Allied Telesis AT-PWR06, AT-DC2552XS manual AT-FAN06 Fan Module

Page 32

Chapter 1: Overview

AT-FAN06 Fan Module

Installation of two AT-FAN06 fan modules are required in the AT-DC2552XS. Each AT-FAN06 fan module is equipped with two, forced air cooling fans The fans push air through the chassis from the front to the rear. The AT-FAN06 fan module is ordered and shipped separately from the AT-DC2552XS L2 Data Center Switch.

A view of the AT-FAN06 fan module is shown in Figure 10.

Captive Screws

 

 

Handles

Intake Air Vents

 

Figure 10. AT-FAN06 Fan Module

The components of the AT-FAN06 fan module are as follows:

Captive screws - The two captive screws secure the fan module to the chassis frame. See “AT-FAN06 Fan Module” on page 32 for the fan installation procedure.

Handles - The two handles are used to physically push or pull the AT-FAN06 fan module into and out of the chassis. See “AT-FAN06 Fan Module” on page 32 the fan installation procedure.

Intake Air Vents - The AT-FAN06 fan module has two fans which pull air through the intake air vents to cool the chassis components. The air is discharged through the rear panel exhaust air vents. See Figure 2 on page 20 for the location of the exhaust vents.

Warning

On both the AT-PWR06 power supply module and AT-FAN06 fan modules, keep the intake vents clear of any obstructions to insure proper cooling of the switch components.

32

Image 32
Contents Installation Guide Page Electrical Safety and Emissions Standards TickTranslated Safety Statements Contents Page Figures Figures Tables Tables Preface Document Conventions Contacting Allied Telesis Preface Overview ChapterAT-DC2552XS Features FunctionsInstallation Options Optional QSFP+ Transceivers  AT-QSFPSR 40GBASE-SR4 MPOLED LED FANAT-DC2552XS Rear Panel Stack Installation Guide for AT-2552XS L2 Data Center Switch Cable Type 10Mbps 100Mbps 1000Mbps LEDs LEDQSFP+ LEDs QSFP+ LED is described in Table Power FaultLink ACT LED LinkFAN1 FAN2AC OK Console Port AT-PWR06 Power Supply Module Stack Installation Guide for AT-2552XS L2 Data Center Switch AT-FAN06 Fan Module Beginning the Installation Installation Overview Step ProcedureReviewing Safety Precautions Beginning the Installation Stack Installation Guide for AT-2552XS L2 Data Center Switch Beginning the Installation Planning the Installation Unpacking the Switch AT-DC2552XS SwitchAT-PWR06 Power Supply AT-FAN06 Fan Module Installing the Switch and Modules Installing the Switch on a Desktop Installing the Switch in an Equipment Rack Possible Bracket LocationsInstalling the Switch and Modules Mounting the Switch in an Equipment Rack Installing and Replacing AT-PWR06 Power Supply Module Installing Power Supply ModuleInsert AT-PWR06 Module Into Chassis Replacing Power Supply Module Tighten AT-PWR06 Captive ScrewsInstalling Power Supply Blank Cover Installing and Replacing AT-FAN06 Fan Module Installing Fan ModuleStack Installation Guide for AT-2552XS L2 Data Center Switch Replacing Fan Module Installing the SFP+ and QSFP+ Transceivers and Cables Installing SFP+ Transceivers and Cables 10GBASE-SRAT-SP10SR 10GBASE-LRInstalling SFP+ Transceiver Removing SFP+ Dust Cover Installing a SFP+ Direct Attach Cables Installing the SFP+ and QSFP+ Transceivers and Cables AT-QSFPSR Installing QSFP+ Transceivers and Cables40GBASE-SR4 Installing the SFP+ and QSFP+ Transceivers and Cables QSFP+ Mthtp Installing the SFP+ and QSFP+ Transceivers and Cables Powering the Switch Powering On the Switch Stack Installation Guide for AT-2552XS L2 Data Center Switch Turn Off the switch Managing the Switch Connecting the Console Port Local ManagementStack Installation Guide for AT-2552XS L2 Data Center Switch NET Mgmt Cable Installation Remote Network ManagementStack Installation Guide for AT-2552XS L2 Data Center Switch Managing the Switch Troubleshooting Troubleshooting Stack Installation Guide for AT-2552XS L2 Data Center Switch Troubleshooting Technical Specifications Physical SpecificationsEnvironmental Specifications Appendix aPower Specifications CertificationsQuality and Reliability MtbfRJ-45 Twisted Pair Port Pinouts TX+ RX+Pinout Pair Stack Installation Guide for AT-2552XS L2 Data Center Switch Appendix a Technical Specifications