Omega OME-A822PG manual Diagnostic Utility, Introduction

Page 46

5.Diagnostic Utility

5.1 Introduction

The A82XDIAG.EXE diagnostic utility is a menu-driven program which allows complete testing of the OME-A-822PGL/PGH board. To run the diagnostic utility, change to the subdirectory used in the installation process (C:\OME-A-822 for example). Then type "A82XDIAG" <Enter> to start the application. These steps are shown below:

C:\>CD A822<Enter>

C:\A822>CD DIAG <Enter>

C:\A822\DIAG>A82XDIAG <Enter>

Aconfiguration file, named OME-A-82X.CFG is associated with the A82XDIAG.EXE program.The configu ration of the OME-A-822PGL/PGH board

is stored in this file. The stored information includes the board's I/O base address, interrupt number and DMA channel. Changes are not automatically saved to the configuration file, the user must select the save function to save any changes. When the A82XDIAG.EXE utility starts, it will automatically check if the jumper setting of

the I/O base address matches the value stored in the configuration file. If the addresses do not match, an error message will appear as shown below.

OME-A-822PGL/PGH Hardware Manual ---- 44

Image 46
Contents User’sGuide Benelux CanadaMexico Czech RepublicOME-A-822PGH/PGL Tables of Contents IntroductionConnector Features General DescriptionAnalog Inputs SpecificationsPower Consumption 3 A/D ConverterDigital I/O DA ConverterInterrupt Channel Programmable Timer/Counter Direct Memory Access Channel DMAApplications Product Check ListHardware Configuration Board LayoutI/O Base Address Setting Default base address isJumper Settings 1 JP1 D/A Internal Reference Voltage Selection2 JP2 D/A Int/Ext Ref Voltage Selection 3 JP3 Single-ended/Differential Selection4 JP4 A/D Trigger Source Selection 5 JP5 Interrupt Level Selection6 JP6 User Timer/Counter Clock Input Selection 7 JP7 DMA Dack Selection JP8 DMA DRQ Selection DRQ JP7 Dack JP8 DMAI/O Register Address Address Read Write2 A/D Input Buffer Register 1 8254 CounterConversion is completed, the Ready bit will clear to zero 3 D/A Output Latch Register 4 D/I Input Buffer Register Clear Interrupt Request6 A/D Gain Control Register GAIN3 GAIN2 GAIN1 GAIN0OME-A-822PGH Gain Control Code Table 7 A/D Multiplex Control Register8 A/D Mode Control Register 9 A/D Software Trigger Control Register 10 D/O Output Latch Register Digital I/O CN28254 Timer/Counter CounterA/D Conversion 1 A/D conversion flow Polling, interrupt and DMA2 A/D Conversion Trigger Modes 3 A/D Transfer ModesDelay the settling time refer to Sec .4.6 and Sec Using software trigger and polling transferRefer to Sec D/A Conversion Analog Input Signal Connection OME-A-822PGL/PGH Hardware Manual OME-A-822PGL/PGH Hardware Manual Signal Shielding Use a single connection to frame ground not A.GND or D.GNDUsing OME-DB-8225 CJC Output CN1 Digital Input Pin Assignment CN1/CN2/CN3 Pin AssignmentCN2 Digital Output Pin Assignment SINGLE-ENDED Signal Mode Differential Signals OME-DB-37 Daughter BoardOME-DB-8225 OME-DB-16PCalibration Description of Variable ResistorsD/A Calibration A/D Calibration Diagnostic Utility IntroductionOME-A-822PGL/PGH Hardware Manual Running The Diagnostic Utility Setup Base address selection screenDMA no and IRQ no selection screen Calibration Function Test Test Test Screen Digital I/O Test Screen Multiplexer Test Screen Use IRQ Test Screen Use DMA Test Screen DA Gain Test Screen Timer 0 Test Screen Special Test Help WARRANTY/DISCLAIMER Temperature