2.3.4JP4 : A/D Trigger Source Selection
Internal Trigger (default)
The OME-A-822PGL/PGH supports two trigger types, internal trigger and external trigger. The external trigger comes from ExtTrg, CN3 pin 17. There are two types of internal triggers, software trigger and pacer trigger. More detailed information is given in section 2.4.8.
2.3.5JP5 : Interrupt Level Selection
NO Interrupt
Interrupt 15 (default)
The interrupt channel can not be shared. The OME-A-822 software driver can support 8 different cards in one system but only 2 of these cards can use the interrupt transfer function.
OME-A-822PGL/PGH Hardware Manual ---- 13