Powerware 9315 operation manual Inverter Messages Inverter Status Messages Commands

Page 89

INVERTER MESSAGES --

INVERTER STATUS MESSAGES

COMMANDS

 

 

Bypass Mode

Inverter On

Normal Mode

Inverter Off

 

 

Keyswitch On

Battery Contactor (K2) Closed

 

Battery Contactor (K2) Open

 

 

Inverter Commanded On

Total Battery Discharge

Inverter Commanded Off

 

 

 

 

Bypass Contactor (K4) Closed

 

Bypass Contactor (K4) Opened

 

 

 

Input Breaker (CB1) Closed

 

Input Breaker (CB1) Opened

 

 

 

Inverter Contactor (K3) Closed

 

Inverter Contactor (K3) Opened

 

 

 

Inverter Shutdown

 

 

 

Inverter Normal

 

 

 

Load Transferred to Bypass

 

 

 

Auto Mode

 

 

RECTIFIER MESSAGES -- ALARMS

RECTIFIER MESSAGES -- NOTICES

 

 

Rectifier DC Over Voltage

Input AC Over Voltage

Clear Rectifier DC Over Voltage

Clear Input AC Over Voltage

 

 

Rectifier DC Under Voltage

Input AC Under Voltage

Clear Rectifier DC Under Voltage

Clear Input AC Under Voltage

 

 

Rectifier Over Temperature

Input AC Over Frequency

Clear Rectifier Over Temperature

Clear Input AC Over Frequency

 

 

Rct. Over Temperature Warning

Input AC Under Frequency

Clear Rct. Over Temp. Warning

Clear Input AC Under Frequency

 

 

Rct. Temp. Sensor Failure

Rct. Logic Pwr Supply OV

Clear Rct. Temp. Sensor Failure

Clear Rct. Logic Pwr Sply OV

 

 

Rectifier Failure

Rct. Logic Pwr Supply UV

 

Clear Rct. Logic Pwr Sply UV

 

 

Rectifier Alarm

Rectifier DC Too Low

 

 

 

Input Voltage Transient

 

 

 

Rct. Logic Pwr Fail.

 

Clear Rct. Logic Pwr Fail.

 

 

 

Battery Current Limit

 

Clear Battery Current Limit

 

 

 

DC Too High

 

 

Powerware 9315 (200 kVA ---300 kVA) Operation

81

164201036 Rev. D 041500

 

Image 89
Contents Uninterruptible Power Supply KVA 300 kVA Important Safety Instructions Table of Contents Starting and Stopping the UPS Maintaining the UPS System Responding to System Events List of Figures List of Tables Introduction Using This ManualGetting Help For More InformationGetting Started Typical Powerware 9315 UPS SystemLooking Inside the UPS Battery CabinetMonitor Panel UPS Standard FeaturesInstallation Features Options and AccessoriesOutput Transformer Safety ConsiderationsRisk of Electric Shock Symbols, Controls, and IndicatorsUnderstanding UPS Operation Path of Current Through the UPS in Normal Mode Normal ModePath of Current Through the UPS in Bypass Mode Bypass ModePath of Current Through the UPS in Battery Mode Battery ModeControl Panel Monitor Monitoring and Controlling UPS OperationThis Page Intentionally Left Blank Starting and Stopping the UPS Using the Control PanelTo Place the UPS in Normal Mode To Start the UPS in Bypass Mode To Shut Down the UPS from Normal ModeThis Page Intentionally Left Blank UPS Monitor Panel Using the Monitor PanelAlarm None Using the LCD ScreenUsing the Load Off Pushbutton Using the PushbuttonsAdjusting the Contrast Reading the Status Indicators · Setup Using the Menu OptionsShows the Load Amps Meters screen Shows the Event History Log screen Shows the Active System Events screen Shows the Unit Statistics screen Shows the Mimic screen Time Setup Screen Port Setup Screen Building Alarm Monitoring Using Features and OptionsSummary Alarm Contacts Summary Alarm ContactsRemote Monitor Panel Optional Monitoring AccessoriesSystem Normal External Battery Disconnect Battery CabinetsRelay Interface Module Relay Interface ModuleShutdown Imminent Supervisory Contact ModuleThis Page Intentionally Left Blank Serial Communications Communications Panel Locating the Communications PanelPort 1 DE-9 Connecting Equipment to a Serial PortPort 2 DB-25 Setup Serial Port 1 Screen Configuring the Serial PortsRate ModeData/Stop Default SettingsHandshaking SavePrinting Selected Information Terminal ModeEvent History Log Entire Log Ctrl + PSystem Information Printout Ctrl + a Meters Printout Ctrl + MAPR Battery Test Printout Ctrl + BProgram Building Alarms System ConfigurationSystem Configuration Mode Main Menu Enable/Disable Default Functions Program Unit Name Customize Alarm MessagesChange Password Adjust Output VoltageWK DAY MON Hrmn 4 FRI MAR Battery Test SetupComputer Mode Calibration ModeRemote Monitor Mode Modify Low Battery TimeThis Page Intentionally Left Blank Remote Notification Remote Notification Features Call Out Description of OperationCall Answer Housekeeping Hardware Requirements Basic Modem Configuration Configuring the ModemConfiguring the Modem to Call a Remote Computer Configuring the Modem to Call a Numeric Pager Configuring the Modem to Answer Incoming Calls Final Modem Configuration Save UPS Setup ConfigurationUser-Selected Events Messages AlarmsRectifier Monitor Maintaining the UPS System Important Safety Instructions164201036 Rev. D Maintenance Training Performing Preventive MaintenanceThis Page Intentionally Left Blank System Input Product SpecificationsNominal +/-- 5% System OutputBattery Specifications Environmental SpecificationsThis Page Intentionally Left Blank System Event Lights Responding to System EventsSystem Event Horns System Event Messages Inverter Messages -- Alarms Inverter Messages -- NoticesInverter Messages Inverter Status Messages Commands Rectifier Status Messages To Use the Load OFF Pushbutton Using the Load OFF PushbuttonResetting the UPS System after Load Off This Page Intentionally Left Blank