Allied Telesis AT-DC2552XS, AT-PWR06, AT-FAN06 manual Led Fan

Page 19

AT-DC2552XS

Physical

Description

Stack Installation Guide for AT-2552XS L2 Data Center Switch

The AT-DC2552XS L2 Data Center Switch physical description is as follows:

AT-DC2552XS Front Panel

The front panel of the AT-DC2552XS is shown in Figure 1 on page 19.

Blank

Covers

Fan 1

LED

[Top of Chassis]

Fan 2

LED

PS 1

FAN 1

FAN 2

PS 2

Slot

Slot

Slot

Slot

Figure 1. AT-DC2552XS Front Panel View

Blank Covers - When the switch is shipped from the factory, four blank covers are installed.

-Two blank covers for the power supply slots (PS 1/PS 2)

-Two blank covers for the two fan module slots (FAN 1/FAN 2)

Warning

To insure proper cooling and air flow within the chassis, the blank covers should not be removed unless an AT-PWR06 power supply module and the AT-FAN06 fan modules are installed in their place.

The power unit slots (PS 1/PS 2) are for the installation of the AT-PWR06 power supply module. These slots are located on the far right and far left sides of the chassis.

A second AT-PWR06 power supply module may be installed for redundancy, but is not required for normal operation of the switch.

With a redundant power supply configuration, you can replace one of the two power supply modules without turning off the primary power supply. Each AT-PWR06 power supply module that is installed in the chassis is hot-swappable. Refer to “Installing and Replacing AT-PWR06 Power Supply Module” on page 48 for the installation procedure.

19

Image 19
Contents Installation Guide Page Tick Electrical Safety and Emissions StandardsTranslated Safety Statements Contents Page Figures Figures Tables Tables Preface Document Conventions Contacting Allied Telesis Preface Chapter OverviewFunctions AT-DC2552XS FeaturesInstallation Options  AT-QSFPSR 40GBASE-SR4 MPO Optional QSFP+ TransceiversLED FAN LEDAT-DC2552XS Rear Panel Stack Installation Guide for AT-2552XS L2 Data Center Switch Cable Type 10Mbps 100Mbps 1000Mbps LED LEDsQSFP+ LEDs QSFP+ LED is described in Table Fault PowerLink Link ACT LEDFAN2 FAN1AC OK Console Port AT-PWR06 Power Supply Module Stack Installation Guide for AT-2552XS L2 Data Center Switch AT-FAN06 Fan Module Beginning the Installation Step Procedure Installation OverviewReviewing Safety Precautions Beginning the Installation Stack Installation Guide for AT-2552XS L2 Data Center Switch Beginning the Installation Planning the Installation AT-DC2552XS Switch Unpacking the SwitchAT-PWR06 Power Supply AT-FAN06 Fan Module Installing the Switch and Modules Installing the Switch on a Desktop Possible Bracket Locations Installing the Switch in an Equipment RackInstalling the Switch and Modules Mounting the Switch in an Equipment Rack Installing Power Supply Module Installing and Replacing AT-PWR06 Power Supply ModuleInsert AT-PWR06 Module Into Chassis Tighten AT-PWR06 Captive Screws Replacing Power Supply ModuleInstalling Power Supply Blank Cover Installing Fan Module Installing and Replacing AT-FAN06 Fan ModuleStack Installation Guide for AT-2552XS L2 Data Center Switch Replacing Fan Module Installing the SFP+ and QSFP+ Transceivers and Cables 10GBASE-LR Installing SFP+ Transceivers and Cables10GBASE-SR AT-SP10SRInstalling SFP+ Transceiver Removing SFP+ Dust Cover Installing a SFP+ Direct Attach Cables Installing the SFP+ and QSFP+ Transceivers and Cables 40GBASE-SR4 Installing QSFP+ Transceivers and CablesAT-QSFPSR Installing the SFP+ and QSFP+ Transceivers and Cables QSFP+ Mthtp Installing the SFP+ and QSFP+ Transceivers and Cables Powering the Switch Powering On the Switch Stack Installation Guide for AT-2552XS L2 Data Center Switch Turn Off the switch Managing the Switch Local Management Connecting the Console PortStack Installation Guide for AT-2552XS L2 Data Center Switch Remote Network Management NET Mgmt Cable InstallationStack Installation Guide for AT-2552XS L2 Data Center Switch Managing the Switch Troubleshooting Troubleshooting Stack Installation Guide for AT-2552XS L2 Data Center Switch Troubleshooting Appendix a Technical SpecificationsPhysical Specifications Environmental SpecificationsMtbf Power SpecificationsCertifications Quality and ReliabilityTX+ RX+ RJ-45 Twisted Pair Port PinoutsPinout Pair Stack Installation Guide for AT-2552XS L2 Data Center Switch Appendix a Technical Specifications