Omega Speaker Systems LCIC-WIM-BEN Parameters, Parameter Parameter Description Data Number Type

Page 35

4.2 Parameters

Parameter

Parameter Description

 

Data

number

 

Type

 

 

 

1

Load Cell mV/V (1, 2 or 3. 0 = unknown).

Float

2

Units: 0=g, 1=kg, 2=ton, 3=oz, 4=lb.

Float

3

Full Load Cell(s) Capacity

Float

4

Maximum Applied Capacity

Float

5

Resolution Index (0-17)

 

 

Resolution Index is actually the index to an array of 18

 

 

defined values(0-17) like that:

 

 

0.0001,

0.0002, 0.0005,

 

 

0.001,

0.002,

0.005,

 

 

0.01,

0.02,

0.05,

Float

 

0.1,

0.2,

0.5,

 

 

1,

2,

5,

 

 

10,

20,

50.

 

 

E.g., if Resolution Index=8, then system resolution =

 

 

 

 

0.05.

 

8

Calibration Date formatted as "MMDDYY".

Float

 

So, 10107 <= Calibration Date <= 123199.

 

 

11

Calibration Time formatted as "HHMM".

Float

 

So, 0 <= Calibration Time <=2359

 

 

20

Auto transmit interval (3-52734, integer).

 

 

How many internal adc updates (52734 Hz) there are

 

 

between auto transmissions.

 

 

 

 

This gives a theoretical reading rate from 17578 per

 

 

sec to 1 per sec. (i.e. rate=52734/P20). Practically, the

 

 

actual rate for low values of P20 is usually less than

Float

 

the theoretical rate. (“P20” stands for “Parameter

 

 

 

 

 

#20”.) Note that this rate relates to USB

 

 

 

communication; upon using a serial port, the rate is far

 

 

smaller.

 

 

 

 

Becomes effective only after a system reset (either

 

 

power off/on or using the ‘S’ command).

 

34

Image 35
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application O & the LED Display AppendicesTrouble-shooting Typical Applications IntroductionGeneral Description Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Run a utility Setup & RunningRun the setups of the LCIC-WIM utilities in the folders UtilitiesPseudo Calibration steps Calibration UtilityGeneral Three stages are Show Data stepFive calibration steps are Page Page Page Page Save RestoreCalibrations Library Parameters Calibration Efficiency CE Menu Bar Settings UtilityTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Baud Rate  The address setting takes effect only upon board resetCommunication PortGet results immediately Min Zero Auto ZeroActivate Max ZeroPage Filling Definition FilteringFilter1 Filter2 Decimator Programming your Application CommandsGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameter Parameter Description Data Number Type ParametersBecomes effective only after a system reset either Calibration Name 32 characters max Start/Stop Communication LCIC-WIM ActiveXGetVariablerVariable Name VariablesCategory Variable Name Description Get Set Variables TableVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Parameter that needs no change FiltersFilteringLevel Integer Fast ModeTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Interpreting the data in a block MiscAnalog Output Appendix a I/O & the LED DisplayGeneral Notes about the I/O Digital InputsConnections Pin FunctionConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Communication Parameters Appendix D USB, RS232 & RS485Baud Rate RS485 Activate address x x=1, 2, 3, …, 62, 63 RS485 CommandsPage Hello Set the specified RS485 address Read the RS485 address of the active boardRS485 Responses Examples Page Page Board selection by the supplied utilities Introduction Appendix E Fill ModeInput #1 Input #2 Input #3 Input #4 Special ModeHardware Inputs Output #1 Output #2 Output #3 Output #4 Hardware OutputsTime Filling By WeightFilling By = Weight Filling ParametersLo Limit Auto Correction Averaging x last fillingsAuto Tare Activate Hi LimitValid Limits ± … % Valid Results LimitsStart from filling # … Stabilization Criterion Tare & Stop Stabilization Criterion Stop Fast Speed ConfigFilling By = Time Filling Configurations Library LED Display Notations Scale of the displayed weight# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Load Cell Input Appendix F SpecificationsCard does not respond after PC power-on Appendix G Trouble-shootingManual Zero Appendix H Zero & TareZero function Parameter Auto-TarefunctionWARRANTY/DISCLAIMER Temperature