Variables Table (cont’d)
Category | Variable Name | Description | Get | Set | |
| Weight_Native | Current weight after Filter2, | V |
| |
| not rounded. |
| |||
|
|
|
| ||
| Weight_Rounded | Current weight after Filter2, | V |
| |
Analog | rounded to resolution. |
| |||
|
|
| |||
Inputs | A2D_F1 | Current A/D after Filter1. | V |
| |
| A2D_F2 | Current A/D after Filter2. | V |
| |
| Temperature | The temperature measured on | V |
| |
| the board (°C). |
| |||
|
|
|
| ||
| Output_1_Mode | 0 = Manual, | V | V | |
| Output_2_Mode | V | V | ||
| Output_3_Mode | 1 = General Setpoint. | V | V | |
| Output_4_Mode |
| V | V | |
| Output_1_Status | 0 = off, 1 = on. | V | * | |
Digital | Output_2_Status | * The ‘Set’ is relevant only if | V | * | |
Outputs | Output_3_Status | the corresponding | V | * | |
| Output_4_Status | Output_x_Mode is ‘Manual’. | V | * | |
|
| Status of all outputs at once: |
|
| |
| Output_A_Status | #4#3#2#1 | V |
| |
| #x = Status of output x: |
| |||
|
|
|
| ||
|
| 0 = off, 1 = on (e.g., 0101). |
|
| |
| Setpoint_1 | The weight limit for output x. | V | V | |
General | Setpoint_2 | Relevant only if the | V | V | |
Setpoint_3 | corresponding Output_x_Mode | V | V | ||
Setpoints |
| is |
|
| |
Setpoint_4 | V | V | |||
| ‘General Setpoint’. | ||||
|
| Irrelevant in Fill mode. |
|
|
40