Omega Speaker Systems LCIC-WIM-BEN manual Servicing North America

Page 2

OMEGAnet® Online Service

omega.com

Internet e-mail

info@omega.com

 

Servicing North America:

U.S.A.:

One Omega Drive, P.O. Box 4047

ISO 9001 Certified

Stamford, CT 06907-0047

 

TEL: (203) 359-1660

 

FAX: (203) 359-7700

 

e-mail: info@omega.com

Canada:

976 Bergar

 

Laval (Quebec) H7L 5A1, Canada

 

TEL: (514) 856-6928

 

FAX: (514) 856-6886

 

e-mail: info@omega.ca

For immediate technical or application assistance:

U.S.A. and Canada:

Mexico:

Sales Service: 1-800-826-6342/1-800-TC-OMEGA®

Customer Service: 1-800-622-2378/1-800-622-BEST®

Engineering Service: 1-800-872-9436/1-800-USA-WHEN®

En Espan˜ol: (001) 203-359-7803

FAX: (001) 203-359-7807

e-mail: espanol@omega.com info@omega.com.mx

Servicing Europe:

Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic

TEL: +420 (0)59 6311899

FAX: +420 (0)59 6311114

Toll Free: 0800-1-66342

e-mail: info@omegashop.cz

Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany TEL: +49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678

e-mail: info@omega.de

United Kingdom: One Omega Drive, River Bend Technology Centre

ISO 9001 Certified Northbank, Irlam, Manchester M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622

Toll Free in United Kingdom: 0800-488-488

e-mail: sales@omega.co.uk

It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.

The information contained in this document is believed to be correct, but OMEGA accepts

no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.

Image 2
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application Appendices O & the LED DisplayTrouble-shooting Typical Applications IntroductionGeneral Description Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Utilities Setup & RunningRun the setups of the LCIC-WIM utilities in the folders Run a utilityThree stages are Show Data step Calibration UtilityGeneral Pseudo Calibration stepsFive calibration steps are Page Page Page Page Save RestoreCalibrations Library Parameters Calibration Efficiency CE Settings Utility Menu BarTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Port  The address setting takes effect only upon board resetCommunication Baud RateGet results immediately Max Zero Auto ZeroActivate Min ZeroPage Filling Definition FilteringFilter1 Filter2 Decimator Commands Programming your ApplicationGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameters Parameter Parameter Description Data Number TypeBecomes effective only after a system reset either Calibration Name 32 characters max LCIC-WIM ActiveX Start/Stop CommunicationVariables GetVariablerVariable NameVariables Table Category Variable Name Description Get SetVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Filters Parameter that needs no changeFast Mode FilteringLevel IntegerTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Misc Interpreting the data in a blockDigital Inputs Appendix a I/O & the LED DisplayGeneral Notes about the I/O Analog OutputPin Function ConnectionsConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Appendix D USB, RS232 & RS485 Communication ParametersBaud Rate RS485 RS485 Commands Activate address x x=1, 2, 3, …, 62, 63Page Hello Read the RS485 address of the active board Set the specified RS485 addressRS485 Responses Examples Page Page Board selection by the supplied utilities Appendix E Fill Mode IntroductionInput #1 Input #2 Input #3 Input #4 Special ModeHardware Inputs Hardware Outputs Output #1 Output #2 Output #3 Output #4Filling Parameters Filling By WeightFilling By = Weight TimeHi Limit Auto Correction Averaging x last fillingsAuto Tare Activate Lo LimitValid Limits ± … % Valid Results LimitsStart from filling # … Stabilization Criterion Tare & Stop Stabilization Criterion Stop Fast Speed ConfigFilling By = Time Filling Configurations Library Scale of the displayed weight LED Display Notations# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Appendix F Specifications Load Cell InputAppendix G Trouble-shooting Card does not respond after PC power-onManual Zero Appendix H Zero & TareZero function Auto-Tarefunction ParameterWARRANTY/DISCLAIMER Temperature