Omega OME-A822PG manual Temperature

Page 63

Where Do I Find Everything I Need for Process Measurement and Control?

OMEGA…Of Course!

Shop online at www.omega.com

TEMPERATURE

 Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies  Wire: Thermocouple, RTD & Thermistor

 Calibrators & Ice Point References

 Recorders, Controllers & Process Monitors  Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

 Transducers & Strain Gages  Load Cells & Pressure Gages  Displacement Transducers  Instrumentation & Accessories

FLOW/LEVEL

 Rotameters, Gas Mass Flowmeters & Flow Computers  Air Velocity Indicators

 Turbine/Paddlewheel Systems  Totalizers & Batch Controllers

pH/CONDUCTIVITY

 pH Electrodes, Testers & Accessories  Benchtop/Laboratory Meters

 Controllers, Calibrators, Simulators & Pumps  Industrial pH & Conductivity Equipment

DATA ACQUISITION

 Data Acquisition & Engineering Software  Communications-Based Acquisition Systems  Plug-in Cards for Apple, IBM & Compatibles  Datalogging Systems

 Recorders, Printers & Plotters

HEATERS

 Heating Cable

 Cartridge & Strip Heaters  Immersion & Band Heaters  Flexible Heaters

 Laboratory Heaters

ENVIRONMENTAL

MONITORING AND CONTROL

 Metering & Control Instrumentation  Refractometers

 Pumps & Tubing

 Air, Soil & Water Monitors

 Industrial Water & Wastewater Treatment

 pH, Conductivity & Dissolved Oxygen Instruments

M4031/0104

Image 63
Contents User’sGuide Czech Republic CanadaMexico BeneluxOME-A-822PGH/PGL Introduction Tables of ContentsConnector General Description Features3 A/D Converter SpecificationsPower Consumption Analog InputsDA Converter Digital I/OInterrupt Channel Direct Memory Access Channel DMA Programmable Timer/CounterProduct Check List ApplicationsBoard Layout Hardware ConfigurationDefault base address is I/O Base Address Setting1 JP1 D/A Internal Reference Voltage Selection Jumper Settings3 JP3 Single-ended/Differential Selection 2 JP2 D/A Int/Ext Ref Voltage Selection5 JP5 Interrupt Level Selection 4 JP4 A/D Trigger Source Selection6 JP6 User Timer/Counter Clock Input Selection DRQ JP7 Dack JP8 DMA 7 JP7 DMA Dack Selection JP8 DMA DRQ SelectionAddress Read Write I/O Register Address1 8254 Counter 2 A/D Input Buffer RegisterConversion is completed, the Ready bit will clear to zero 3 D/A Output Latch Register Clear Interrupt Request 4 D/I Input Buffer RegisterGAIN3 GAIN2 GAIN1 GAIN0 6 A/D Gain Control Register7 A/D Multiplex Control Register OME-A-822PGH Gain Control Code Table8 A/D Mode Control Register 9 A/D Software Trigger Control Register 10 D/O Output Latch Register CN2 Digital I/OCounter 8254 Timer/CounterA/D Conversion Polling, interrupt and DMA 1 A/D conversion flow3 A/D Transfer Modes 2 A/D Conversion Trigger ModesUsing software trigger and polling transfer Delay the settling time refer to Sec .4.6 and SecRefer to Sec D/A Conversion Analog Input Signal Connection OME-A-822PGL/PGH Hardware Manual OME-A-822PGL/PGH Hardware Manual Use a single connection to frame ground not A.GND or D.GND Signal ShieldingUsing OME-DB-8225 CJC Output CN1/CN2/CN3 Pin Assignment CN1 Digital Input Pin AssignmentCN2 Digital Output Pin Assignment SINGLE-ENDED Signal Mode Differential Signals OME-DB-16P Daughter BoardOME-DB-8225 OME-DB-37Description of Variable Resistors CalibrationD/A Calibration A/D Calibration Introduction Diagnostic UtilityOME-A-822PGL/PGH Hardware Manual Running The Diagnostic Utility Base address selection screen SetupDMA no and IRQ no selection screen Calibration Function Test Test Test Screen Digital I/O Test Screen Multiplexer Test Screen Use IRQ Test Screen Use DMA Test Screen DA Gain Test Screen Timer 0 Test Screen Special Test Help WARRANTY/DISCLAIMER Temperature