i. Misc.:

 

Manually zero the gross weight. The effect of this function

z (lower case z)

is temporary — it expires upon card reset.

Response (versions 1.12, 3.09, 6.01, 7.00 and up):

 

 

‘z’<c/r>.

Z (Upper case Z)

Cancel the manual zero operation (the lower case ‘z’).

(versions 1.12, 3.09,

That is, return to the original calibration zero.

6.01, 7.00 and up)

Response: ‘Z’<c/r>.

 

System reset (software reset to perform a restart as if

 

turned off/on).

 

Response (versions 1.12, 3.09, 6.01, 7.00 and up):

 

‘S’<c/r> - possibly followed by additional binary

 

character(s).

S

Wait 6 seconds before accessing the board again.

 

(upper case S)

Issue this command after changing any of the following

 

 

parameters:

 

* Auto transmit interval (parameter #20).

 

* Filters & Decimators (parameters #23-25).

 

* General Setpoints (parameters #101-104).

 

* Output modes (parameters #111-114).

F (upper case F)

Start Fill-mode.

 

Get version no. of DSP software.

V (upper case V)

Board’s response: LCIC-WIM/V#.##”, where

 

#.## = Version Number.

32

Image 33
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application O & the LED Display AppendicesTrouble-shooting Introduction General DescriptionTypical Applications Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Run the setups of the LCIC-WIM utilities in the folders Setup & RunningUtilities Run a utilityGeneral Calibration UtilityThree stages are Show Data step Pseudo Calibration stepsFive calibration steps are Page Page Page Page Restore Calibrations LibrarySave Parameters Calibration Efficiency CE Menu Bar Settings UtilityTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Communication  The address setting takes effect only upon board resetPort Baud RateGet results immediately Activate Auto ZeroMax Zero Min ZeroPage Filtering Filter1 Filter2 DecimatorFilling Definition Programming your Application CommandsGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameter Parameter Description Data Number Type ParametersBecomes effective only after a system reset either Calibration Name 32 characters max Start/Stop Communication LCIC-WIM ActiveXGetVariablerVariable Name VariablesCategory Variable Name Description Get Set Variables TableVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Parameter that needs no change FiltersFilteringLevel Integer Fast ModeTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Interpreting the data in a block MiscGeneral Notes about the I/O Appendix a I/O & the LED DisplayDigital Inputs Analog OutputConnections Pin FunctionConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Communication Parameters Appendix D USB, RS232 & RS485Baud Rate RS485 Activate address x x=1, 2, 3, …, 62, 63 RS485 CommandsPage Hello Set the specified RS485 address Read the RS485 address of the active boardRS485 Responses Examples Page Page Board selection by the supplied utilities Introduction Appendix E Fill ModeSpecial Mode Hardware InputsInput #1 Input #2 Input #3 Input #4 Output #1 Output #2 Output #3 Output #4 Hardware OutputsFilling By = Weight Filling By WeightFilling Parameters TimeAuto Tare Activate Auto Correction Averaging x last fillingsHi Limit Lo LimitValid Results Limits Start from filling # …Valid Limits ± … % Stabilization Criterion Tare & Stop Fast Speed Config Filling By = TimeStabilization Criterion Stop Filling Configurations Library LED Display Notations Scale of the displayed weight# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Load Cell Input Appendix F SpecificationsCard does not respond after PC power-on Appendix G Trouble-shootingAppendix H Zero & Tare Zero functionManual Zero Parameter Auto-TarefunctionWARRANTY/DISCLAIMER Temperature