynchronous refresh. When loading Pal, Secam, NTSC-files the synchronous mode is default, for all other sources below 60 Hz asynchronous mode is default.

For sources with a vertical frequency higher that 60 Hz : the vertical refresh is different than the vertical frequency of the incoming source. Synchronous refresh cannot be used.

Vertical Sync Polarity : [leading] or [trailing]

The vertical refresh can be synchronised with the leading sync edge or trailing sync edge. Default on [leading].

Toggling to [trailing] is only necessary for special applications where the trailing edge of the sync signal has to be taken as a reference. Use the ENTER key to toggle between [leading] or [trailing]

Press EXIT to leave the Edit File Option menu. A 'Confirm Edit File' menu will be displayed.

Press ENTER to confirm and to save the new settings or EXIT to return without saving the new entered settings.

 

EDIT FILE OPTIONS

Source number

 

1

Clamp

position

 

[leading]

Clamp

width

 

[1]

Field polarity inverted

[no]

Vertical

refresh

 

[sync]

Vert. sync

polarity

 

[leading]

 

 

Select with

or

 

<ENTER>

to

toggle

 

or

to change value

 

 

<EXIT>

to

return

Example for clamp position [trailing]

leading edge

trailing edge

Sync pulse

Clamp pulse

Clamp width

 

CONFIRM

 

 

EDIT FILE

 

Save

changes to

file

 

xga.c30?

 

<ENTER>

to

confirm

<EXIT>

to

return

8-4

 

5975967 BARCOGRAPHICS 9200 030798

 

Image 30
Contents Graphics Page Barco Projection Systems Date Rev Art. No 030798 R5975947Federal communication commission FCC statement Table of Contents 10-4 10-110-2 11-1Unpacking and Dimensions Projector dimensionsUnpacking Battery installation in the RCU Installation Guidelines RGB Analog with Standard Sync Sync on Green or Where to install the projector?How to install a projection lens? RGB Analog with TRI-LEVEL Sync Sync on Green orControl Front Panel TerminologyControl disc Key on RCU or + and keys cursor Remote controlRC operating indication lights up when a button on Local keypadConfiguration Actual selected configuration will be highlightedInstallation Front/table, front/ceiling, rear/table and rear/ceilingInstallation Set Up Connections Power mains cord connectionSwitching on FusesLamp Run Time Switching to stand-bySwitching off Input connectionsVideo/S-video input module 269,2VIDEO,1387RGB Analog Input Module Component Input Module 2032117B-Y S9,2,1387RGB3S/RG3sB Input Module Set up of the baud rate for communication with a computer See Change Baudrate PC in chapter Service modeConnecting a Rcvds 05 to the projector Connecting a VS05 to the projectorConnecting an IR Remote Receiver 800 to the projector Projector Address How to Use the RCU?Controlling Point the front of the RCU to the reflective screen surfaceHow to Display a Projector Address? How to Program an Address into the RCU?Picture Controls with Direct Access Start UP of the Adjustment Mode Adjustment ModeStart up of the Adjustment Mode Random Access Adjustment Mode Starting up the Random Access Adjustment ModeFile Service Edit File File ServiceLoad File Edit file adaptation menu will be displayedHow to find the correct values for the displayed item? Example for clamp position trailing Rename RenameCopy CopyPicture Tuning DeleteFile Options Still Video Color TemperatureSync slow/fast Comparison with the green color valueShift GammaGeometry SizeSide Keystone Side KeystoneBlanking BlankingOptions Starting up the Installation Mode Input SlotsConvergence ConvergenceRED on Green Configuration Internal PatternsService Service ModeStarting up the Service Mode Barcographics 9200 11-1Identification IdentificationChange Password How to enable or disable the password function ?Change Projector Address How to change the password ?Change Language Change Baudrate PCLamp Run Time History Reset Lamp RuntimeLamp Power Barcographics 9200 11-5Hz Tracking Panel AdjustmentsPreset Input Balance I2C diagnosisStandard Source SET UP Files 832 X 74,550 49,722 57,280 1152 667 624 KHz MHz XGA72 1024 768 71,955 58,140 80,000 1376 808640 X 74,996 68,846 57,280 832 918 870 640 X 55,370 24,370 21,060 864 440 400Focusing the lens Lens Cleaning ProcedureLenses Lenses Projector without any 800 peripheral connected Projector with a 800 peripheral connectedSource numbers 81 13873525&8-6285&6&725