Allied Telesis AT-PWR06, AT-DC2552XS Stack Installation Guide for AT-2552XS L2 Data Center Switch

Page 21

Stack Installation Guide for AT-2552XS L2 Data Center Switch

Warning

Keep the exhaust air vents clear of any obstructions to insure proper cooling of the switch components.

SFP+ Slots - There are 48 SPF+ slots (ports 1 - 48) on the rear panel. Each port supports communication speeds up to 10Gbps. The switch supports a variety of 10G SFP+ transceivers and direct attach cables.

The AT-DC2552XS L2 Data Center Switch only supports SFP+ transceivers in this product. Refer to “Installing SFP+ Transceivers and Cables” on page 56 for installation instructions of the SFP+ transceivers.

Note

Each SFP+ slot has a dust cover installed at the factory which should be left in place until a SFP+ transceiver is installed.

SFP+ Slot LEDs - Each SFP+ slot has a corresponding LED which displays the link and activity status of the port. Refer to Figure 3 on page 23 for the location of these LEDs and Table 2 on page 23 for their functional description.

QSFP+ Slots - There are four QSFP+ slots which support communication speeds up to 40 GB. These slots are numbered 49, 53, 57 and 61. Each slot may be configured as one 40 GB port or 4 X 10GB ports in the management software. Refer to Figure 4 on page 24 for the location of these LEDs and Table 3 on page 24 for their functional description. Refer to “Installing QSFP+ Transceivers and Cables” on page 61 for installation instructions.

Note

Each QSFP+ slot has a dust cover installed at the factory which should be left in place until an QSFP+ transceiver is installed.

Note

QSFP+ transceivers must be purchased separately. For more information about the list of supported QSFP+ transceivers, refer to “Optional SFP+ Transceivers” on page 17.

QSFP+ Slot LEDs - Each QSFP+ slot has a corresponding QSFP+ LED which displays the link and activity status of the QSFP + slots. Refer to “QSFP+ Slot LEDs” on page 24 for the functional description.

Power/Fault LED - The Status LED displays the overall status of the chassis, power supply modules and fan modules. Refer to

21

Image 21
Contents Installation Guide Page Tick Electrical Safety and Emissions StandardsTranslated Safety Statements Contents Page Figures Figures Tables Tables Preface Document Conventions Contacting Allied Telesis Preface Chapter OverviewFunctions AT-DC2552XS FeaturesInstallation Options  AT-QSFPSR 40GBASE-SR4 MPO Optional QSFP+ TransceiversLED FAN LEDAT-DC2552XS Rear Panel Stack Installation Guide for AT-2552XS L2 Data Center Switch Cable Type 10Mbps 100Mbps 1000Mbps LED LEDsQSFP+ LEDs QSFP+ LED is described in Table Fault PowerLink Link ACT LEDFAN2 FAN1AC OK Console Port AT-PWR06 Power Supply Module Stack Installation Guide for AT-2552XS L2 Data Center Switch AT-FAN06 Fan Module Beginning the Installation Step Procedure Installation OverviewReviewing Safety Precautions Beginning the Installation Stack Installation Guide for AT-2552XS L2 Data Center Switch Beginning the Installation Planning the Installation AT-DC2552XS Switch Unpacking the SwitchAT-PWR06 Power Supply AT-FAN06 Fan Module Installing the Switch and Modules Installing the Switch on a Desktop Possible Bracket Locations Installing the Switch in an Equipment RackInstalling the Switch and Modules Mounting the Switch in an Equipment Rack Installing Power Supply Module Installing and Replacing AT-PWR06 Power Supply ModuleInsert AT-PWR06 Module Into Chassis Tighten AT-PWR06 Captive Screws Replacing Power Supply ModuleInstalling Power Supply Blank Cover Installing Fan Module Installing and Replacing AT-FAN06 Fan ModuleStack Installation Guide for AT-2552XS L2 Data Center Switch Replacing Fan Module Installing the SFP+ and QSFP+ Transceivers and Cables 10GBASE-SR Installing SFP+ Transceivers and CablesAT-SP10SR 10GBASE-LRInstalling SFP+ Transceiver Removing SFP+ Dust Cover Installing a SFP+ Direct Attach Cables Installing the SFP+ and QSFP+ Transceivers and Cables Installing QSFP+ Transceivers and Cables 40GBASE-SR4AT-QSFPSR Installing the SFP+ and QSFP+ Transceivers and Cables QSFP+ Mthtp Installing the SFP+ and QSFP+ Transceivers and Cables Powering the Switch Powering On the Switch Stack Installation Guide for AT-2552XS L2 Data Center Switch Turn Off the switch Managing the Switch Local Management Connecting the Console PortStack Installation Guide for AT-2552XS L2 Data Center Switch Remote Network Management NET Mgmt Cable InstallationStack Installation Guide for AT-2552XS L2 Data Center Switch Managing the Switch Troubleshooting Troubleshooting Stack Installation Guide for AT-2552XS L2 Data Center Switch Troubleshooting Physical Specifications Technical SpecificationsEnvironmental Specifications Appendix aCertifications Power SpecificationsQuality and Reliability MtbfTX+ RX+ RJ-45 Twisted Pair Port PinoutsPinout Pair Stack Installation Guide for AT-2552XS L2 Data Center Switch Appendix a Technical Specifications