E.4.4 The Filling Configurations Library

There is a ‘Filling Configurations Library’ in which you may save sets of filling configuration parameters. This is useful in case you have more than one type of filling, letting you switch easily and reliably from one configuration to another.

(Note: This library has nothing to do with the calibration library mentioned in section 3.2.2.)

Refer to the ‘Library’ box.

Save

If you like your configuration to be saved in the library, specify a Library Name and check the option box. (It is recommended to specify a meaningful Library Name so that later you’ll recognize the various files you created in the library.) Your filling configuration will be saved in the library only upon clicking the ‘Save to Board’ button. In case a library file having the name you specified already exists, you’ll have to select either to overwrite it, or to use another name.

Recall or Delete a File in the Library

Click the Select button in order to select a file to be recalled or deleted. You may watch the various files and their contents. In order to delete a file, click the Delete button. The procedure to recall a file has two or three steps:

1.Click the Confirm button. This will insert file’s parameters to the 'Filling Definition' box.

2.Optionally, you may modify some of the parameters, thus using the library file as a draft to make your changes easier. In case you want the new values to be saved in a file (either the original one or another), make sure to check the option in the ‘Library’ box.

3.Click the ‘Save to Board’ button.

75

Image 76
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application Appendices O & the LED DisplayTrouble-shooting General Description IntroductionTypical Applications Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Setup & Running Run the setups of the LCIC-WIM utilities in the foldersUtilities Run a utilityCalibration Utility GeneralThree stages are Show Data step Pseudo Calibration stepsFive calibration steps are Page Page Page Page Calibrations Library RestoreSave Parameters Calibration Efficiency CE Settings Utility Menu BarTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints  The address setting takes effect only upon board reset CommunicationPort Baud RateGet results immediately Auto Zero ActivateMax Zero Min ZeroPage Filter1 Filter2 Decimator FilteringFilling Definition Commands Programming your ApplicationGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameters Parameter Parameter Description Data Number TypeBecomes effective only after a system reset either Calibration Name 32 characters max LCIC-WIM ActiveX Start/Stop CommunicationVariables GetVariablerVariable NameVariables Table Category Variable Name Description Get SetVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Filters Parameter that needs no changeFast Mode FilteringLevel IntegerTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Misc Interpreting the data in a blockAppendix a I/O & the LED Display General Notes about the I/ODigital Inputs Analog OutputPin Function ConnectionsConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Appendix D USB, RS232 & RS485 Communication ParametersBaud Rate RS485 RS485 Commands Activate address x x=1, 2, 3, …, 62, 63Page Hello Read the RS485 address of the active board Set the specified RS485 addressRS485 Responses Examples Page Page Board selection by the supplied utilities Appendix E Fill Mode IntroductionHardware Inputs Special ModeInput #1 Input #2 Input #3 Input #4 Hardware Outputs Output #1 Output #2 Output #3 Output #4Filling By Weight Filling By = WeightFilling Parameters TimeAuto Correction Averaging x last fillings Auto Tare ActivateHi Limit Lo LimitStart from filling # … Valid Results LimitsValid Limits ± … % Stabilization Criterion Tare & Stop Filling By = Time Fast Speed ConfigStabilization Criterion Stop Filling Configurations Library Scale of the displayed weight LED Display Notations# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Appendix F Specifications Load Cell InputAppendix G Trouble-shooting Card does not respond after PC power-onZero function Appendix H Zero & TareManual Zero Auto-Tarefunction ParameterWARRANTY/DISCLAIMER Temperature