Powerware 9315 operation manual User-Selected Events, Messages Alarms

Page 76

User-Selected Events

Insert a check at each alarm or notice in the appropriate Group 1 or Group 2 block to indicate the configuration of your UPS.

INVERTER

Group

Group

INVERTER

Group

Group

MESSAGES --

1

2

MESSAGES --

1

2

ALARMS

 

 

NOTICES

 

 

 

 

 

 

 

 

Inverter AC Over

 

 

Inv. Logic Power Failed

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

Inverter AC Under

 

 

Bypass AC Over

 

 

Voltage

 

 

Voltage

 

 

 

 

 

 

 

 

Inverter Calibration

 

 

Bypass AC Under

 

 

Required

 

 

Voltage

 

 

 

 

 

 

 

 

Inverter Contactor (K3)

 

 

Bypass is Not Available

 

 

Failed

 

 

 

 

 

 

 

 

 

 

 

Inverter DC Over

 

 

Bypass Mode

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

Inverter Failure

 

 

Bypass Over

 

 

 

 

 

Frequency

 

 

 

 

 

 

 

 

Inverter Over

 

 

Bypass Under

 

 

Frequency

 

 

Frequency

 

 

 

 

 

 

 

 

Inverter Phase Rotation

 

 

Input Breaker (CB1)

 

 

 

 

 

Open

 

 

 

 

 

 

 

 

Inverter Setup

 

 

Battery Contactor (K2)

 

 

Required

 

 

Open

 

 

 

 

 

 

 

 

Inverter Under

 

 

Battery DC Under

 

 

Frequency

 

 

Voltage

 

 

 

 

 

 

 

 

100% Overload

 

 

Battery Discharged

 

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

125% Overload

 

 

Battery Not Charged

 

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

Over Temperature

 

 

Battery Voltage Low

 

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

Shutdown Imminent

 

 

Phase A Current Limit

 

 

 

 

 

 

 

 

Load Off

 

 

Phase B Current Limit

 

 

 

 

 

 

 

 

Bypass Contactor (K4)

 

 

Phase C Current Limit

 

 

Failed

 

 

 

 

 

 

 

 

 

 

 

Battery Contactor (K2)

 

 

Phase C Current Limit

 

 

Failed

 

 

 

 

 

 

 

 

 

 

 

Bypass Control Failed

 

 

 

 

 

 

 

 

 

 

 

Bypass Phase Rotation

 

 

 

 

 

 

 

 

 

 

 

Go To Bypass Active

 

 

 

 

 

 

 

 

 

 

 

Battery Ground Fault

 

 

 

 

 

 

 

 

 

 

 

68

Powerware 9315 (200 kVA ---300 kVA) Operation

 

164201036 Rev. D 041500

Image 76
Contents Uninterruptible Power Supply KVA 300 kVA Important Safety Instructions Table of Contents Starting and Stopping the UPS Maintaining the UPS System Responding to System Events List of Figures List of Tables Using This Manual IntroductionFor More Information Getting HelpTypical Powerware 9315 UPS System Getting StartedBattery Cabinet Looking Inside the UPSUPS Standard Features Monitor PanelOptions and Accessories Installation FeaturesSafety Considerations Output TransformerSymbols, Controls, and Indicators Risk of Electric ShockUnderstanding UPS Operation Normal Mode Path of Current Through the UPS in Normal ModeBypass Mode Path of Current Through the UPS in Bypass ModeBattery Mode Path of Current Through the UPS in Battery ModeMonitoring and Controlling UPS Operation Control Panel MonitorThis Page Intentionally Left Blank Using the Control Panel Starting and Stopping the UPSTo Place the UPS in Normal Mode To Shut Down the UPS from Normal Mode To Start the UPS in Bypass ModeThis Page Intentionally Left Blank Using the Monitor Panel UPS Monitor PanelUsing the LCD Screen Alarm NoneAdjusting the Contrast Using the PushbuttonsUsing the Load Off Pushbutton Reading the Status Indicators Using the Menu Options · SetupShows the Load Amps Meters screen Shows the Event History Log screen Shows the Active System Events screen Shows the Unit Statistics screen Shows the Mimic screen Time Setup Screen Port Setup Screen Using Features and Options Building Alarm MonitoringSummary Alarm Contacts Summary Alarm ContactsOptional Monitoring Accessories Remote Monitor PanelSystem Normal Battery Cabinets External Battery DisconnectRelay Interface Module Relay Interface ModuleSupervisory Contact Module Shutdown ImminentThis Page Intentionally Left Blank Serial Communications Locating the Communications Panel Communications PanelConnecting Equipment to a Serial Port Port 1 DE-9Port 2 DB-25 Configuring the Serial Ports Setup Serial Port 1 ScreenMode RateDefault Settings Data/StopHandshaking SaveTerminal Mode Printing Selected InformationEntire Log Ctrl + P Event History LogMeters Printout Ctrl + M System Information Printout Ctrl + aBattery Test Printout Ctrl + B APRSystem Configuration Mode Main Menu System ConfigurationProgram Building Alarms Enable/Disable Default Functions Customize Alarm Messages Program Unit NameAdjust Output Voltage Change PasswordBattery Test Setup WK DAY MON Hrmn 4 FRI MARCalibration Mode Computer ModeRemote Monitor Mode Modify Low Battery TimeThis Page Intentionally Left Blank Remote Notification Remote Notification Features Call Answer Description of OperationCall Out Housekeeping Hardware Requirements Configuring the Modem Basic Modem ConfigurationConfiguring the Modem to Call a Remote Computer Configuring the Modem to Call a Numeric Pager Configuring the Modem to Answer Incoming Calls Final Modem Configuration UPS Setup Configuration SaveMessages Alarms User-Selected EventsRectifier Monitor Important Safety Instructions Maintaining the UPS System164201036 Rev. D Performing Preventive Maintenance Maintenance TrainingThis Page Intentionally Left Blank Product Specifications System InputSystem Output Nominal +/-- 5%Environmental Specifications Battery SpecificationsThis Page Intentionally Left Blank System Event Horns Responding to System EventsSystem Event Lights Inverter Messages -- Alarms Inverter Messages -- Notices System Event MessagesInverter Messages Inverter Status Messages Commands Rectifier Status Messages Resetting the UPS System after Load Off Using the Load OFF PushbuttonTo Use the Load OFF Pushbutton This Page Intentionally Left Blank