Perle Systems 5500208-41 manual Line Service Commands, Show Line

Page 48

Line Service Commands

Set Termtype

Description Sets the terminal type for the current terminal session. term1, term2, and term3 refer to the user-uploadable custom terminal definitions. If these are not present, the default is wyse60.

User Level Restricted, Normal, Admin

Syntax set termtype [wyse60vt100ansidumbtvi925ibm3151tevt320hp700term1term2 term3]

Option wyse60vt100ansidumbtvi925ibm3151tevt320hp700term1term2term3

Specifies the type of terminal connected to the line:

zDumb

zWYSE60

zVT100

zANSI

zTVI925

zIBM3151TE

zVT320 (specifically supporting VT320-7)

zHP700 (specifically supporting HP700/44)

zTerm1, Term2, Term3 (user defined terminals)

Show Line

Description

Shows the line settings/information.

User Level

Admin

Syntax

show line

Line Service Commands

Set Custom-App

Description

You can create a custom application that can run on a specific serial line in IOLAN

User Level

using the Perle SDK.

Admin

Syntax

set custom-app line .<number>* program-command-line <command>

Options

program-command-line

 

The name of the SDK program executable that has been already been downloaded to

 

the IOLAN, plus any parameters you want to pass to the program. Maximum of 80

 

characters. Use the shell CLI command as described in the SDK Programmer’s Guide

 

to manage the files that you have downloaded to the IOLAN. For example, using

 

sample outraw program, you would type:

 

outraw 192.168.2.1:10001 Acct:10001

 

if you were starting the application on a line.

48

IOLAN DS1/TS2 CLI Reference Guide, Version 4.1

Image 48
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Channel Control Commands GlossaryIolan DS1/TS2 CLI Reference Guide, Version Preface About This BookIntended Audience Contacting Technical Support Making a Technical Support QueryRepair Procedure Feedback on this ManualContacting Technical Support Command Syntax IntroductionIntroduction CLI ConventionsCommand Shortcuts Command OptionsServer Commands Server CommandsSet Custom-App Set ServerBypass-password Dhcp/bootpOem-login Password-limitSet Service TimeoutPrompt-with-name Single-telnetHardware Commands Modbus Commands Set Modbus GatewayTruePort Baud Commands User Level AdminSet TruePort Remap-Baud Show TruePortIPv6 Commands Set IPv6Show IPv6 Add Custom-IPv6 Set Custom-IPv6Range Default 64 method manual Range DefaultDelete Custom-IPv6 Field Format IPv6 address prefix-bits manualIPv6 Commands User Commands Commands for Users Logged Into the IolanMenu PingResume ScreenSet User Set User SessionShow Line Users Syslog ConsoleShow Sessions Show TermtypeTelnet TcpportConfiguring Users Set Default UserVersion Add UserHotkey-prefix LevelLine-access ServiceSess-timer Phone-numberSet User Level Show Default User ConfigureduserShow the settings for the specified user Show the settings for the current userConfiguring Users Line Commands Port vs -Port Line CommandsLine Commands Set LineBreak-delay Dial-timeoutOptions break Break-lengthData-loggin InitialInitiate-connection Internet-addressReset Default Disabled Session stringsDefault 10 ms LockStop-bits Term-typeTerm1, Term2, Term3 user defined terminals User Set Line Interface Set Line Service ConfighostServerport Hostport Set Modem ModemnameInitstring Line Service Commands Show LineSet Telnet-Client Options termtypeSet UDP OutboundportStartipaddress EndipaddressSet Vmodem Set Vmodem-Phone Set Modbus-Slave Line Set Modbus-Master LineIPaddress Set Multihost Line Set Line Initiate-ConnectionShow Interface Show Telnet-ClientShow UDP Show VmodemModem Commands Add ModemDelete Modem Show ModemsPacket Forwarding Commands Set Packet-Forwarding LineEnable-end-trigger1 Enable-end-trigger2Enable-end-eof1 Enable-end-eof2Show Packet-Forwarding Line Packet Forwarding Commands Network Commands Chapter Snmp CommandsAdd Community Add TrapDelete Community Delete TrapSet Snmp Show SnmpTftp Commands Hosts CommandsGateway Commands Show HostsAdd Gateway Delete GatewayDescription Configures the gateway User Level Admin Syntax Set GatewayShow Gateways DestinationipLogging Commands Set SyslogShow Syslog Time Commands Time CommandsTime/Date Setting Commands Show Date Administration Commands Bootup CommandsSet Bootup Show BootupConfiguration file Show ARPTftp File Transfer Commands NetloadHostname/ipaddress FilenameCustom Factory Default Options Factory-default-configNetsave Table or a DNS serverMotd Commands SetSet Motd Show MotdMotd Commands Statistic Commands Chapter Configuration StatisticsShow Netstat Show Modbus StatisticsRun-Time Statistics O Commands Global I/O CommandsSet IO UDP Set IO Temperature-Scale Set LineSet IO Failsafe Set IO ModbusSet IOChannel Mode Set IOChannelSet IOChannel Digital I/O Set IOChannel Digital InputSet IOChannel Digital Input Serial Pins Current status. The default is disabled Set IOChannel Digital OutputDescription can be up to 20 characters Will be displayed as activeActive-signal-width Inactive-signal-widthActive-to-inactive-delay Inactive-to-active-delaySet IOChannel Digital Output Serial Pins Set IOChannel RelayOptions description RelaynumberSet IOChannel Analog True Analog Options analogchannelTrigger-type Trigger-levelClear-mode Clear-levelSet IOChannel Analog Temperature Level Enabled Default Disabled keepaliveSet IOChannel IOExtension Options channelClient-initiated tcp-port Client-initiated multihostServer-initiated tcp-port Local-connection inputchannelSet IOChannel Multihost Show IOChannel StatusKill IOChannel ChannelShow IO Show IOChannelChannel Control Commands Digital OutputDigital Input RelayGlossary