D.2 Baud Rate

For the USB, the maximal baud rate is 921,600. The board responds well without a need to pre-define the used b/r.

For serial communication, the required b/r should be pre-defined by the user via the Settings utility (section 3.3). The available baud rates are between 19,200 and 115,200. The current b/r used by the board for the serial communication is shown for a while on the LED display upon card reset, prefixed by ‘Sb’ (=Serial baud rate). Refer also to sections 3.3.1.2 & 3.3.2.1.2.

D.3 General RS232 Terminal

You may talk with the card either by your own application or by a general RS232 terminal. One simple one called Termite is available for free at http://www.compuphase.com/software_termite.htm

D.4 Serial Communication & PC Power On/Off

After PC power on or off the serial communication (RS232/RS485) is likely to drop. A card reset is needed in this case.

56

Image 57
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application O & the LED Display AppendicesTrouble-shooting Introduction General DescriptionTypical Applications Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Run the setups of the LCIC-WIM utilities in the folders Setup & RunningUtilities Run a utilityGeneral Calibration UtilityThree stages are Show Data step Pseudo Calibration stepsFive calibration steps are Page Page Page Page Restore Calibrations LibrarySave Parameters Calibration Efficiency CE Menu Bar Settings UtilityTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Communication  The address setting takes effect only upon board resetPort Baud RateGet results immediately Activate Auto ZeroMax Zero Min ZeroPage Filtering Filter1 Filter2 DecimatorFilling Definition Programming your Application CommandsGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameter Parameter Description Data Number Type ParametersBecomes effective only after a system reset either Calibration Name 32 characters max Start/Stop Communication LCIC-WIM ActiveXGetVariablerVariable Name VariablesCategory Variable Name Description Get Set Variables TableVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Parameter that needs no change FiltersFilteringLevel Integer Fast ModeTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Interpreting the data in a block MiscGeneral Notes about the I/O Appendix a I/O & the LED DisplayDigital Inputs Analog OutputConnections Pin FunctionConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Communication Parameters Appendix D USB, RS232 & RS485Baud Rate RS485 Activate address x x=1, 2, 3, …, 62, 63 RS485 CommandsPage Hello Set the specified RS485 address Read the RS485 address of the active boardRS485 Responses Examples Page Page Board selection by the supplied utilities Introduction Appendix E Fill ModeSpecial Mode Hardware InputsInput #1 Input #2 Input #3 Input #4 Output #1 Output #2 Output #3 Output #4 Hardware OutputsFilling By = Weight Filling By WeightFilling Parameters TimeAuto Tare Activate Auto Correction Averaging x last fillingsHi Limit Lo LimitValid Results Limits Start from filling # …Valid Limits ± … % Stabilization Criterion Tare & Stop Fast Speed Config Filling By = TimeStabilization Criterion Stop Filling Configurations Library LED Display Notations Scale of the displayed weight# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Load Cell Input Appendix F SpecificationsCard does not respond after PC power-on Appendix G Trouble-shootingAppendix H Zero & Tare Zero functionManual Zero Parameter Auto-TarefunctionWARRANTY/DISCLAIMER Temperature