Allied Telesis AT-FAN06, AT-PWR06 manual AT-DC2552XS Rear Panel

Page 20

Chapter 1: Overview

Note

The AT-PWR06 power supply module is sold and packaged separately from the AT-DC2552XS L2 Data Center Switch.

The fan module slots (FAN 1/FAN 2) are for the installation of the AT-FAN06 fan module. These slots are located on the center right and center left of the chassis.

Two AT-FAN06 fan modules are required in the chassis for normal operation of the switch. Refer to “Installing and Replacing AT- FAN06 Fan Module” on page 52 for the installation procedure.

Note

The AT-FAN06 fan module is sold and packaged separately from the AT-DC2552XS L2 Data Center Switch.

Fan LEDs - The fan LEDs FAN 1 (upper LED) / FAN 2 (lower LED) display the status of the fan modules. They are located in the center of the chassis between the fan module slots. See Figure 6 on page 27 for the functional description of these LEDs.

AT-DC2552XS Rear Panel

The rear panel of the AT-DC2552XS is shown in Figure 2.

 

NET MGMT Port LEDs

 

NET MGMT Port

 

 

 

 

Exhaust Air Vents

(ETH0)

QSFP+ Slot LEDs

[Top of Chassis]

48 SFP+ Slots

(Ports 1 - 48)

SFP+ Slot LEDs

4 QSFP+ Slots

(Ports 49 - 64)

Console Port

Power/Fault LED

Figure 2. AT-DC2552XS Rear Panel

Exhaust Air Vents - Air is forced through the chassis by the fan modules and power supply modules and exits through the exhaust air vents on the top of the rear panel.

20

Image 20
Contents Installation Guide Page Electrical Safety and Emissions Standards TickTranslated Safety Statements Contents Page Figures Figures Tables Tables Preface Document Conventions Contacting Allied Telesis Preface Overview ChapterAT-DC2552XS Features FunctionsInstallation Options Optional QSFP+ Transceivers  AT-QSFPSR 40GBASE-SR4 MPOLED LED FANAT-DC2552XS Rear Panel Stack Installation Guide for AT-2552XS L2 Data Center Switch Cable Type 10Mbps 100Mbps 1000Mbps LEDs LEDQSFP+ LEDs QSFP+ LED is described in Table Power FaultLink ACT LED LinkFAN1 FAN2AC OK Console Port AT-PWR06 Power Supply Module Stack Installation Guide for AT-2552XS L2 Data Center Switch AT-FAN06 Fan Module Beginning the Installation Installation Overview Step ProcedureReviewing Safety Precautions Beginning the Installation Stack Installation Guide for AT-2552XS L2 Data Center Switch Beginning the Installation Planning the Installation Unpacking the Switch AT-DC2552XS SwitchAT-PWR06 Power Supply AT-FAN06 Fan Module Installing the Switch and Modules Installing the Switch on a Desktop Installing the Switch in an Equipment Rack Possible Bracket LocationsInstalling the Switch and Modules Mounting the Switch in an Equipment Rack Installing and Replacing AT-PWR06 Power Supply Module Installing Power Supply ModuleInsert AT-PWR06 Module Into Chassis Replacing Power Supply Module Tighten AT-PWR06 Captive ScrewsInstalling Power Supply Blank Cover Installing and Replacing AT-FAN06 Fan Module Installing Fan ModuleStack Installation Guide for AT-2552XS L2 Data Center Switch Replacing Fan Module Installing the SFP+ and QSFP+ Transceivers and Cables Installing SFP+ Transceivers and Cables 10GBASE-SRAT-SP10SR 10GBASE-LRInstalling SFP+ Transceiver Removing SFP+ Dust Cover Installing a SFP+ Direct Attach Cables Installing the SFP+ and QSFP+ Transceivers and Cables AT-QSFPSR Installing QSFP+ Transceivers and Cables40GBASE-SR4 Installing the SFP+ and QSFP+ Transceivers and Cables QSFP+ Mthtp Installing the SFP+ and QSFP+ Transceivers and Cables Powering the Switch Powering On the Switch Stack Installation Guide for AT-2552XS L2 Data Center Switch Turn Off the switch Managing the Switch Connecting the Console Port Local ManagementStack Installation Guide for AT-2552XS L2 Data Center Switch NET Mgmt Cable Installation Remote Network ManagementStack Installation Guide for AT-2552XS L2 Data Center Switch Managing the Switch Troubleshooting Troubleshooting Stack Installation Guide for AT-2552XS L2 Data Center Switch Troubleshooting Technical Specifications Physical SpecificationsEnvironmental Specifications Appendix aPower Specifications CertificationsQuality and Reliability MtbfRJ-45 Twisted Pair Port Pinouts TX+ RX+Pinout Pair Stack Installation Guide for AT-2552XS L2 Data Center Switch Appendix a Technical Specifications