2.6802.1Q VLAN
IEEE 802.1q
Currently the switch supports up to 32
Warning !!!
Incorrect configuration of Tagged VLAN can create a situation where the web interface of the switch cannot be accessed. This can occur when the PVID of the port you are using or the VID of the VLAN group the port belongs to is not on the same as the CPU PVID, and the port is configured to drop untagged ingress frames.
The CPU port (this is not a physical port) is a member of PVID 1 by default.
To adjust the CPU port PVID settings, select the port via port number 25. (Console only option) ie. VP then 25 will display PVID = 1
In the case that you do configure this state and lock the web interface out, then you can recover by connecting to the
VE - Enable/Disable 802.1Q VLAN
VF – Get 802.1Q VLAN Enable Setting
VV– Set PVID VP – Get PVID
19