Powerware 9315 System Event Messages, Inverter Messages -- Alarms Inverter Messages -- Notices

Page 88

System Event Messages

When a system event occurs, a message is added to the Event History Log. A message may also appear on the Monitor Panel of the UPS. The Event History Log contains all system event messages, whether or not they were displayed on the Monitor Panel.

INVERTER MESSAGES -- ALARMS

INVERTER MESSAGES -- NOTICES

 

 

Inverter DC Over Voltage

Bypass AC Over Voltage

Clear Inverter DC Over Voltage

Clear Bypass AC Over Voltage

 

 

Inverter AC Over Voltage

Bypass AC Under Voltage

Clear Inverter AC Over Voltage

Clear Bypass AC Under Voltage

 

 

Inverter AC Under Voltage

Bypass Over Frequency

Clear Inverter AC Under Voltage

Clear Bypass Over Frequency

 

 

Inverter Over Frequency

Bypass Under Frequency

Clear Inverter Over Frequency

Clear Bypass Under Frequency

 

 

Inverter Under Frequency

Battery DC Under Voltage

Clear Inverter Under Frequency

Clear Battery DC Under Voltage

 

 

Over Temperature Shutdown

Battery Not Charged

 

Clear Battery Not Charged

 

 

100% Overload Shutdown

Bypass is Not Available

 

Bypass is Available

 

 

125% Overload Shutdown

Input Breaker Open

 

 

Battery Cont. (K2) Failure

Inv. Logic Power Failure

 

Clear Inv. Logic Pwr Fail.

 

 

Bypass Cont. (K4) Failure

Phase A Current Limit

 

Phase B Current Limit

 

Phase C Current Limit

 

 

Bypass Control Failure

Load Transferred to Bypass

 

 

Inverter Cont. (K3) Failure

 

 

 

Inverter Failure

 

 

 

Load Off

 

 

 

Inverter Cont. (K3) Open

 

 

 

Bypass Cont. (K4) Failure

 

 

 

80

Powerware 9315 (200 kVA ---300 kVA) Operation

 

 

164201036 Rev. D 041500

Image 88
Contents Uninterruptible Power Supply KVA 300 kVA Important Safety Instructions Table of Contents Starting and Stopping the UPS Maintaining the UPS System Responding to System Events List of Figures List of Tables Using This Manual IntroductionFor More Information Getting HelpTypical Powerware 9315 UPS System Getting StartedBattery Cabinet Looking Inside the UPSUPS Standard Features Monitor PanelOptions and Accessories Installation FeaturesSafety Considerations Output TransformerSymbols, Controls, and Indicators Risk of Electric ShockUnderstanding UPS Operation Normal Mode Path of Current Through the UPS in Normal ModeBypass Mode Path of Current Through the UPS in Bypass ModeBattery Mode Path of Current Through the UPS in Battery ModeMonitoring and Controlling UPS Operation Control Panel MonitorThis Page Intentionally Left Blank Using the Control Panel Starting and Stopping the UPSTo Place the UPS in Normal Mode To Shut Down the UPS from Normal Mode To Start the UPS in Bypass ModeThis Page Intentionally Left Blank Using the Monitor Panel UPS Monitor PanelUsing the LCD Screen Alarm NoneAdjusting the Contrast Using the PushbuttonsUsing the Load Off Pushbutton Reading the Status Indicators Using the Menu Options · SetupShows the Load Amps Meters screen Shows the Event History Log screen Shows the Active System Events screen Shows the Unit Statistics screen Shows the Mimic screen Time Setup Screen Port Setup Screen Using Features and Options Building Alarm MonitoringSummary Alarm Contacts Summary Alarm ContactsOptional Monitoring Accessories Remote Monitor PanelSystem Normal Battery Cabinets External Battery DisconnectRelay Interface Module Relay Interface ModuleSupervisory Contact Module Shutdown ImminentThis Page Intentionally Left Blank Serial Communications Locating the Communications Panel Communications PanelConnecting Equipment to a Serial Port Port 1 DE-9Port 2 DB-25 Configuring the Serial Ports Setup Serial Port 1 ScreenMode RateDefault Settings Data/StopHandshaking SaveTerminal Mode Printing Selected InformationEntire Log Ctrl + P Event History LogMeters Printout Ctrl + M System Information Printout Ctrl + aBattery Test Printout Ctrl + B APRSystem Configuration Mode Main Menu System ConfigurationProgram Building Alarms Enable/Disable Default Functions Customize Alarm Messages Program Unit NameAdjust Output Voltage Change PasswordBattery Test Setup WK DAY MON Hrmn 4 FRI MARCalibration Mode Computer ModeRemote Monitor Mode Modify Low Battery TimeThis Page Intentionally Left Blank Remote Notification Remote Notification Features Call Answer Description of OperationCall Out Housekeeping Hardware Requirements Configuring the Modem Basic Modem ConfigurationConfiguring the Modem to Call a Remote Computer Configuring the Modem to Call a Numeric Pager Configuring the Modem to Answer Incoming Calls Final Modem Configuration UPS Setup Configuration SaveMessages Alarms User-Selected EventsRectifier Monitor Important Safety Instructions Maintaining the UPS System164201036 Rev. D Performing Preventive Maintenance Maintenance TrainingThis Page Intentionally Left Blank Product Specifications System InputSystem Output Nominal +/-- 5% Environmental Specifications Battery SpecificationsThis Page Intentionally Left Blank System Event Horns Responding to System EventsSystem Event Lights Inverter Messages -- Alarms Inverter Messages -- Notices System Event MessagesInverter Messages Inverter Status Messages Commands Rectifier Status Messages Resetting the UPS System after Load Off Using the Load OFF PushbuttonTo Use the Load OFF Pushbutton This Page Intentionally Left Blank